Ebrar Dokur
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ebrar Dokur has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Yucel Sahin
Yildiz Technical University
10 shared publications - Ozge Gorduk
Yildiz Technical University
9 shared publications - Selen Uruc
Yildiz Technical University
7 shared publications - Rabianur Kurteli
Department of Chemistry, Faculty of Arts and Science, Yildiz Technical University, TR34220 Istanbul, Türkiye
3 shared publications Ozge Gorduk
2 shared publications- Merve Yalcin Acikalin
Department of Chemistry, Faculty of Arts and Science, Yildiz Technical University, Istanbul, Turkey
1 shared publication
Latest Publications
- 13 May 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (10)
β-Cyclodextrin Modified Paper-Based Electrodes Fabricated with Ti3C2Tx MXene/NiO Conductive Ink for Selective Non-Enzymatic Phenylalanine Detection
Phenylalanine (Phe), an essential amino acid, plays a critical role in key biological processes, including protein biosynthesis and neurotransmitter production. It also serves as a biomarker in the diagnosis of diseases that may result in severe neurological damage, such as phenylketonuria. Therefore, the development of selective and sensitive sensing platforms for Phe detection is of great importance. In this study, a novel non-enzymatic electrochemical detection platform was developed based on a Ti3C2Tx MXene/NiO conductive ink integrated onto paper-based screen-printed electrodes (SPEs). The high surface area and adsorption capability of the MXene/NiO composite enabled the effective immobilization of β-cyclodextrin (β-CD) onto the electrode surface, promoting selective Phe recognition via host-guest interactions. Under optimized conditions, the sensor exhibited a wide linear range from 0.05 to 1000 µM and a low detection limit of 0.0157 µM for Phe determination. The platform also showed good selectivity against common interfering species. In artificial sample analysis, recovery% values ranged from 97.0% to 114.0%, with RSD% values between 2.68% and 3.50%, indicating acceptable accuracy and precision. Morphological, structural, and electrochemical characterizations were performed. These results demonstrate that the proposed platform offers a promising, low-cost, and versatile strategy for the development of flexible and wearable electrochemical sensors.
- 13 May 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (10)
β-Cyclodextrin Modified Paper-Based Electrodes Fabricated with Ti3C2Tx MXene/NiO Conductive Ink for Selective Non-Enzymatic Phenylalanine Detection
Phenylalanine (Phe), an essential amino acid, plays a critical role in key biological processes, including protein biosynthesis and neurotransmitter production. It also serves as a biomarker in the diagnosis of diseases that may result in severe neurological damage, such as phenylketonuria. Therefore, the development of selective and sensitive sensing platforms for Phe detection is of great importance. In this study, a novel non-enzymatic electrochemical detection platform was developed based on a Ti3C2Tx MXene/NiO conductive ink integrated onto paper-based screen-printed electrodes (SPEs). The high surface area and adsorption capability of the MXene/NiO composite enabled the effective immobilization of β-cyclodextrin (β-CD) onto the electrode surface, promoting selective Phe recognition via host-guest interactions. Under optimized conditions, the sensor exhibited a wide linear range from 0.05 to 1000 µM and a low detection limit of 0.0157 µM for Phe determination. The platform also showed good selectivity against common interfering species. In artificial sample analysis, recovery% values ranged from 97.0% to 114.0%, with RSD% values between 2.68% and 3.50%, indicating acceptable accuracy and precision. Morphological, structural, and electrochemical characterizations were performed. These results demonstrate that the proposed platform offers a promising, low-cost, and versatile strategy for the development of flexible and wearable electrochemical sensors.
- 2 June 2025
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 49 (26) , 11344-11360
A novel approach for non-enzymatic determination of urea via a screen-printed electrode prepared with a conductive ink containing graphene and nickel oxide
This study presents a novel low-cost, screen-printed flexible sensor platform made of a graphene-based conductive ink with a metallic material.
