Keith G. Davies
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Keith G. Davies has a total of 104 co-authors. Here are the top co-authors by number of shared publications:
Bruce P. Hermann
Department of Neurology, University of Wisconsin, Wisconsin, USA, US
9 shared publicationsAllen R. Wyler
Epilepsy Center, Swedish Medical Center, Seattle, Washington, U.S.A.
4 shared publicationsBrian D. Bell
4 shared publicationsBruce Hermann
4 shared publicationsBruce P Hermann
Department of Neurology, University of Wisconsin, Madison, Wisconsin
4 shared publicationsMichael Seidenberg
Finch University of Health Sciences/Chicago Medical School, North Chicago, Illinois, 60064
4 shared publications
Latest Publications
- 1 October 2013
- Published by Elsevier in Clinical Neurology and Neurosurgery
- Vol. 115 (10) , 2247-2250
Intractable hiccups resolved after resection of a cavernous malformation of the medulla oblongata
- 1 October 2013
- Published by Elsevier in Clinical Neurology and Neurosurgery
- Vol. 115 (10) , 2247-2250
Intractable hiccups resolved after resection of a cavernous malformation of the medulla oblongata
- 6 October 2009
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 152 (2) , 201-210
Assessment of the variability in the anatomical position and size of the subthalamic nucleus among patients with advanced Parkinson’s disease using magnetic resonance imaging
Targeting of the subthalamic nucleus (STN) during deep brain stimulation (DBS) surgery using standard atlas coordinates is used in some centers. Such coordinates are accurate for only a subgroup of patients, and subgroup size depends on the extent of inter-individual variation in STN position/size and degree to which atlas represents average anatomical relations. Few studies have addressed this issue. Sixty-two axial T2-weighted magnetic resonance (MR) images of the brain (1.5 T) were obtained before STN-DBS in 62 patients (37 males) with Parkinson’s disease using a protocol optimized for STN visualization. Image distortion was within sub-millimeter range. Midcommissural point (MCP)-derived coordinates of STN borders, STN center, and other brain landmarks were obtained using stereotactic software. MR-derived measurements were compared to Schaltenbrand and Wahren Atlas. We evaluated 117 best-visualized STNs. STN dimensions and coordinates of its center were highly variable. STN lateral coordinate ranged 8.7 mm–14.5 mm from MCP, A-P coordinate 3.5 mm posterior to 0.5 mm anterior to MCP, and vertical coordinate 1.3 mm–6 mm below MCP. The antero-posterior nucleus dimension varied by 8 mm and lateral-medial dimension by 5.8 mm. Differences between mean values of MR-derived data sets and Atlas values were statistically significant but moderate, excluding AC-PC length, for which the Atlas value was below the 1st percentile of the MR data set. The STN lateral coordinate strongly correlated with the width of the third ventricle (r = 0.73, p < 0.001). It is now possible to directly evaluate STNs at 1.5 T with minimal image distortion, which reveals variation in STN position and dimensions in the range of nucleus size. This puts under question the rationale of use of standard STN coordinates during DBS surgery.
- 6 October 2009
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 152 (2) , 201-210
Assessment of the variability in the anatomical position and size of the subthalamic nucleus among patients with advanced Parkinson’s disease using magnetic resonance imaging
Targeting of the subthalamic nucleus (STN) during deep brain stimulation (DBS) surgery using standard atlas coordinates is used in some centers. Such coordinates are accurate for only a subgroup of patients, and subgroup size depends on the extent of inter-individual variation in STN position/size and degree to which atlas represents average anatomical relations. Few studies have addressed this issue. Sixty-two axial T2-weighted magnetic resonance (MR) images of the brain (1.5 T) were obtained before STN-DBS in 62 patients (37 males) with Parkinson’s disease using a protocol optimized for STN visualization. Image distortion was within sub-millimeter range. Midcommissural point (MCP)-derived coordinates of STN borders, STN center, and other brain landmarks were obtained using stereotactic software. MR-derived measurements were compared to Schaltenbrand and Wahren Atlas. We evaluated 117 best-visualized STNs. STN dimensions and coordinates of its center were highly variable. STN lateral coordinate ranged 8.7 mm–14.5 mm from MCP, A-P coordinate 3.5 mm posterior to 0.5 mm anterior to MCP, and vertical coordinate 1.3 mm–6 mm below MCP. The antero-posterior nucleus dimension varied by 8 mm and lateral-medial dimension by 5.8 mm. Differences between mean values of MR-derived data sets and Atlas values were statistically significant but moderate, excluding AC-PC length, for which the Atlas value was below the 1st percentile of the MR data set. The STN lateral coordinate strongly correlated with the width of the third ventricle (r = 0.73, p < 0.001). It is now possible to directly evaluate STNs at 1.5 T with minimal image distortion, which reveals variation in STN position and dimensions in the range of nucleus size. This puts under question the rationale of use of standard STN coordinates during DBS surgery.
