Thị Bích Vân Trần
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Thị Bích Vân Trần has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
An-Tran Pham
Faculty of Dentistry, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam
2 shared publicationsDai-Phong Lam
Faculty of Dentistry, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam
2 shared publicationsHoang-Lan-Anh Le
Faculty of Dentistry, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam
2 shared publicationsHoang-Vinh Le
Faculty of Dentistry, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam
2 shared publicationsHuynh-Anh Bui
Faculty of Dentistry, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam
2 shared publicationsNgoc Anh Thu Pham
Faculty of Dentistry, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam
2 shared publications
Latest Publications
- Open Access
- 18 September 2026
- Published by Frontiers Media SA in Frontiers in Dental Medicine
- Vol. 7, 1889969
Effect of 3D-printed model base height on thickness distribution of thermoformed zendura FLX dual-layer clear aligners: an in vitro study
Background: Thermoforming of clear aligners causes non-uniform material thinning that may influence the structural and mechanical characteristics of the aligners. While greater model base height (MBH) has been shown to increase thinning in single-layer aligners, its effect on dual-layer materials remains unclear. This study aimed to evaluate the effect of four MBH levels (2, 4, 6, and 8 mm) on the thickness distribution of thermoformed Zendura FLX dual-layer clear aligners. Methods: Forty Zendura FLX aligners were thermoformed over standardized 3D-printed maxillary models with MBH of 2, 4, 6, and 8 mm ( n = 10 per group). Thickness was measured at multiple tooth-specific sites across four representative teeth (central incisor, canine, first premolar, and first molar) using a digital caliper. Linear mixed-effects models and generalized linear mixed-effects models with a gamma distribution were used for statistical analysis. Estimated marginal means (EMMs) and 95% confidence intervals (CIs) were derived from the fitted models to summarize group-level thickness estimates. Post-hoc pairwise comparisons were performed using Tukey's test, with significance set at p < 0.05. Results: EMM thickness decreased progressively with increasing MBH: 446 µm (95% CI 432–460) at MBH 2 mm, 386 µm (95% CI 374–399) at MBH 4 mm, 329 µm (95% CI 319–340) at MBH 6 mm, and 268 µm (95% CI 260–277) at MBH 8 mm (all pairwise comparisons p < 0.001). This decreasing trend was consistent across all tooth types and measurement sites, though the magnitude of reduction varied by site. Palatal sites consistently exhibited greater thickness than facial sites. For most tooth type–site combinations, all MBH contrasts were statistically significant, with limited exceptions observed at specific sites for anterior teeth, molars, and premolars. Conclusions: Increasing MBH resulted in a progressive reduction in the thickness of thermoformed Zendura FLX dual-layer clear aligners across all tooth types and measurement sites. Among the four levels tested, an MBH of approximately 4 mm appeared to provide a more balanced thickness distribution. These findings suggest that MBH should be considered as an important fabrication parameter in clear aligner production.
- 18 September 2026
- Published by Frontiers Media SA in Frontiers in Dental Medicine
- Vol. 7, 1889969
Open AccessEffect of 3D-printed model base height on thickness distribution of thermoformed zendura FLX dual-layer clear aligners: an in vitro study
Background: Thermoforming of clear aligners causes non-uniform material thinning that may influence the structural and mechanical characteristics of the aligners. While greater model base height (MBH) has been shown to increase thinning in single-layer aligners, its effect on dual-layer materials remains unclear. This study aimed to evaluate the effect of four MBH levels (2, 4, 6, and 8 mm) on the thickness distribution of thermoformed Zendura FLX dual-layer clear aligners. Methods: Forty Zendura FLX aligners were thermoformed over standardized 3D-printed maxillary models with MBH of 2, 4, 6, and 8 mm ( n = 10 per group). Thickness was measured at multiple tooth-specific sites across four representative teeth (central incisor, canine, first premolar, and first molar) using a digital caliper. Linear mixed-effects models and generalized linear mixed-effects models with a gamma distribution were used for statistical analysis. Estimated marginal means (EMMs) and 95% confidence intervals (CIs) were derived from the fitted models to summarize group-level thickness estimates. Post-hoc pairwise comparisons were performed using Tukey's test, with significance set at p < 0.05. Results: EMM thickness decreased progressively with increasing MBH: 446 µm (95% CI 432–460) at MBH 2 mm, 386 µm (95% CI 374–399) at MBH 4 mm, 329 µm (95% CI 319–340) at MBH 6 mm, and 268 µm (95% CI 260–277) at MBH 8 mm (all pairwise comparisons p < 0.001). This decreasing trend was consistent across all tooth types and measurement sites, though the magnitude of reduction varied by site. Palatal sites consistently exhibited greater thickness than facial sites. For most tooth type–site combinations, all MBH contrasts were statistically significant, with limited exceptions observed at specific sites for anterior teeth, molars, and premolars. Conclusions: Increasing MBH resulted in a progressive reduction in the thickness of thermoformed Zendura FLX dual-layer clear aligners across all tooth types and measurement sites. Among the four levels tested, an MBH of approximately 4 mm appeared to provide a more balanced thickness distribution. These findings suggest that MBH should be considered as an important fabrication parameter in clear aligner production.