- 2 June 2025
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 49 (26) , 11344-11360
A novel approach for non-enzymatic determination of urea via a screen-printed electrode prepared with a conductive ink containing graphene and nickel oxide
This study presents a novel low-cost, screen-printed flexible sensor platform made of a graphene-based conductive ink with a metallic material.
- 20 May 2024
- Published by Springer Nature in Ionics
- Vol. 30 (7) , 4203-4214
Silver nanoparticle–incorporated over-oxidized poly(3,4-ethylenedioxythiophene)-based electrochemical sensor for selective determination of riboflavin
- 20 May 2024
- Published by Springer Nature in Ionics
- Vol. 30 (7) , 4203-4214
Silver nanoparticle–incorporated over-oxidized poly(3,4-ethylenedioxythiophene)-based electrochemical sensor for selective determination of riboflavin
- 26 February 2024
- Published by Taylor & Francis in Analytical Letters
- Vol. 58 (12) , 1931-1951
Selective Amperometric Sensor for the Determination of Hydrazine at a Gold Nanoparticle Decorated Poly(Brilliant Blue) Modified Electrode
- 26 February 2024
- Published by Taylor & Francis in Analytical Letters
- Vol. 58 (12) , 1931-1951
Selective Amperometric Sensor for the Determination of Hydrazine at a Gold Nanoparticle Decorated Poly(Brilliant Blue) Modified Electrode
- 6 October 2023
- Published by Springer Nature in Ionics
- Vol. 29 (12) , 5465-5480
Designing disposable hand-made screen-printed electrode using conductive ink for electrochemical determination of dopamine
- 6 October 2023
- Published by Springer Nature in Ionics
- Vol. 29 (12) , 5465-5480
Designing disposable hand-made screen-printed electrode using conductive ink for electrochemical determination of dopamine
- 13 March 2023
- Published by Springer Nature in Ionics
- Vol. 29 (5) , 2005-2019
A novel approach for ultrasensitive amperometric determination of NADH via graphene-based electrode obtained by electrochemical intercalation of tetraalkylammonium ions
- 13 March 2023
- Published by Springer Nature in Ionics
- Vol. 29 (5) , 2005-2019
A novel approach for ultrasensitive amperometric determination of NADH via graphene-based electrode obtained by electrochemical intercalation of tetraalkylammonium ions
- 14 July 2022
- Published by Wiley in ChemElectroChem
- Vol. 9 (15)
Ultrasensitive Electrochemical Detection of Carcinoembryonic Antigen with a Label‐Free Immunosensor Using Gold Nanoparticle‐Decorated Poly(pyrrole‐co‐3,4‐ethylenedioxythiophene)
In this study, an electrochemical immunosensor was developed using gold nanoparticles (AuNPs), 3,4‐ethylenedioxythiophene (EDOT), and pyrrole (Py) to detect carcinoembryonic antigen (CEA) sensitively. Firstly, the electrocopolymerization of PPy and EDOT was carried out on a pencil graphite electrode (PGE) by the chronoamperometry method (p(Py‐co‐EDOT)/PGE). Then, gold nanoparticles were electrochemically deposited on the prepared p(Py‐co‐EDOT)/PGEs by the chronoamperometry method. The characterizations of the developed label‐free immunosensor (AuNPs/p(Py‐co‐EDOT)/PGE) were carried out using CV, EIS, XPS, SEM, EDX, and FTIR methods. Antibody concentration, antibody immobilization time, and immunocomplex time were optimized using differential pulse voltammetry (DPV). After optimal conditions are determined, the DPV peak current of the immunosensor decreases linearly with increasing CEA concentration of 0.001–100 ng mL−1. The detection limit was calculated as 0.741 pg mL−1 from the calibration graph (S/N=3). The developed sensor showed excellent anti‐interference ability against ascorbic acid, bovine serum albumin, dopamine, and glucose. The applicability of the developed sensor to real samples was investigated, and good recovery values were obtained. As a result, the AuNPs/p(Py‐EDOT)/PGE provides low‐cost, selective, and rapid detection of CEA. Our findings suggest the present immunosensor is a good candidate for application in clinical screening.
