Determination of Polarization Resistance of Reinforcement with a Sensorized Guard Ring: Analysis of Errors
Author:
- 1 April 2004
- journal article
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 60 (4) , 414-420
Abstract
Reinforcement corrosion is the main cause of damage to concrete structures. The main source of errors in measuring the corrosion rate of rebars on-site is the unknown and nonuniform current distribution between the small counter electrode on the concrete surface and the large rebar network in reinforced concrete construction. Guard ring electrodes are used in an attempt to confine the excitation current within a defined area, so that errors caused by the nonuniform current distribution along the length of a rebar can be eliminated. To better understand the functioning of sensorized guard electrode (GE), and to assess its effectiveness in eliminating errors due to spread of current signal from the small counter electrode (CE), measurements of the polarization resistance of reinforcement with the use of the sensorized GE device have been numerically simulated. The results indicate that the sensorized GE arrangement is not able to deliver accurate values of the polarization resistance of reinforcement within the whole range of corrosion activity when a constant extent of the CE current spread is used for the calculations. When corrosion is uniform, the current distribution under the sensorized GE is a superposition of both CE and GE currents and depends strongly on testing conditions. As a consequence, the sensorized GE is not able to confine the lateral spread of the CE current within a defined and constant distance from the border of CE (diameter of confinement area). An error of one order of magnitude may be expected when calculating the polarization resistance with an a priori defined and fixed diameter of confinement area for differing test conditions. At high corrosion activity, an “overconfinement” through the GE takes place, and may be a source of serious underestimation of the corrosion rate. When the reinforcement is passive, the corrosion rate is overestimated. When the corrosion is localized, the corrosion rate of the corroding part is seriously underestimated even for a relatively large size of the active spot. This may cause difficulty in differentiating between mild homogeneous corrosion and severe local corrosion.Keywords
This publication has 6 references indexed in Scilit:
- Determination of corrosion rate of reinforcement with a modulated guard ring electrode; analysis of errors due to lateral current distributionCorrosion Science, 2004
- Suitability of Assessment Methods for Identifying Active and Passive Zones in Reinforced ConcreteCorrosion, 1995
- Polarization current distribution and electrochemical impedance response of reinforced concrete when using guard ring electrodesElectrochimica Acta, 1993
- Electrochemical Measurements on Concrete Bridges for Evaluation of Reinforcement Corrosion RatesCorrosion, 1993
- Comparison of Corrosion Rate-Measuring Devices for Determining Corrosion Rate of Steel-in-Concrete SystemsCorrosion, 1992
- Possibilities of the "Guard Ring" for the Confinement of the Electrical Signal in Polarization Measurements of Reinforcements1989