Lauren Lukas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lauren Lukas has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Alan Epstein
Department of Pathology, Keck School of Medicine, University of Southern California, Los Angeles, USA
1 shared publicationBrittney Chau
Department of Radiation Oncology Norris Comprehensive Cancer Center University of Southern California Keck School of Medicine Los Angeles California USA
1 shared publicationHualin Zhang
Department of Radiation Oncology Norris Comprehensive Cancer Center University of Southern California Keck School of Medicine Los Angeles California USA
1 shared publication- Hualin Zhang
Radiation Oncology Program, Children's Hospital Los Angeles, Los Angeles, CA, United States
1 shared publication Karen Cheng
Department of Radiation Oncology, Keck School of Medicine, University of Southern California, Los Angeles, USA
1 shared publicationMelody Liu
Department of Radiation Oncology Norris Comprehensive Cancer Center University of Southern California Keck School of Medicine Los Angeles California USA
1 shared publication
Latest Publications
- Open Access
- 19 April 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (4) , e70567
Electron spatially fractionated radiation therapy using a clinically biocompatible 3D‐printed tungsten‐filament GRID
Background: Spatially fractionated radiation therapy (SFRT) can enhance tumor control by delivering high‐dose subvolumes while sparing normal tissue and stimulating antitumor immunity. However, its application to superficial disease through electron beam radiation therapy remains limited. Electron SFRT (eSFRT) could serve as a strategy for initial tumor downsizing of ulcerated cutaneous and subcutaneous tumors by delivering a superficial, spatially heterogeneous dose, enabling subsequent conventional electron therapy to enhance local control. Purpose: To evaluate the dosimetric feasibility of eSFRT using a novel 3D‐printed tungsten‐filament GRID (TS) and compare it to lead sheet (LS) references. Methods: The TS GRID collimators were 3D‐printed from a tungsten alloy filament (91%–93% tungsten by weight, PLA‐based), with a hexagonal array of 27 apertures (1.5 cm diameter, 2.0 cm spacing, 1 mm thickness) in a 10 × 10 cm 2 sheet. LS GRIDs (1.5 and 3.0 mm thick) were used as reference. GRIDs were placed directly on water and anthropomorphic phantoms. Dosimetric measurements for GRID field properties, including percent depth dose (PDD) and crossbeam plane dose profiles at various depths, were performed in a water tank phantom for 6, 9, and 12 MeV electron beams. Key parameters, such as depths of maximum dose (d max ) and doses at 90% (d90) and 50% (d50), were determined. Peak‐to‐valley dose ratios (PVDRs) were also evaluated and compared with data from an anthropomorphic phantom. Results: The TS GRID collimator produced highly heterogeneous superficial dose distributions with PVDR > 2.0 at depths > 10 mm for 6–9 MeV, supporting spatially fractionated dose delivery. PVDR reductions on curved phantom surfaces were minimal (<3%). TS demonstrated reproducible geometry, mechanical stability, and biocompatibility, enabling direct placement on superficial tumors. Compared to previously reported tungsten‐based composite GRID collimators, including tungsten functional paper (TFP) and tungsten‐containing rubber (TCR), TS achieved higher PVDR at clinically relevant depths. LS GRID collimators achieved slightly higher PVDR but are not suitable for clinical use directly on skin. Conclusions: This study demonstrates the feasibility of eSFRT using a 3D‐printed TS GRID collimator to deliver superficial, spatially heterogeneous doses. TS provides reproducible geometry, mechanical stability, and biocompatibility, making it a clinically translatable alternative to lead, TFP, and TCR GRID collimators warranting further preclinical and clinical investigation.
