Bayesian Hierarchical Methods to Interpret the 13C-Octanoic Acid Breath Test for Gastric Emptying
Open Access
- 1 November 2010
- journal article
- research article
- Published by S. Karger AG in Digestion
- Vol. 83 (1-2) , 96-107
Abstract
Background:The 13C-octanoic acid breath test is a convenient method for assessing gastric emptying (GE). Success depends on obtaining a well-characterized time profile of the excretion of label in breath, which may not be the case if GE is delayed. Aims: To use Bayesian techniques in conjunction with hierarchical modelling as a method to increase the success of the modelling process. Methods: Retrospective analysis of 164 individual breath tests using the WinBUGS program. The approach was tested by analysing the complete dataset simultaneously, and also as individual studies. Results: The time required for Bayesian modelling was comparable with that needed for the usual methods. The results obtained were almost identical to those obtained from conventional modelling for well-behaved breath tests, but much more realistic in cases where the experimental data was poor, or when GE was delayed. Conclusions: The use of Bayesian estimation of the parameters of the 13C-octanoic acid breath test is demonstrated. By adopting a hierarchical model, realistic values for the lag phase and half-emptying time were obtained in situations when conventional parameter estimation failed. This is particularly relevant when GE is unexpectedly delayed. We recommend that WinBUGS become the method of choice for analysing breath test data.Keywords
This publication has 18 references indexed in Scilit:
- Frequent feeding delays the gastric emptying of a subsequent mealAppetite, 2007
- Measurement of gastric emptying by the13C-octanoate breath test—rationalization with scintigraphyPhysiological Measurement, 2006
- Measurement of gastric emptying by octanoate metabolismCurrent Opinion in Clinical Nutrition and Metabolic Care, 2005
- A population-based Bayesian approach to the minimal model of glucose and insulin homeostasisStatistics in Medicine, 2005
- Theoretical Flaws in the Gastric Emptying Breath Test: Why is it Dubious?Digestive Diseases and Sciences, 2005
- Modified 13C-Octanoate Breath Test and Impact of Sampling PointsJournal of Clinical Gastroenterology, 2004
- Significance of diagnostic parameters in [13C]octanoic acid gastric emptying breath tests.1998
- A new correction factor for use in tracer estimations of plasma fatty acid oxidationAmerican Journal of Physiology-Endocrinology and Metabolism, 1995
- Intestinal absorption and liver uptake of medium-chain fatty acids in non-anaesthetized pigsBritish Journal of Nutrition, 1993
- Biphasic nature of gastric emptying.Gut, 1988