Thickness distribution and site-specific variability of thermoformed multilayer clear aligners: an in vitro study
Open Access
- 1 June 2026
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Dental Medicine
- Vol. 7, 1863922
Abstract
Introduction: Thermoforming is a critical step in the fabrication of clear aligners and is associated with non-uniform deformation of thermoplastic materials, resulting in non-uniform thickness distribution. Because aligner thickness directly influences stiffness and force delivery, such variability may affect the accuracy and predictability of orthodontic treatment. Aim: This study aimed to evaluate the thickness distribution of thermoformed clear aligners across different tooth regions and anatomical sites, with a focus on identifying patterns of non-uniform material thinning. Methods: Ten thermoformed aligners fabricated from 760 µm multilayer thermoplastic sheets (Zendura FLX) were analyzed in vitro . Thickness measurements were obtained using a calibrated digital caliper at standardized anatomical reference points across anterior, canine, premolar, and molar regions. Generalized estimating equations (GEE) with robust standard errors were used to account for repeated measurements within the same aligner, and pairwise comparisons were adjusted using the Bonferroni correction. Results: Significant differences in thickness were observed among tooth regions ( p < 0.001), with the lowest values in anterior teeth (404.0 ± 5.9 µm) and the highest in molars (481.6 ± 6.0 µm). Thickness reduction ranged from approximately 36% to 47% relative to the original material. Site-specific analysis demonstrated that the facial regions generally exhibited lower thickness values than corresponding palatal regions, indicating non-uniform thermoforming-induced deformation patterns. These findings demonstrated that anatomical location was a major determinant of thickness variability. Conclusion: Thermoformed clear aligners exhibit pronounced and systematic non-uniform thickness distribution strongly influenced by tooth morphology and local geometry characteristics. This non-uniform thickness distribution may contribute to variations in force delivery and should be considered in aligner design and clinical application.Keywords
This publication has 17 references indexed in Scilit:
- Effect of material composition and thickness of orthodontic aligners on the transmission and distribution of forces: an in vitro studyClinical Oral Investigations, 2024
- Overview of systematic reviews and meta-analyses assessing the predictability and clinical effectiveness of clear aligner therapyDentistry Review, 2023
- Comparison of translucency, thickness, and gap width of thermoformed and 3D-printed clear aligners using micro-CT and spectrophotometerScientific Reports, 2023
- Predictability of anterior open bite treatment with InvisalignAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2023
- Are aligners capable of inducing palatal bodily translation or palatal root torque of upper central incisors? A biomechanical in vitro studyClinical Oral Investigations, 2023
- Predictability of orthodontic tooth movement with aligners: effect of treatment designProgress in Orthodontics, 2023
- Three-dimensional analysis of aligner gaps and thickness distributions, using hard x-ray tomography with micrometer resolutionJournal of Medical Imaging, 2022
- Evaluation of open bite closure using clear aligners: a retrospective studyProgress in Orthodontics, 2020
- Thickness of orthodontic clear aligners after thermoforming and after 10 days of intraoral exposure: a prospective clinical studyProgress in Orthodontics, 2019
- A comparison of treatment effectiveness between clear aligner and fixed appliance therapiesBMC Oral Health, 2019