Heli Riitta Sinikka Larjava
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Heli Riitta Sinikka Larjava has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
Joanna Sierpowska
Department of Medical Imaging, North Karelia Central Hospital, Wellbeing Services County of North Karelia—Siun Sote , Rinnekatu 10, 80210 Joensuu
3 shared publicationsAntti Kivelä
Department of Radiology, Imaging Centre, Kuopio University Hospital, Kuopio, 70210 Finland
2 shared publicationsEini Niskanen
Department of Radiology, Vaasa Central Hospital , Hietalahdenkatu 4, 65100 Vaasa
2 shared publicationsElina Hallinen
STUK - Radiation and Nuclear Safety Authority, Helsinki, 00880 Finland
2 shared publicationsHannu Järvinen
STUK - Radiation and Nuclear Safety Authority, Helsinki, 00880 Finland
2 shared publicationsJukka Järvinen
Department of Medical Physics, Turku University Hospital and University of Turku , Kiinamyllynkatu 4-8, 20520 Turku
2 shared publications
Latest Publications
- Open Access
- 21 October 2026
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
A patient contact shield visible in the localizer—the effects to tube current modulation
An anthropomorphic phantom was scanned with Siemens Somatom computed tomography scanners using tube current modulation (TCM). Thorax of the phantom was first scanned without the use of a contact shield, followed by a scan with a 0.5 mm lead equivalent out-of-plane shield placed in the localizer but 1 cm caudally outside the scanned volume. Scans were repeated using the scanner’s organ radiation dose reduction feature. Pitch values 0.35, 0.6, and 1.05 were used. With a pitch of 1.05, the effects of TCM varied between scanners from 4.35% to 356% when scanning toward the caudal end of the scanned volume, when shield was used outside the scanned volume. Also, with some scanners, the use of XCare increased the cumulative tube current.
- 21 October 2026
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
Open AccessA patient contact shield visible in the localizer—the effects to tube current modulation
An anthropomorphic phantom was scanned with Siemens Somatom computed tomography scanners using tube current modulation (TCM). Thorax of the phantom was first scanned without the use of a contact shield, followed by a scan with a 0.5 mm lead equivalent out-of-plane shield placed in the localizer but 1 cm caudally outside the scanned volume. Scans were repeated using the scanner’s organ radiation dose reduction feature. Pitch values 0.35, 0.6, and 1.05 were used. With a pitch of 1.05, the effects of TCM varied between scanners from 4.35% to 356% when scanning toward the caudal end of the scanned volume, when shield was used outside the scanned volume. Also, with some scanners, the use of XCare increased the cumulative tube current.
- Open Access
- 15 September 2026
- Published by Royal Society of Chemistry (RSC) in Biomaterials Science
- Vol. 14 (18) , 4863-4874
Using NIR-emitting MgO:Li,Ce,Sm microparticles in the preparation of biophotonic glass – a promising approach to enable optical NIR imaging
Biophotonic implant material allows simultaneous optical and X-ray imaging enabling tracking of the implant healing process.
- 15 September 2026
- Published by Royal Society of Chemistry (RSC) in Biomaterials Science
- Vol. 14 (18) , 4863-4874
Open AccessUsing NIR-emitting MgO:Li,Ce,Sm microparticles in the preparation of biophotonic glass – a promising approach to enable optical NIR imaging
Biophotonic implant material allows simultaneous optical and X-ray imaging enabling tracking of the implant healing process.
- Open Access
- 11 October 2024
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 200 (19) , 1945-1949
The out-of-plane contact shield and mA-modulation – the effect on fetal absorbed dose
The effect of patient shielding on fetal radiation dose was evaluated in computed tomography pulmonary angiography with the out-of-plane shield visible in the localizer but absent in the scan range in chest computed tomography (CT). An anthropomorphic phantom with additional prosthetic pregnancy belly was scanned with different CT scanners using clinical imaging protocols and radiophotoluminescence dosemeters (GD-352 M). The out-of-plane shield decreased the fetal absorbed radiation dose with Siemens Somatom go.Up, Canon Aquilion Prime SP and Canon Aquilion One scanners. The decrease was 3.9%–39.4% (0.01–0.09 mGy). With GE Optima the shield increased the fetal dose by 100% (0.23 mGy), with Canon Aquilion One and GE Optima scanners the abdomen dose increase was 17.5% and 36.4%, respectively (0.61 and 1.38 mGy). Applying an out-of-plane shield outside the scanned volume may increase the fetal radiation dose during CT when using tube current modulation, depending on the make and model of the CT scanner.