- 19 April 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (4) , e70567
Open AccessElectron spatially fractionated radiation therapy using a clinically biocompatible 3D‐printed tungsten‐filament GRID
Background: Spatially fractionated radiation therapy (SFRT) can enhance tumor control by delivering high‐dose subvolumes while sparing normal tissue and stimulating antitumor immunity. However, its application to superficial disease through electron beam radiation therapy remains limited. Electron SFRT (eSFRT) could serve as a strategy for initial tumor downsizing of ulcerated cutaneous and subcutaneous tumors by delivering a superficial, spatially heterogeneous dose, enabling subsequent conventional electron therapy to enhance local control. Purpose: To evaluate the dosimetric feasibility of eSFRT using a novel 3D‐printed tungsten‐filament GRID (TS) and compare it to lead sheet (LS) references. Methods: The TS GRID collimators were 3D‐printed from a tungsten alloy filament (91%–93% tungsten by weight, PLA‐based), with a hexagonal array of 27 apertures (1.5 cm diameter, 2.0 cm spacing, 1 mm thickness) in a 10 × 10 cm 2 sheet. LS GRIDs (1.5 and 3.0 mm thick) were used as reference. GRIDs were placed directly on water and anthropomorphic phantoms. Dosimetric measurements for GRID field properties, including percent depth dose (PDD) and crossbeam plane dose profiles at various depths, were performed in a water tank phantom for 6, 9, and 12 MeV electron beams. Key parameters, such as depths of maximum dose (d max ) and doses at 90% (d90) and 50% (d50), were determined. Peak‐to‐valley dose ratios (PVDRs) were also evaluated and compared with data from an anthropomorphic phantom. Results: The TS GRID collimator produced highly heterogeneous superficial dose distributions with PVDR > 2.0 at depths > 10 mm for 6–9 MeV, supporting spatially fractionated dose delivery. PVDR reductions on curved phantom surfaces were minimal (<3%). TS demonstrated reproducible geometry, mechanical stability, and biocompatibility, enabling direct placement on superficial tumors. Compared to previously reported tungsten‐based composite GRID collimators, including tungsten functional paper (TFP) and tungsten‐containing rubber (TCR), TS achieved higher PVDR at clinically relevant depths. LS GRID collimators achieved slightly higher PVDR but are not suitable for clinical use directly on skin. Conclusions: This study demonstrates the feasibility of eSFRT using a 3D‐printed TS GRID collimator to deliver superficial, spatially heterogeneous doses. TS provides reproducible geometry, mechanical stability, and biocompatibility, making it a clinically translatable alternative to lead, TFP, and TCR GRID collimators warranting further preclinical and clinical investigation.
- Open Access
- 18 November 2023
- Published by Springer Nature in Current Oncology Reports
- Vol. 25 (12) , 1483-1496
Immune Priming with Spatially Fractionated Radiation Therapy
Purpose of Review: This review aims to summarize the current preclinical and clinical evidence of nontargeted immune effects of spatially fractionated radiation therapy (SFRT). We then highlight strategies to augment the immunomodulatory potential of SFRT in combination with immunotherapy (IT). Recent Findings: The response of cancer to IT is limited by primary and acquired immune resistance, and strategies are needed to prime the immune system to increase the efficacy of IT. Radiation therapy can induce immunologic effects and can potentially be used to synergize the effects of IT, although the optimal combination of radiation and IT is largely unknown. SFRT is a novel radiation technique that limits ablative doses to tumor subvolumes, and this highly heterogeneous dose deposition may increase the immune-rich infiltrate within the targeted tumor with enhanced antigen presentation and activated T cells in nonirradiated tumors. Summary: The understanding of nontargeted effects of SFRT can contribute to future translational strategies to combine SFRT and IT. Integration of SFRT and IT is an innovative approach to address immune resistance to IT with the overall goal of improving the therapeutic ratio of radiation therapy and increasing the efficacy of IT.
- 18 November 2023
- Published by Springer Nature in Current Oncology Reports
- Vol. 25 (12) , 1483-1496
Open AccessImmune Priming with Spatially Fractionated Radiation Therapy
Purpose of Review: This review aims to summarize the current preclinical and clinical evidence of nontargeted immune effects of spatially fractionated radiation therapy (SFRT). We then highlight strategies to augment the immunomodulatory potential of SFRT in combination with immunotherapy (IT). Recent Findings: The response of cancer to IT is limited by primary and acquired immune resistance, and strategies are needed to prime the immune system to increase the efficacy of IT. Radiation therapy can induce immunologic effects and can potentially be used to synergize the effects of IT, although the optimal combination of radiation and IT is largely unknown. SFRT is a novel radiation technique that limits ablative doses to tumor subvolumes, and this highly heterogeneous dose deposition may increase the immune-rich infiltrate within the targeted tumor with enhanced antigen presentation and activated T cells in nonirradiated tumors. Summary: The understanding of nontargeted effects of SFRT can contribute to future translational strategies to combine SFRT and IT. Integration of SFRT and IT is an innovative approach to address immune resistance to IT with the overall goal of improving the therapeutic ratio of radiation therapy and increasing the efficacy of IT.