Electron spatially fractionated radiation therapy using a clinically biocompatible 3D‐printed tungsten‐filament GRID
Authors:
Open Access
- 19 April 2026
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (4) , e70567
Abstract
Background: Spatially fractionated radiation therapy (SFRT) can enhance tumor control by delivering high‐dose subvolumes while sparing normal tissue and stimulating antitumor immunity. However, its application to superficial disease through electron beam radiation therapy remains limited. Electron SFRT (eSFRT) could serve as a strategy for initial tumor downsizing of ulcerated cutaneous and subcutaneous tumors by delivering a superficial, spatially heterogeneous dose, enabling subsequent conventional electron therapy to enhance local control. Purpose: To evaluate the dosimetric feasibility of eSFRT using a novel 3D‐printed tungsten‐filament GRID (TS) and compare it to lead sheet (LS) references. Methods: The TS GRID collimators were 3D‐printed from a tungsten alloy filament (91%–93% tungsten by weight, PLA‐based), with a hexagonal array of 27 apertures (1.5 cm diameter, 2.0 cm spacing, 1 mm thickness) in a 10 × 10 cm 2 sheet. LS GRIDs (1.5 and 3.0 mm thick) were used as reference. GRIDs were placed directly on water and anthropomorphic phantoms. Dosimetric measurements for GRID field properties, including percent depth dose (PDD) and crossbeam plane dose profiles at various depths, were performed in a water tank phantom for 6, 9, and 12 MeV electron beams. Key parameters, such as depths of maximum dose (d max ) and doses at 90% (d90) and 50% (d50), were determined. Peak‐to‐valley dose ratios (PVDRs) were also evaluated and compared with data from an anthropomorphic phantom. Results: The TS GRID collimator produced highly heterogeneous superficial dose distributions with PVDR > 2.0 at depths > 10 mm for 6–9 MeV, supporting spatially fractionated dose delivery. PVDR reductions on curved phantom surfaces were minimal (<3%). TS demonstrated reproducible geometry, mechanical stability, and biocompatibility, enabling direct placement on superficial tumors. Compared to previously reported tungsten‐based composite GRID collimators, including tungsten functional paper (TFP) and tungsten‐containing rubber (TCR), TS achieved higher PVDR at clinically relevant depths. LS GRID collimators achieved slightly higher PVDR but are not suitable for clinical use directly on skin. Conclusions: This study demonstrates the feasibility of eSFRT using a 3D‐printed TS GRID collimator to deliver superficial, spatially heterogeneous doses. TS provides reproducible geometry, mechanical stability, and biocompatibility, making it a clinically translatable alternative to lead, TFP, and TCR GRID collimators warranting further preclinical and clinical investigation.Keywords
This publication has 25 references indexed in Scilit:
- Immunologic Consequences of Signal Transducers and Activators of Transcription 3 Activation in Human Squamous Cell CarcinomaCancer Research, 2010
- Review of electron beam therapy physicsPhysics in Medicine & Biology, 2006
- Dosimetric characteristics with spatial fractionation using electron grid therapyMedical Dosimetry, 2002
- Transforming growth factor ß1 and ß2 (TGFβ2 / TGFβ2) profile changes in previously irradiated free flap bedsHead & Neck, 2001
- Surface dose with grids in electron beam radiation therapyApplied Radiation and Isotopes, 2001
- TGF-β1 and radiation fibrosis: a master switch and a specific therapeutic target?International Journal of Radiation Oncology - Biology - Physics (IJROBP), 2000
- AAPM's TG‐51 protocol for clinical reference dosimetry of high‐energy photon and electron beamsMedical Physics, 1999
- Do inflammatory processes contribute to radiation induced erythema observed in the skin of humans?Radiotherapy and Oncology, 1998
- Transforming growth factor beta: a promotor of late connective tissue injury following radiotherapy?British Journal of Radiology, 1990
- Clinical Experience with Irradiation Through a GridRadiology, 1952