Evaluation of patients with coronary artery disease
Authors:
- 1 January 2013
- journal article
- Published by Georg Thieme Verlag KG in Nuklearmedizin-Nuclear Medicine
- Vol. 52 (05) , 178-185
Abstract
Quantification of myocardial perfusion scintigraphy is often performed to assist physicians in detecting coronary artery disease (CAD). Modern software and hardware packages provide improvements able to shorten scan time and/or reduce administered activity, without compromising image quality in radionuclide myocardial perfusion imaging (MPI). Recently, multifocal collimators were introduced with dedicated reconstruction software, named IQ-SPECT, able to shorten considerably scan time. The aim of our study was to compare this new protocol to the already validated standard ones. Patients, methods: We enrolled 43 patients with suspected or diagnosed CAD. All patients underwent a two-days protocol radionuclide myocardial perfusion scan at rest and after a standard stress test (exercise or dipyridamole) after administering 99mTc-tetrofosmin. Images were acquired on a 2-head gamma camera and reconstructed with attenuation correction. All the images were scored using a 17-segments model by three experienced physicians, blind to clinical data and to acquisition and processing modality. Results, conclusion: No significant differences were recorded in perfusion scores on paired t-test and Wilcoxon among the full-time images reconstructed with standard protocol or IQSPECT, both overall on a 17-segments evaluation and when considering different territories of distribution. MPI with IQ-SPECT protocol can be acquired at about a quarter scan time without disagreement compared to full time scan acquisition performed with standard protocols.Keywords
This publication has 18 references indexed in Scilit:
- Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: first clinical validationEuropean Journal of Nuclear Medicine and Molecular Imaging, 2010
- Wide beam reconstruction “quarter-time” gated myocardial perfusion SPECT functional imaging: a comparison to “full-time” ordered subset expectation maximumJournal of Nuclear Cardiology, 2009
- Prospective multicenter evaluation of rapid, gated SPECT myocardial perfusion upright imagingJournal of Nuclear Cardiology, 2009
- Half-Time SPECT Myocardial Perfusion Imaging with Attenuation CorrectionJournal of Nuclear Medicine, 2009
- Myocardial perfusion and function: Single photon emission computed tomographyJournal of Nuclear Cardiology, 2007
- Radiation Dose to Patients From Cardiac Diagnostic ImagingCirculation, 2007
- 3.09Journal of Nuclear Cardiology, 2007
- A comparison of three radionuclide myocardial perfusion tracers in clinical practice: the ROBUST studyEuropean Journal of Nuclear Medicine and Molecular Imaging, 2002
- Guidelines for Meta-analyses Evaluating Diagnostic TestsAnnals of Internal Medicine, 1994
- Quantitation of size of relative myocardial perfusion defect by single-photon emission computed tomography.Circulation, 1984