Selective Electrochemical Sensing of Riboflavin Based on Functionalized Multi-Walled Carbon Nanotube/Gold Nanoparticle/Pencil Graphite Electrode
- 25 November 2020
- journal article
- research article
- Published by The Electrochemical Society in ECS Journal of Solid State Science and Technology
- Vol. 9 (12) , 121003
Abstract
In this study; an easy, practical, and selective sensor has been developed for the electrochemical determination of riboflavin. To prepare the modified electrode, the gold nanoparticle was deposited on the pencil graphite electrode (AuNP/PGE) by the method of chronoamperometry at −3.0 V for 30 s in 0.5 M H 2 SO 4 solution containing 10 mM tetrachloroaurate. Functionalized multi-walled carbon nanotube (f-MWCNT) solution was dropped on prepared AuNP/PGE and the functionalized multi-walled carbon nanotube/gold nanoparticle/pencil graphite electrode (f-MWCNT/AuNP/PGE) was prepared for measurements. Characterization studies of the prepared sensor were performed using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), energy-dispersive X-ray spectroscopy (EDX), and X-ray photoelectron spectroscopy (XPS) methods. The surface morphology of the prepared sensor was investigated by field emission scanning electron microscopy (FESEM). Differential pulse voltammetry (DPV) was used to carry out electrochemical measurements in phosphate buffer solution pH 4.0. Limit of detection (LOD) and limit of quantitation (LOQ) values were found to be 0.0352 and 0.118 μ mol l −1 , respectively. The fabricated sensor showed excellent anti-interference ability against ascorbic acid (AA) and glucose (G). The applicability of the constructed sensor to real samples was investigated and good recovery values were achieved. As a result, it has been seen that the modified electrode is applicable in applications of riboflavin determination.Keywords
This publication has 53 references indexed in Scilit:
- Fabrication of Cr doped SnO2 nanoparticles based biosensor for the selective determination of riboflavin in pharmaceuticalsThe Analyst, 2013
- Voltammetric monitoring of electrochemical reduction of riboflavin using silver solid amalgam electrodesElectrochimica Acta, 2012
- Sensitive electrochemical determination of acetaminophen in pharmaceutical formulations at multiwalled carbon nanotube-alumina-coated silica nanocomposite modified electrodeSensors and Actuators B: Chemical, 2011
- Preparation of selective and sensitive electrochemically treated pencil graphite electrodes for the determination of uric acid in urine and blood serumBiosensors and Bioelectronics, 2010
- Biological applications of diamond electrodes; electrochemical studies of riboflavinDiamond and Related Materials, 2009
- Determination of riboflavin by enhancing the chemiluminescence intensity of peroxomonosulfate–cobalt(II) systemSpectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2007
- Simultaneous Spectrophotometric Multicomponent Determination of Folic Acid, Thiamine, Riboflavin, and Pyridoxal by Using Double Divisor–Ratio Spectra Derivative–Zero Crossing MethodAnalytical Letters, 2004
- Simultaneous Voltammetric Determination of Riboflavin andl-Ascorbic Acid in Multivitamin Pharmaceutical PreparationsJournal of Trace and Microprobe Techniques, 2003
- Application of differential pulse polarography to the assay of ascorbic acidMicrochemical Journal, 1983
- HPLC Determination of Riboflavin in Eggs and Dairy ProductsJournal of Food Science, 1983