- 11 October 2024
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 200 (19) , 1945-1949
Open AccessThe out-of-plane contact shield and mA-modulation – the effect on fetal absorbed dose
The effect of patient shielding on fetal radiation dose was evaluated in computed tomography pulmonary angiography with the out-of-plane shield visible in the localizer but absent in the scan range in chest computed tomography (CT). An anthropomorphic phantom with additional prosthetic pregnancy belly was scanned with different CT scanners using clinical imaging protocols and radiophotoluminescence dosemeters (GD-352 M). The out-of-plane shield decreased the fetal absorbed radiation dose with Siemens Somatom go.Up, Canon Aquilion Prime SP and Canon Aquilion One scanners. The decrease was 3.9%–39.4% (0.01–0.09 mGy). With GE Optima the shield increased the fetal dose by 100% (0.23 mGy), with Canon Aquilion One and GE Optima scanners the abdomen dose increase was 17.5% and 36.4%, respectively (0.61 and 1.38 mGy). Applying an out-of-plane shield outside the scanned volume may increase the fetal radiation dose during CT when using tube current modulation, depending on the make and model of the CT scanner.
- Open Access
- 14 September 2023
- Published by Springer Nature in European Radiology
- Vol. 34 (4) , 2480-2486
To shield or not to shield: shielding may have unintended effects on patient dose in CT
Objectives: The aim of the patient out-of-plane shield is to reduce the patient radiation dose. Its effect on tube current modulation was evaluated with the out-of-plane shield visible in the localizer but absent in the scan range in chest CT with different CT scanners. Methods: An anthropomorphic phantom was scanned with six different CT scanners from three different vendors. The chest was first scanned without any shielding, and then with the out-of-plane shield within the localizer but outside the imaged volume. All pitch values of each scanner were used. The tube current values with and without the out-of-plane shield were collected and used to evaluate the effect of overscanning and tube current modulation (TCM) on patient radiation dose. Results: The highest increase in cumulative mA was 217%, when the pitch was 1.531. The tube current value increased already 8.9 cm before the end of the scanned anatomy and the difference between the tube current of the last slices (with and without the out-of-plane shield in the localizer) was 976%. Conclusion: Applying an out-of-plane shield outside the scanned volume but visible in the localizer images may increase the patient dose considerably if the scanner’s TCM function is based only on localizer images. Clinical relevance statement: The use of an out-of-plane shield in CT may strongly increase the tube current modulation and thus provide the patient with a higher radiation dose. Key Points: • Applying an out-of-plane shield outside the scanned volume but visible in the localizer images may increase patient radiation dose considerably. • The effect is visible with scanners that use solely localizer-based tube current modulation. • Features like overscanning may be difficult for the user to notice when planning the scanning, and yet they may affect tube current modulation and through it to patient dose.
- 14 September 2023
- Published by Springer Nature in European Radiology
- Vol. 34 (4) , 2480-2486
Open AccessTo shield or not to shield: shielding may have unintended effects on patient dose in CT
Objectives: The aim of the patient out-of-plane shield is to reduce the patient radiation dose. Its effect on tube current modulation was evaluated with the out-of-plane shield visible in the localizer but absent in the scan range in chest CT with different CT scanners. Methods: An anthropomorphic phantom was scanned with six different CT scanners from three different vendors. The chest was first scanned without any shielding, and then with the out-of-plane shield within the localizer but outside the imaged volume. All pitch values of each scanner were used. The tube current values with and without the out-of-plane shield were collected and used to evaluate the effect of overscanning and tube current modulation (TCM) on patient radiation dose. Results: The highest increase in cumulative mA was 217%, when the pitch was 1.531. The tube current value increased already 8.9 cm before the end of the scanned anatomy and the difference between the tube current of the last slices (with and without the out-of-plane shield in the localizer) was 976%. Conclusion: Applying an out-of-plane shield outside the scanned volume but visible in the localizer images may increase the patient dose considerably if the scanner’s TCM function is based only on localizer images. Clinical relevance statement: The use of an out-of-plane shield in CT may strongly increase the tube current modulation and thus provide the patient with a higher radiation dose. Key Points: • Applying an out-of-plane shield outside the scanned volume but visible in the localizer images may increase patient radiation dose considerably. • The effect is visible with scanners that use solely localizer-based tube current modulation. • Features like overscanning may be difficult for the user to notice when planning the scanning, and yet they may affect tube current modulation and through it to patient dose.
