Active and passive self-ligation—a myth?
Authors:
- Lorenz M. BrauchliLBLorenz M. Brauchli
- Christiane SennCSChristiane Senn
- Andrea WichelhausAWAndrea Wichelhaus
- 1 March 2011
- journal article
- research article
- Published by The Angle Orthodontist (EH Angle Education & Research Foundation) in The Angle Orthodontist
- Vol. 81 (2) , 312-318
Abstract
Objective: To compare the frictional behavior of several self-ligating brackets with that of normal brackets both with and without tipping force-moments and in combination with different archwire dimensions. Materials and Methods: The resistance to sliding (RS) of seven self-ligating brackets, a conventional bracket, and a ceramic bracket with a low-friction clip were evaluated in combination with three different archwires and tipping force-moments of 0 and 10 Nmm. The center of rotation for the measurements was set within the center of the bracket or with a 10-mm offset. Resistance to sliding was measured using an Instron 3344 at a cross-head speed of 10 mm/min at a temperature of 36°C. Results: Without a tipping moment, RS increased with the active self-ligating brackets with increasing archwire size. No RS was found for any of the passive self-ligating brackets. The 10-Nmm tipping moment resulted in more RS and was similar for all bracket and archwire combinations. RS was approximately doubled when the center of rotation was located at the bracket rather than with a 10-mm offset. Conclusions: RS between brackets and archwires is highly dependent on the experimental setup. Different setups can result in contradictory results. Almost 1 N of traction force is lost in RS when a moment of 10 Nmm is placed at a rotational center 10 mm from the bracket.Keywords
This publication has 22 references indexed in Scilit:
- Frictional Resistance in Self-Ligating Orthodontic Brackets and Conventionally Ligated BracketsThe Angle Orthodontist, 2009
- Friction between Archwires of Different Sizes, Cross-Section and Alloy and Brackets Ligated with Low-Friction or Conventional LigaturesThe Angle Orthodontist, 2009
- In Vitro Frictional Forces Generated by Three Different Ligation MethodsThe Angle Orthodontist, 2008
- The effect of different combinations of tip and torque on archwire/bracket frictionEuropean Journal of Orthodontics, 2008
- Self-ligating vs conventional twin brackets during en-masse space closure with sliding mechanicsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2007
- Effect of archwire size and material on the resistance to sliding of self-ligating brackets with second-order angulation in the dry stateAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2002
- Comparison of resistance to sliding between different self-ligating brackets with second-order angulation in the dry and saliva statesAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2002
- Resistance to sliding of self-ligating brackets versus conventional stainless steel twin brackets with second-order angulation in the dry and wet (saliva) statesAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2001
- Influence of angulation on the resistance to sliding in fixed appliancesAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1999
- Friction between different wire-bracketconfigurations and materialsSeminars in Orthodontics, 1997