Comparison of corneal astigmatism and axis location in cataract patients measured by total corneal power, automated keratometry, and simulated keratometry
Authors:
- SoeharnilaSOSoeharnila
- Chareenun ChirapapaisanCCChareenun Chirapapaisan
- Pratuangsri ChonpimaiPCPratuangsri Chonpimai
- 1 December 2012
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 38 (12) , 2088-2093
Abstract
To compare the corneal astigmatism (magnitude and axis location) derived by total corneal power (TCP), automated keratometry, and simulated keratometry. Siriraj Hospital, Mahidol University, Bangkok, Thailand. Prospective comparative study. Eyes with previous ocular surgery or abnormalities were excluded. All patients were examined with the ARK 730A autokeratometer and the Galilei analyzer. The steepest and flattest corneal power along with the steepest axis of the TCP, automated keratometry, and simulated keratometry were recorded. Vector analysis (J0 and J45) was calculated. Analysis of variance with Bonferroni correction was performed for multiple comparisons. Outcome measures were the magnitude and axis location of astigmatism. One hundred eyes of 100 cataract patients were randomly selected. There was no statistically significant difference in the mean steepest axis between TCP (93.31 ± 68.75 [SD]), automated keratometry (94.24 ± 64.78), and simulated keratometry (92.42 ± 64.30). However, the mean magnitude of astigmatism measured by TCP (1.23 ± 0.75) was significantly higher than that measured by automated keratometry (0.93 ± 0.68) (P=.01) but not than that measured by simulated keratometry (1.08 ± 0.68) (P=.43); there was no statistically significant difference in J0 or J45. Twenty two (40%) of 54 eyes with more than 1.00 diopter of TCP astigmatism had more than 10 degrees of axis difference from automated keratometry. The magnitude of TCP astigmatism was higher than that of automated keratometry. The axis location was similar. However, there was more than 10 degrees of axis difference between automated keratometry and TCP in patients with high astigmatism. No author has a financial or proprietary interest in any material or method mentioned.Keywords
This publication has 20 references indexed in Scilit:
- Comparison of corneal power, corneal astigmatism, and axis location in normal eyes obtained from an autokeratometer and a corneal topographerJournal of Cataract & Refractive Surgery, 2012
- Prevalence of corneal astigmatism in patients having routine cataract surgery at a teaching hospital in the United KingdomJournal of Cataract & Refractive Surgery, 2011
- Analysis of biometry and prevalence data for corneal astigmatism in 23 239 eyesJournal of Cataract & Refractive Surgery, 2010
- Estimation accuracy of surgically induced astigmatism on the cornea when neglecting the posterior corneal surface measurementActa Ophthalmologica, 2009
- Agreement Between Pentacam and Videokeratography in Corneal Power AssessmentJournal of Refractive Surgery, 2009
- Accuracy of Corneal Astigmatism Estimation by Neglecting the Posterior Corneal Surface MeasurementAmerican Journal of Ophthalmology, 2009
- Scheimpflug photography keratometry readings for routine intraocular lens power calculationJournal of Cataract & Refractive Surgery, 2009
- Expected effects of surgically induced astigmatism on AcrySof toric intraocular lens resultsJournal of Cataract & Refractive Surgery, 2008
- Evaluation of Normal Corneas Using the Scanning-Slit Topography/Pachymetry SystemCornea, 2004
- Accuracy of Orbscan total optical power maps in detecting refractive change after myopic laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 1999