ISOLATION OF THE BRAIN-RELATED FACTOR OF THE ERROR BETWEEN INTENDED AND ACHIEVED POSITION OF DEEP BRAIN STIMULATION ELECTRODES IMPLANTED INTO THE SUBTHALAMIC NUCLEUS FOR THE TREATMENT OF PARKINSON'S DISEASE
- 1 May 2009
- journal article
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 64 (5) , ons374-ons384
Abstract
Although a few studies have quantified errors in the implantation of deep brain stimulation electrodes into the subthalamic nucleus (STN), a significant trend in error direction has not been reported. We have previously found that an error in axial plane, which is of most concern because it cannot be compensated for during deep brain stimulation programming, had a posteromedial trend. We hypothesized that this trend results from a predominance of a directionally oriented error factor of brain origin. Accordingly, elimination of nonbrain (technical) error factors could augment this trend. Thus, implantation accuracy could be improved by anterolateral compensation during target planning. Surgical technique was revised to minimize technical error factors. During 22 implantations, targets were selected on axial magnetic resonance imaging scans up to 1.5 mm anterolateral from the STN center. Using fusion of postoperative computed tomographic and preoperative magnetic resonance imaging scans, implantation errors in the axial plane were obtained and compared with distances from the lead to the STN to evaluate the benefit of anterolateral compensation. Twenty errors and the mean error had a posteromedial direction. The average distances from the lead to the target and to the STN were 1.7 mm (range, 0.8–3.1 mm) and 1.1 mm (range, 0.1–1.9 mm), respectively. The difference between the 2 distances was significant (paired t test, P < 0.0001). The lower parts of the lead were consistently bent in the posteromedial direction on postoperative scout computed tomographic scans, suggesting that a brain-related factor is responsible for the reported error. Elimination of the technical factors of error during STN deep brain stimulation implantation can result in a consistent posteromedial error. Implantation accuracy may be improved by compensation for this error in advance.Keywords
This publication has 31 references indexed in Scilit:
- Brain Shift during Deep Brain Stimulation Surgery for Parkinson’s DiseaseStereotactic and Functional Neurosurgery, 2007
- Variability of the subthalamic nucleus: The case for direct MRI guided targetingBritish Journal Of Neurosurgery, 2007
- Statistical determination of the optimal subthalamic nucleus stimulation site in patients with Parkinson diseaseJournal of Neurosurgery, 2007
- Targeting the subthalamic nucleus for deep brain stimulation: technical approach and fusion of pre- and postoperative MR images to define accuracy of lead placementJournal of Neurology, Neurosurgery & Psychiatry, 2005
- A Simple Method to Assess Accuracy of Deep Brain Stimulation Electrode Placement: Pre-Operative Stereotactic CT + Postoperative MR Image FusionStereotactic and Functional Neurosurgery, 2004
- Effects of Subthalamic Nucleus Stimulation on Urodynamic Findings in Patients with Parkinson’s DiseaseJournal of Urology, 2003
- Lack of agreement between direct magnetic resonance imaging and statistical determination of a subthalamic target: the role of electrophysiological guidanceJournal of Neurosurgery, 2002
- Safety and Risk of Microelectrode Recording in Surgery for Movement DisordersStereotactic and Functional Neurosurgery, 2002
- Deep-Brain Stimulation of the Subthalamic Nucleus or the Pars Interna of the Globus Pallidus in Parkinson's DiseaseNew England Journal of Medicine, 2001
- Bilateral subthalamic stimulation for Parkinson's disease by using three-dimensional stereotactic magnetic resonance imaging and electrophysiological guidanceJournal of Neurosurgery, 2000