Influence of Artificial Soft Tissue on Intra-Operative Vibration Analysis Method for Primary Fixation Monitoring in Cementless Total Hip Arthroplasty
Open Access
- 15 April 2022
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 12 (8) , 4027
Abstract
In cementless Total Hip Arthroplasty (THA), achieving high primary implant fixation is crucial for the long-term survivorship of the femoral stem. While orthopedic surgeons traditionally assess fixation based on their subjective judgement, novel vibration-analysis fixation-monitoring techniques show promising potential in providing the surgeon with objective and quantifiable fixation measurements. This study presents a dynamic response measurement protocol for implant endpoint insertion and evaluates this protocol in the presence of artificial soft tissue. After the artificial femur was prepared in accordance with the THA protocol, the implant was inserted and progressively hammered into the cavity. The Pearson Correlation Coefficient (PCC) and Frequency Response Assurance Criterion (FRAC) corresponding to each insertion hammer hit were derived from the Frequency Response Functions (FRF) corresponding to each insertion step. The protocol was repeated with the artificial femur submerged in artificial soft tissue to imitate the influence of anatomical soft tissue. The FRAC appeared overall more sensitive than the PCC. In the presence of the artificial soft tissue the technique yielded higher PCC and FRAC values earlier in the insertion process. The measurements with artificial soft tissue produced FRFs with fewer peaks, lower resonance frequencies, and overall higher damping factors. The soft tissue appears to limit the fixation-change detection capabilities of the system and a promising potential remedy to this limitation is suggested.Keywords
Funding Information
- KU Leuven (Internal Funds)
This publication has 20 references indexed in Scilit:
- Development of an acoustic measurement protocol to monitor acetabular implant fixation in cementless total hip Arthroplasty: A preliminary studyMedical Engineering & Physics, 2017
- Determination of replicate composite bone material properties using modal analysisJournal of the Mechanical Behavior of Biomedical Materials, 2017
- Material model of pelvic bone based on modal analysis: a study on the composite boneBiomechanics and Modeling in Mechanobiology, 2016
- Characterization and evaluation of tissue-mimicking gelatin phantoms for use with MRgFUSJournal of Therapeutic Ultrasound, 2015
- Assessment of implant stability of cementless hip prostheses through the frequency response function of the stem–bone systemSensors and Actuators A: Physical, 2010
- In vivo evaluation of a vibration analysis technique for the per-operative monitoring of the fixation of hip prosthesesJournal of Orthopaedic Surgery and Research, 2009
- Total hip arthroplasties: What are the reasons for revision?International Orthopaedics, 2007
- In vivo and noninvasive six degrees of freedom patellar tracking during voluntary knee movementClinical Biomechanics, 2003
- In vivo assessment of bone mechanical properties by vibration and ultrasonic wave propagation analysisBone, 1996
- The Influence of Joints and Soft Tissue on the Natural Frequency of the Human Tibia Using the Impulse Response MethodProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1995