- 14 July 2022
- Published by Wiley in ChemElectroChem
- Vol. 9 (15)
Ultrasensitive Electrochemical Detection of Carcinoembryonic Antigen with a Label‐Free Immunosensor Using Gold Nanoparticle‐Decorated Poly(pyrrole‐co‐3,4‐ethylenedioxythiophene)
In this study, an electrochemical immunosensor was developed using gold nanoparticles (AuNPs), 3,4‐ethylenedioxythiophene (EDOT), and pyrrole (Py) to detect carcinoembryonic antigen (CEA) sensitively. Firstly, the electrocopolymerization of PPy and EDOT was carried out on a pencil graphite electrode (PGE) by the chronoamperometry method (p(Py‐co‐EDOT)/PGE). Then, gold nanoparticles were electrochemically deposited on the prepared p(Py‐co‐EDOT)/PGEs by the chronoamperometry method. The characterizations of the developed label‐free immunosensor (AuNPs/p(Py‐co‐EDOT)/PGE) were carried out using CV, EIS, XPS, SEM, EDX, and FTIR methods. Antibody concentration, antibody immobilization time, and immunocomplex time were optimized using differential pulse voltammetry (DPV). After optimal conditions are determined, the DPV peak current of the immunosensor decreases linearly with increasing CEA concentration of 0.001–100 ng mL−1. The detection limit was calculated as 0.741 pg mL−1 from the calibration graph (S/N=3). The developed sensor showed excellent anti‐interference ability against ascorbic acid, bovine serum albumin, dopamine, and glucose. The applicability of the developed sensor to real samples was investigated, and good recovery values were obtained. As a result, the AuNPs/p(Py‐EDOT)/PGE provides low‐cost, selective, and rapid detection of CEA. Our findings suggest the present immunosensor is a good candidate for application in clinical screening.
- 24 March 2021
- Published by Wiley in Electroanalysis
- Vol. 33 (6) , 1657-1667
Cost‐effective and Facile Production of a Phosphorus‐doped Graphite Electrode for the Electrochemical Determination of Pyridoxine
In this study; a sensitive, selective, and simple electrochemical sensor was developed to determine low concentration pyridoxine (Py) using a phosphorus‐doped pencil graphite electrode (P‐doped/PGE). Electrode modification was implemented using the chronoamperometry method at +2.0 V constant potential and 100 seconds in 0.1 mol L−1 H3PO4 supporting electrolyte solution. The characterization processes of the P‐doped/PGE were carried out using electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), X‐ray photoelectron spectroscopy (XPS), field emission scanning electron microscopy (FESEM), energy‐dispersive X‐ray spectroscopy (EDX), and atomic force microscope (AFM) methods. In the concentration study, using the differential pulse voltammetry (DPV) method, a linear calibration plot was acquired in the concentration range of 0.5 to 300 μmol L−1 Py. The limit of quantification (LOQ) and limit of detection (LOD) of the developed method were calculated as 0.219 μmol L−1 and 0.0656 μmol L−1, respectively. Detection of Py has been successfully performed on the P‐doped/PGE in the beverage samples. As a result, the method developed has been shown to have fast, low cost, and simple for the sensitive and selective detection of Py as an effective electrode.
- 24 March 2021
- Published by Wiley in Electroanalysis
- Vol. 33 (6) , 1657-1667
Cost‐effective and Facile Production of a Phosphorus‐doped Graphite Electrode for the Electrochemical Determination of Pyridoxine
In this study; a sensitive, selective, and simple electrochemical sensor was developed to determine low concentration pyridoxine (Py) using a phosphorus‐doped pencil graphite electrode (P‐doped/PGE). Electrode modification was implemented using the chronoamperometry method at +2.0 V constant potential and 100 seconds in 0.1 mol L−1 H3PO4 supporting electrolyte solution. The characterization processes of the P‐doped/PGE were carried out using electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), X‐ray photoelectron spectroscopy (XPS), field emission scanning electron microscopy (FESEM), energy‐dispersive X‐ray spectroscopy (EDX), and atomic force microscope (AFM) methods. In the concentration study, using the differential pulse voltammetry (DPV) method, a linear calibration plot was acquired in the concentration range of 0.5 to 300 μmol L−1 Py. The limit of quantification (LOQ) and limit of detection (LOD) of the developed method were calculated as 0.219 μmol L−1 and 0.0656 μmol L−1, respectively. Detection of Py has been successfully performed on the P‐doped/PGE in the beverage samples. As a result, the method developed has been shown to have fast, low cost, and simple for the sensitive and selective detection of Py as an effective electrode.