- 1 May 2009
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 64 (5) , ons374-ons384
ISOLATION OF THE BRAIN-RELATED FACTOR OF THE ERROR BETWEEN INTENDED AND ACHIEVED POSITION OF DEEP BRAIN STIMULATION ELECTRODES IMPLANTED INTO THE SUBTHALAMIC NUCLEUS FOR THE TREATMENT OF PARKINSON'S DISEASE
Although a few studies have quantified errors in the implantation of deep brain stimulation electrodes into the subthalamic nucleus (STN), a significant trend in error direction has not been reported. We have previously found that an error in axial plane, which is of most concern because it cannot be compensated for during deep brain stimulation programming, had a posteromedial trend. We hypothesized that this trend results from a predominance of a directionally oriented error factor of brain origin. Accordingly, elimination of nonbrain (technical) error factors could augment this trend. Thus, implantation accuracy could be improved by anterolateral compensation during target planning. Surgical technique was revised to minimize technical error factors. During 22 implantations, targets were selected on axial magnetic resonance imaging scans up to 1.5 mm anterolateral from the STN center. Using fusion of postoperative computed tomographic and preoperative magnetic resonance imaging scans, implantation errors in the axial plane were obtained and compared with distances from the lead to the STN to evaluate the benefit of anterolateral compensation. Twenty errors and the mean error had a posteromedial direction. The average distances from the lead to the target and to the STN were 1.7 mm (range, 0.8–3.1 mm) and 1.1 mm (range, 0.1–1.9 mm), respectively. The difference between the 2 distances was significant (paired t test, P < 0.0001). The lower parts of the lead were consistently bent in the posteromedial direction on postoperative scout computed tomographic scans, suggesting that a brain-related factor is responsible for the reported error. Elimination of the technical factors of error during STN deep brain stimulation implantation can result in a consistent posteromedial error. Implantation accuracy may be improved by compensation for this error in advance.
- 1 May 2009
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 64 (5) , ons374-ons384
ISOLATION OF THE BRAIN-RELATED FACTOR OF THE ERROR BETWEEN INTENDED AND ACHIEVED POSITION OF DEEP BRAIN STIMULATION ELECTRODES IMPLANTED INTO THE SUBTHALAMIC NUCLEUS FOR THE TREATMENT OF PARKINSON'S DISEASE
Although a few studies have quantified errors in the implantation of deep brain stimulation electrodes into the subthalamic nucleus (STN), a significant trend in error direction has not been reported. We have previously found that an error in axial plane, which is of most concern because it cannot be compensated for during deep brain stimulation programming, had a posteromedial trend. We hypothesized that this trend results from a predominance of a directionally oriented error factor of brain origin. Accordingly, elimination of nonbrain (technical) error factors could augment this trend. Thus, implantation accuracy could be improved by anterolateral compensation during target planning. Surgical technique was revised to minimize technical error factors. During 22 implantations, targets were selected on axial magnetic resonance imaging scans up to 1.5 mm anterolateral from the STN center. Using fusion of postoperative computed tomographic and preoperative magnetic resonance imaging scans, implantation errors in the axial plane were obtained and compared with distances from the lead to the STN to evaluate the benefit of anterolateral compensation. Twenty errors and the mean error had a posteromedial direction. The average distances from the lead to the target and to the STN were 1.7 mm (range, 0.8–3.1 mm) and 1.1 mm (range, 0.1–1.9 mm), respectively. The difference between the 2 distances was significant (paired t test, P < 0.0001). The lower parts of the lead were consistently bent in the posteromedial direction on postoperative scout computed tomographic scans, suggesting that a brain-related factor is responsible for the reported error. Elimination of the technical factors of error during STN deep brain stimulation implantation can result in a consistent posteromedial error. Implantation accuracy may be improved by compensation for this error in advance.