- 14 December 2019
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 188 (2) , 181-190
CONTEMPORARY RADIATION DOSES IN INTERVENTIONAL CARDIOLOGY: A NATIONWIDE STUDY OF PATIENT SKIN DOSES IN FINLAND
In contemporary interventional cardiology, for typical elderly patients, the most severe radiation-related harm to patients can be considered to come from skin exposures. In this paper, maximum local skin doses in cardiological procedures are explored with Gafchromic film dosimetry. Film and reader calibrations and reading were performed at the Secondary Standards Dosimetry Laboratory of the Radiation and Nuclear Safety Authority (STUK), and data were gathered from seven hospitals in Finland. As alert levels for early transient erythema, 200 Gycm2 kerma area product (KAP) and 2000 mGy air kerma levels for transcatheter aortic valve implantations (TAVI) procedures are proposed. The largest doses were measured in TAVI (4158.8 mGy) and percutaneous coronary interventions (PCI) (941.68 mGy). Accuracies of the GE DoseWatch and Siemens CareMonitor skin dose estimates were reasonable, but more results are needed to reliably assess and validate the tools’ capabilities and reliabilities. Uncertainty of the Gafchromic dosimetry was estimated as 9.1% for a calibration with seven data points and 19.3% for a calibration with five data points.
- 14 December 2019
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 188 (2) , 181-190
CONTEMPORARY RADIATION DOSES IN INTERVENTIONAL CARDIOLOGY: A NATIONWIDE STUDY OF PATIENT SKIN DOSES IN FINLAND
In contemporary interventional cardiology, for typical elderly patients, the most severe radiation-related harm to patients can be considered to come from skin exposures. In this paper, maximum local skin doses in cardiological procedures are explored with Gafchromic film dosimetry. Film and reader calibrations and reading were performed at the Secondary Standards Dosimetry Laboratory of the Radiation and Nuclear Safety Authority (STUK), and data were gathered from seven hospitals in Finland. As alert levels for early transient erythema, 200 Gycm2 kerma area product (KAP) and 2000 mGy air kerma levels for transcatheter aortic valve implantations (TAVI) procedures are proposed. The largest doses were measured in TAVI (4158.8 mGy) and percutaneous coronary interventions (PCI) (941.68 mGy). Accuracies of the GE DoseWatch and Siemens CareMonitor skin dose estimates were reasonable, but more results are needed to reliably assess and validate the tools’ capabilities and reliabilities. Uncertainty of the Gafchromic dosimetry was estimated as 9.1% for a calibration with seven data points and 19.3% for a calibration with five data points.
- 15 November 2019
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 188 (1) , 73-78
INTRAOPERATIVE CHOLANGIOGRAPHY DURING CHOLECYSTECTOMY RESULTS IN LOW EXPOSURE TO RADIATION: A RETROSPECTIVE COHORT STUDY
This study aimed to determine the exposure to radiation delivered to the patient during routine intraoperative cholangiography (IOC) in cholecystectomy and examine the factors affecting radiation dose and fluoroscopy time (FT). From January 2016 to December 2017, 598 IOC examinations were performed. This study included 324 intraoperative cholangiographies performed with c-arm equipment not exceeding 10 years of age. When residents performed the procedures, the mean kerma area product (KAP) was 0.36 (standard deviation [SD] 0.70) Gycm 2 and in specialist surgeons group 0.36 (SD 0.47) Gycm2, P = 0.47. In residents group, the mean FT was 11.4 (SD 10.1) seconds and in specialist surgeons group, 9.2 (SD 11.9) seconds, P < 0.01. Linear regression analysis showed association between increased KAP-values and the presence of common bile duct (CBD) stones and body mass index (BMI). Age, BMI, laparoscopic surgery, acute cholecystitis, presence of CBD stones, resident surgeon performing IOC and ASA III–IV were associated with higher FT. National diagnostic reference level for IOC has not been introduced in Finland so far. Our mean KAP values (0.36 Gycm2) were 3–4 times lower and FT (10.1 seconds) were 3–5 times lower than the few reported in the literature. Routine use of IOC during cholecystectomy results in relatively low-radiation dose performed either by residents or specialist surgeons, irrespective of whether CBD stones were visualized or not.
