Evaluation of the potential for diacetylenes as reporter molecules in 3D micelle gel dosimetry
Authors:
- 16 January 2013
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (4) , 787-805
Abstract
Radiochromic micelle gel dosimeters are promising for three-dimensional (3D) radiation dosimetry because they can be read out by optical CT techniques and they have superior spatial stability compared to polymer and Fricke gel dosimeters. This study evaluates the use of diacetylenes as reporter molecules in micelle gel dosimeters. Several gels containing pentacosa-10,12-diynoic acid (PCDA) emulsified using sodium dodecyl sulfate (SDS) changed from colourless to blue upon irradiation. Unfortunately, all phantoms that experienced a colour change were turbid and would be unsuitable for 3D dosimetry. Two techniques (use of organic solvent and aqueous-phase additives) were successful in increasing colloidal stability to prevent the turbidity problem, but none of the resulting transparent gels changed colour in response to radiation. Transparent PCDA emulsions were prepared using NaOH solutions with no SDS or other emulsifier, but these transparent emulsions also did not change colour. Only turbid gels and emulsions with precipitated particles responded to radiation. These results indicate that the colour change was due to the oligomerization within precipitated PCDA crystals, and that liquid-phase emulsified PCDA did not undergo oligomerization. As a result, PCDA is not suitable for use in micelle gel dosimeters, and other radiochromic reporter molecules will need to be identified.Keywords
This publication has 47 references indexed in Scilit:
- Mathematical Modeling of Depth‐Dose Response of Polymer‐Gel DosimetersMacromolecular Theory and Simulations, 2011
- Deposition and Photopolymerization of Phase-Separated Perfluorotetradecanoic Acid–10,12-Pentacosadiynoic Acid Langmuir–Blodgett Monolayer FilmsLangmuir, 2011
- Cosolvent-free polymer gel dosimeters with improved dose sensitivity and resolution for x-ray CT dose responsePhysics in Medicine & Biology, 2011
- Polymer gel dosimetryPhysics in Medicine & Biology, 2010
- Radiochromic leuco dye micelle hydrogels: II. Low diffusion rate leuco crystal violet gelPhysics in Medicine & Biology, 2009
- Radiological properties of the PRESAGE and PAGAT polymer dosimetersApplied Radiation and Isotopes, 2008
- Synthesis of Poly(ethylene glycol)-Polydiacetylene Conjugates and Their Micellar and Chromic CharacteristicsJournal of Nanoscience and Nanotechnology, 2008
- Characterisation of PRESAGE™: A new 3-D radiochromic solid polymer dosemeter for ionising radiationRadiation Protection Dosimetry, 2006
- Modern Aspects of Emulsion Science1998
- Imaging of spatial radiation dose distribution in agarose gels using magnetic resonanceMedical Physics, 1987