The out-of-plane contact shield and mA-modulation – the effect on fetal absorbed dose
Open Access
- 11 October 2024
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 200 (19) , 1945-1949
Abstract
The effect of patient shielding on fetal radiation dose was evaluated in computed tomography pulmonary angiography with the out-of-plane shield visible in the localizer but absent in the scan range in chest computed tomography (CT). An anthropomorphic phantom with additional prosthetic pregnancy belly was scanned with different CT scanners using clinical imaging protocols and radiophotoluminescence dosemeters (GD-352 M). The out-of-plane shield decreased the fetal absorbed radiation dose with Siemens Somatom go.Up, Canon Aquilion Prime SP and Canon Aquilion One scanners. The decrease was 3.9%–39.4% (0.01–0.09 mGy). With GE Optima the shield increased the fetal dose by 100% (0.23 mGy), with Canon Aquilion One and GE Optima scanners the abdomen dose increase was 17.5% and 36.4%, respectively (0.61 and 1.38 mGy). Applying an out-of-plane shield outside the scanned volume may increase the fetal radiation dose during CT when using tube current modulation, depending on the make and model of the CT scanner.Keywords
Funding Information
- State Research Funding of the Turku University Hospital
This publication has 20 references indexed in Scilit:
- To shield or not to shield: shielding may have unintended effects on patient dose in CTEuropean Radiology, 2023
- Dose length product to effective dose coefficients in childrenPediatric Radiology, 2023
- Comparison of Guidelines for Evaluation of Suspected Pulmonary Embolism in PregnancyChest, 2022
- European consensus on patient contact shieldingPhysica Medica, 2022
- The use of out-of-plane high Z patient shielding for fetal dose reduction in computed tomography: Literature review and comparison with Monte-Carlo calculations of an alternative optimisation techniquePhysica Medica, 2018
- Fetal radiation dose in three common CT examinations during pregnancy – Monte Carlo studyPhysica Medica, 2017
- ICRP Publication 121: Radiological Protection in Paediatric Diagnostic and Interventional RadiologyAnnals of the ICRP, 2013
- Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort studyThe Lancet, 2012
- Imaging for suspected pulmonary embolism in pregnancy—what about the fetal dose? A comprehensive review of the literatureInsights into Imaging, 2010
- Pulmonary embolism in pregnancyThe Lancet, 2010