- 25 November 2020
- Published by The Electrochemical Society in ECS Journal of Solid State Science and Technology
- Vol. 9 (12) , 121003
Selective Electrochemical Sensing of Riboflavin Based on Functionalized Multi-Walled Carbon Nanotube/Gold Nanoparticle/Pencil Graphite Electrode
In this study; an easy, practical, and selective sensor has been developed for the electrochemical determination of riboflavin. To prepare the modified electrode, the gold nanoparticle was deposited on the pencil graphite electrode (AuNP/PGE) by the method of chronoamperometry at −3.0 V for 30 s in 0.5 M H 2 SO 4 solution containing 10 mM tetrachloroaurate. Functionalized multi-walled carbon nanotube (f-MWCNT) solution was dropped on prepared AuNP/PGE and the functionalized multi-walled carbon nanotube/gold nanoparticle/pencil graphite electrode (f-MWCNT/AuNP/PGE) was prepared for measurements. Characterization studies of the prepared sensor were performed using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), energy-dispersive X-ray spectroscopy (EDX), and X-ray photoelectron spectroscopy (XPS) methods. The surface morphology of the prepared sensor was investigated by field emission scanning electron microscopy (FESEM). Differential pulse voltammetry (DPV) was used to carry out electrochemical measurements in phosphate buffer solution pH 4.0. Limit of detection (LOD) and limit of quantitation (LOQ) values were found to be 0.0352 and 0.118 μ mol l −1 , respectively. The fabricated sensor showed excellent anti-interference ability against ascorbic acid (AA) and glucose (G). The applicability of the constructed sensor to real samples was investigated and good recovery values were achieved. As a result, it has been seen that the modified electrode is applicable in applications of riboflavin determination.
- 25 November 2020
- Published by The Electrochemical Society in ECS Journal of Solid State Science and Technology
- Vol. 9 (12) , 121003
Selective Electrochemical Sensing of Riboflavin Based on Functionalized Multi-Walled Carbon Nanotube/Gold Nanoparticle/Pencil Graphite Electrode
In this study; an easy, practical, and selective sensor has been developed for the electrochemical determination of riboflavin. To prepare the modified electrode, the gold nanoparticle was deposited on the pencil graphite electrode (AuNP/PGE) by the method of chronoamperometry at −3.0 V for 30 s in 0.5 M H 2 SO 4 solution containing 10 mM tetrachloroaurate. Functionalized multi-walled carbon nanotube (f-MWCNT) solution was dropped on prepared AuNP/PGE and the functionalized multi-walled carbon nanotube/gold nanoparticle/pencil graphite electrode (f-MWCNT/AuNP/PGE) was prepared for measurements. Characterization studies of the prepared sensor were performed using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), energy-dispersive X-ray spectroscopy (EDX), and X-ray photoelectron spectroscopy (XPS) methods. The surface morphology of the prepared sensor was investigated by field emission scanning electron microscopy (FESEM). Differential pulse voltammetry (DPV) was used to carry out electrochemical measurements in phosphate buffer solution pH 4.0. Limit of detection (LOD) and limit of quantitation (LOQ) values were found to be 0.0352 and 0.118 μ mol l −1 , respectively. The fabricated sensor showed excellent anti-interference ability against ascorbic acid (AA) and glucose (G). The applicability of the constructed sensor to real samples was investigated and good recovery values were achieved. As a result, it has been seen that the modified electrode is applicable in applications of riboflavin determination.