- 15 November 2019
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 188 (1) , 73-78
INTRAOPERATIVE CHOLANGIOGRAPHY DURING CHOLECYSTECTOMY RESULTS IN LOW EXPOSURE TO RADIATION: A RETROSPECTIVE COHORT STUDY
This study aimed to determine the exposure to radiation delivered to the patient during routine intraoperative cholangiography (IOC) in cholecystectomy and examine the factors affecting radiation dose and fluoroscopy time (FT). From January 2016 to December 2017, 598 IOC examinations were performed. This study included 324 intraoperative cholangiographies performed with c-arm equipment not exceeding 10 years of age. When residents performed the procedures, the mean kerma area product (KAP) was 0.36 (standard deviation [SD] 0.70) Gycm 2 and in specialist surgeons group 0.36 (SD 0.47) Gycm2, P = 0.47. In residents group, the mean FT was 11.4 (SD 10.1) seconds and in specialist surgeons group, 9.2 (SD 11.9) seconds, P < 0.01. Linear regression analysis showed association between increased KAP-values and the presence of common bile duct (CBD) stones and body mass index (BMI). Age, BMI, laparoscopic surgery, acute cholecystitis, presence of CBD stones, resident surgeon performing IOC and ASA III–IV were associated with higher FT. National diagnostic reference level for IOC has not been introduced in Finland so far. Our mean KAP values (0.36 Gycm2) were 3–4 times lower and FT (10.1 seconds) were 3–5 times lower than the few reported in the literature. Routine use of IOC during cholecystectomy results in relatively low-radiation dose performed either by residents or specialist surgeons, irrespective of whether CBD stones were visualized or not.
- 16 April 2019
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 185 (4) , 483-493
CONTEMPORARY RADIATION DOSES IN INTERVENTIONAL CARDIOLOGY: A NATIONWIDE STUDY OF PATIENT DOSES IN FINLAND
The amount of interventional procedures such as percutaneous coronary intervention (PCI), transcatheter aortic valve implantation (TAVI), pacemaker implantation (PI) and ablations has increased within the previous decade. Simultaneously, novel fluoroscopy mainframes enable lower radiation doses for patients and operators. Therefore, there is a need to update the existing diagnostic reference levels (DRLs) and propose new ones for common or recently introduced procedures. We sought to assess patient radiation doses in interventional cardiology in a large sample from seven hospitals across Finland between 2014 and 2016. Data were used to set updated national DRLs for coronary angiographies (kerma-air product (KAP) 30 Gycm(2)) and PCIs (KAP 75 cm(2)), and novel levels for PIs (KAP 3.5 Gycm(2)), atrial fibrillation ablation procedures (KAP 25 Gycm(2)) and TAVI (KAP 90 Gycm(2)). Tentative KAP values were set for implantations of cardiac resynchronization therapy devices (CRT, KAP 22 Gycm(2)), electrophysiological treatment of atrioventricular nodal re-entry tachycardia (6 Gycm(2)) and atrial flutter procedures (KAP 16 Gycm(2)). The values for TAVI and CRT device implantation are published for the first time on national level. Dose from image acquisition (cine) constitutes the major part of the total dose in coronary and atrial fibrillation ablation procedures. For TAVI, patient weight is a good predictor of patient dose.
- 16 April 2019
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 185 (4) , 483-493
CONTEMPORARY RADIATION DOSES IN INTERVENTIONAL CARDIOLOGY: A NATIONWIDE STUDY OF PATIENT DOSES IN FINLAND
The amount of interventional procedures such as percutaneous coronary intervention (PCI), transcatheter aortic valve implantation (TAVI), pacemaker implantation (PI) and ablations has increased within the previous decade. Simultaneously, novel fluoroscopy mainframes enable lower radiation doses for patients and operators. Therefore, there is a need to update the existing diagnostic reference levels (DRLs) and propose new ones for common or recently introduced procedures. We sought to assess patient radiation doses in interventional cardiology in a large sample from seven hospitals across Finland between 2014 and 2016. Data were used to set updated national DRLs for coronary angiographies (kerma-air product (KAP) 30 Gycm(2)) and PCIs (KAP 75 cm(2)), and novel levels for PIs (KAP 3.5 Gycm(2)), atrial fibrillation ablation procedures (KAP 25 Gycm(2)) and TAVI (KAP 90 Gycm(2)). Tentative KAP values were set for implantations of cardiac resynchronization therapy devices (CRT, KAP 22 Gycm(2)), electrophysiological treatment of atrioventricular nodal re-entry tachycardia (6 Gycm(2)) and atrial flutter procedures (KAP 16 Gycm(2)). The values for TAVI and CRT device implantation are published for the first time on national level. Dose from image acquisition (cine) constitutes the major part of the total dose in coronary and atrial fibrillation ablation procedures. For TAVI, patient weight is a good predictor of patient dose.
- 3 August 2013
- Published by Springer Nature in Skeletal Radiology
- Vol. 42 (11) , 1507-1513
Total ankle arthroplasty: optimizing computed tomography imaging protocol
- 3 August 2013
- Published by Springer Nature in Skeletal Radiology
- Vol. 42 (11) , 1507-1513
Total ankle arthroplasty: optimizing computed tomography imaging protocol