- 1 April 2009
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 110 (4) , 754-757
Long thoracic neuropathy caused by an apical pulmonary tumor
Long thoracic nerve palsy has been reported to have traumatic, iatrogenic, and idiopathic causes. The authors describe the case of a 62-year-old man who presented with progressively worsening right shoulder pain, winging of the scapula, and Horner syndrome. A chest CT scan revealed an apical pulmonary mass. To the authors' knowledge, this is the first report of a long thoracic nerve palsy caused by an apical pulmonary tumor.
- 1 April 2009
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 110 (4) , 754-757
Long thoracic neuropathy caused by an apical pulmonary tumor
Long thoracic nerve palsy has been reported to have traumatic, iatrogenic, and idiopathic causes. The authors describe the case of a 62-year-old man who presented with progressively worsening right shoulder pain, winging of the scapula, and Horner syndrome. A chest CT scan revealed an apical pulmonary mass. To the authors' knowledge, this is the first report of a long thoracic nerve palsy caused by an apical pulmonary tumor.
- 31 July 2008
- Published by Elsevier in Epilepsy & Behavior
- Vol. 13 (1) , 3-4
When should mesial temporal structures be preserved?
- 31 July 2008
- Published by Elsevier in Epilepsy & Behavior
- Vol. 13 (1) , 3-4
When should mesial temporal structures be preserved?
- 1 February 2008
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 108 (2) , 425-428
Optimal Stimulation Site
- 1 February 2008
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 108 (2) , 425-428
Optimal Stimulation Site
- 1 January 2008
- Published by S. Karger AG in Stereotactic and Functional Neurosurgery
- Vol. 86 (5) , 330-331
Stereotactic Targeting of the Subthalamic Nucleus: Relevance of Magnetic Resonance-Based Evaluation of Interindividual Variation in Diencephalic Anatomy
- 1 January 2008
- Published by S. Karger AG in Stereotactic and Functional Neurosurgery
- Vol. 86 (5) , 330-331
Stereotactic Targeting of the Subthalamic Nucleus: Relevance of Magnetic Resonance-Based Evaluation of Interindividual Variation in Diencephalic Anatomy
- 1 January 2008
- Published by S. Karger AG in Stereotactic and Functional Neurosurgery
- Vol. 86 (4) , 266-267
Importance of Individual Variation of Anterior Commissure-Posterior Commissure-Derived Subthalamic Nucleus Coordinates in Deep Brain Stimulation Targeting
- 1 January 2008
- Published by S. Karger AG in Stereotactic and Functional Neurosurgery
- Vol. 86 (4) , 266-267
Importance of Individual Variation of Anterior Commissure-Posterior Commissure-Derived Subthalamic Nucleus Coordinates in Deep Brain Stimulation Targeting
- 1 September 2005
- Published by Elsevier in Epilepsy & Behavior
- Vol. 7 (2) , 273-278
Naming ability after tailored left temporal resection with extraoperative language mapping: Increased risk of decline with later epilepsy onset age
- 1 September 2005
- Published by Elsevier in Epilepsy & Behavior
- Vol. 7 (2) , 273-278
Naming ability after tailored left temporal resection with extraoperative language mapping: Increased risk of decline with later epilepsy onset age
- 1 December 2004
- Published by Elsevier in Epilepsy & Behavior
- Vol. 5 (6) , 826-840
The interictal dysphoric disorder: recognition, pathogenesis, and treatment of the major psychiatric disorder of epilepsy
- 1 December 2004
- Published by Elsevier in Epilepsy & Behavior
- Vol. 5 (6) , 826-840
The interictal dysphoric disorder: recognition, pathogenesis, and treatment of the major psychiatric disorder of epilepsy