Evaluation of performance parameters of indigenously developed roots pumping system
Authors:
Open Access
- 1 August 2016
- conference paper
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 146 (1) , 012047
Abstract
Roots pumping systems are widely used in industries to generate vacuum with high pumping speed. In the present work, the performance parameters of indigenously developed Roots pumping system have been studied. The performance parameters being studied are the ultimate pressure, working temperature, compression ratio and pumping speed. Ultimate pressure of the Roots pump after continuous running of eight hours is found to be 1.1x10-3 mbar. The most important parameter of the roots pump is the zero-gas flow compression Ratio (Ko) which is found to be 18 for the pumping system under study. Efficiency of Roots pump is found to be 76% which is in good agreement as reported in the literature.Keywords
This publication has 1 reference indexed in Scilit: