User Perceptions of Visual Blood: An International Mixed Methods Study on Novel Blood Gas Analysis Visualization
Authors:
- Greta GasciauskaiteGGGreta Gasciauskaite
- Justyna LunkiewiczJLJustyna Lunkiewicz
- Giovanna SchweigerGSGiovanna Schweiger
- Alexandra D. BudowskiABAlexandra D. Budowski
- David HenckertDHDavid Henckert
- Tadzio R. RocheTRTadzio R. Roche
- Lisa BergauerLBLisa Bergauer
- Patrick MeybohmPMPatrick Meybohm
- Sebastian HottenrottSHSebastian Hottenrott
- Kai ZacharowskiKZKai Zacharowski
- Florian Jürgen RaimannFRFlorian Jürgen Raimann
- Eva RivasEREva Rivas
Open Access
- 30 September 2023
- journal article
- research article
- Published by MDPI AG in Diagnostics
- Vol. 13 (19) , 3103
Abstract
Blood gas analysis plays a central role in modern medicine. Advances in technology have expanded the range of available parameters and increased the complexity of their interpretation. By applying user-centered design principles, it is possible to reduce the cognitive load associated with interpreting blood gas analysis. In this international, multicenter study, we explored anesthesiologists’ perspectives on Visual Blood, a novel visualization technique for presenting blood gas analysis results. We conducted interviews with participants following two computer-based simulation studies, the first utilizing virtual reality (VR) (50 participants) and the second without VR (70 participants). Employing the template approach, we identified key themes in the interview responses and formulated six statements, which were rated using Likert scales from 1 (strongly disagree) to 5 (strongly agree) in an online questionnaire. The most frequently mentioned theme was the positive usability features of Visual Blood. The online survey revealed that participants found Visual Blood to be an intuitive method for interpreting blood gas analysis (median 4, interquartile range (IQR) 4-4, p < 0.001). Participants noted that minimal training was required to effectively learn how to interpret Visual Blood (median 4, IQR 4-4, p < 0.001). However, adjustments are necessary to reduce visual overload (median 4, IQR 2-4, p < 0.001). Overall, Visual Blood received a favorable response. The strengths and weaknesses derived from these data will help optimize future versions of Visual Blood to improve the presentation of blood gas analysis results.Keywords
All Related Versions
Funding Information
- Institute of Anesthesiology, University Hospital Zurich
This publication has 31 references indexed in Scilit:
- Global, regional, and national incidence, prevalence, and years lived with disability for 301 acute and chronic diseases and injuries in 188 countries, 1990–2013: a systematic analysis for the Global Burden of Disease Study 2013The Lancet, 2015
- Standards for Reporting Qualitative ResearchAcademic Medicine, 2014
- Information Overload and Missed Test Results in Electronic Health Record–Based SettingsJAMA Internal Medicine, 2013
- Accuracy of interpretation of arterial blood gases by emergency medicine doctorsEmergency Medicine Australasia, 2010
- Novel Representation of Clinical Information in the ICUApplied Clinical Informatics, 2010
- Consolidated criteria for reporting qualitative research (COREQ): a 32-item checklist for interviews and focus groupsInternational Journal for Quality in Health Care, 2007
- The Evaluation of a Pulmonary Display to Detect Adverse Respiratory Events Using High Resolution Human SimulatorJournal of the American Medical Informatics Association, 2006
- Evaluating a Graphical Cardiovascular Display for AnesthesiaProceedings of the Human Factors and Ergonomics Society Annual Meeting, 2001
- The challenge of complexity in health careBMJ, 2001
- Interpretation of blood gas analysis by physicians in a community teaching hospitalRespiratory Medicine, 1979