Method for Measuring Cooling Efficiency of Water Droplets Impinging onto Hot Metal Discs
Open Access
- 9 June 2018
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 8 (6) , 953
Abstract
The present work outlines a method for measuring the cooling efficiency of droplets impinging onto hot metal discs in the temperature range of 85 °C to 400 °C, i.e., covering the boiling regimes experienced when applying water to heated objects in fires. Stainless steel and aluminum test discs (with 50-mm diameter, 10-mm thickness, and a surface roughness of Ra 0.4 or Ra 3) were suspended horizontally by four thermocouples that were used to record disc temperatures. The discs were heated by a laboratory burner prior to the experiments, and left to cool with and without applying 2.4-mm diameter water droplets to the discs while the disc temperatures were recorded. The droplets were generated by the acceleration of gravity from a hypodermic injection needle, and hit the disc center at a speed of 2.2 m/s and a rate of 0.02 g/s, i.e., about three droplets per second. Based on the recorded rate of the temperature change, as well as disc mass and disc heat capacity, the absolute droplet cooling effect and the relative cooling efficiency relative to complete droplet evaporation were obtained. There were significant differences in the cooling efficiency as a function of temperature for the two metals investigated, but there was no statistically significant difference with respect to whether the surface roughness was Ra 0.4 or Ra 3. Aluminum showed a higher cooling efficiency in the temperature range of 110 °C to 140 °C, and a lower cooling efficiency in the temperature range of 180 °C to 300 °C compared to stainless steel. Both metals gave a maximum cooling efficiency in the range of 75% to 85%. A minimum of 5% cooling efficiency was experienced for the aluminum disc at 235 °C, i.e., the observed Leidenfrost point. However, stainless steel did not give a clear minimum in cooling efficiency, which was about 12–14% for disc temperatures above 300 °C. This simple and straightforward technique is well suited for assessing the cooling efficiency of water droplets impinging onto heated metal objects. The test rig also worked well for demonstrating droplet boiling regimes and water droplet cooling efficiency to fire safety engineering students.Keywords
Funding Information
- Norges Forskningsråd (257901)
- Gassco Inc (4500024195)
This publication has 20 references indexed in Scilit:
- High mass flux spray cooling with additives of low specific heat and surface tension: A novel process to enhance the heat removal rateApplied Thermal Engineering, 2017
- The effect of Weber number, droplet sizes and wall roughness on crisis of droplet boilingExperimental Thermal and Fluid Science, 2017
- Water droplets evaporating on horizontal semi-infinite solids at room temperatureApplied Thermal Engineering, 2016
- Behavior of Small Droplet Impinging on a Hot SurfaceHeat Transfer Engineering, 2013
- Influence of the substrate thermal properties on sessile droplet evaporation: Effect of transient heat transportColloids and Surfaces A: Physicochemical and Engineering Aspects, 2013
- Theoretical and experimental analysis of droplet evaporation on solid surfacesChemical Engineering Science, 2012
- Study of fire-extinguishing performance of portable water-mist fire extinguisher in historical buildingsJournal of Cultural Heritage, 2010
- Influence of heating temperature and relative humidity in the evaporation of pinned dropletsColloids and Surfaces A: Physicochemical and Engineering Aspects, 2008
- Droplet Evaporation Study Applied to DNA Chip ManufacturingLangmuir, 2005