- Open Access
- 27 August 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Procedural accuracy and efficiency of 3D versus conventional dental microscopes in novice users
This study compared procedural performance and user experience under three visualization conditions: unaided vision, dental operating microscope (DOM), and three-dimensional dental operating microscope (3D-DOM). In this experimental repeated-measures study, thirty dental students performed a targeting task in randomized order using a DOM (Flexion Advanced, CJ-Optik, Germany) and a 3D-DOM (Promise Vision 3D™, Seiler, USA) at 8× magnification, with a two-week washout period. Accuracy (0–4 scale), task time, and participant-reported outcomes (CVI-S = 0.90) were assessed. Data were analyzed using repeated-measures ANOVA, Friedman test, Bonferroni-adjusted post hoc comparisons, and Spearman correlation ( p < 0.05). Magnification significantly improved procedural accuracy compared to unaided vision ( p < 0.001). The DOM achieved the highest accuracy (3.40 ± 0.30), required the longest task time (5.14 ± 1.70 min) and provided the greatest visual clarity, although 13.3% of participants reported image splitting with greater difficulty in spatial orientation. In contrast, the 3D-DOM demonstrated a more balanced performance between accuracy and efficiency (3.36 ± 0.20; 3.20 ± 0.81 min), with improved spatial orientation, reduced visual discomfort, and the most favorable ergonomic outcomes ( p < 0.05). These findings indicate that while DOM optimizes visual precision, 3D-DOM achieves a more favorable balance between efficiency, usability, and operator ergonomics.
- 27 August 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessProcedural accuracy and efficiency of 3D versus conventional dental microscopes in novice users
This study compared procedural performance and user experience under three visualization conditions: unaided vision, dental operating microscope (DOM), and three-dimensional dental operating microscope (3D-DOM). In this experimental repeated-measures study, thirty dental students performed a targeting task in randomized order using a DOM (Flexion Advanced, CJ-Optik, Germany) and a 3D-DOM (Promise Vision 3D™, Seiler, USA) at 8× magnification, with a two-week washout period. Accuracy (0–4 scale), task time, and participant-reported outcomes (CVI-S = 0.90) were assessed. Data were analyzed using repeated-measures ANOVA, Friedman test, Bonferroni-adjusted post hoc comparisons, and Spearman correlation ( p < 0.05). Magnification significantly improved procedural accuracy compared to unaided vision ( p < 0.001). The DOM achieved the highest accuracy (3.40 ± 0.30), required the longest task time (5.14 ± 1.70 min) and provided the greatest visual clarity, although 13.3% of participants reported image splitting with greater difficulty in spatial orientation. In contrast, the 3D-DOM demonstrated a more balanced performance between accuracy and efficiency (3.36 ± 0.20; 3.20 ± 0.81 min), with improved spatial orientation, reduced visual discomfort, and the most favorable ergonomic outcomes ( p < 0.05). These findings indicate that while DOM optimizes visual precision, 3D-DOM achieves a more favorable balance between efficiency, usability, and operator ergonomics.
- Open Access
- 4 August 2026
- Published by Scientific Scholar in APOS Trends in Orthodontics
- Vol. 16, 260-266
Thermoforming time variability in clear aligner fabrication: A pilot in vitro study
Objectives: Thermoforming time is a key process parameter in the fabrication of clear orthodontic aligners. Manufacturer-recommended heating durations, however, may not reflect changes in heating time during consecutive thermoforming cycles. This study investigated variations in thermoforming time across repeated forming cycles to support optimization of in-house clear aligner fabrication protocols. Material and Methods: In this in vitro study, 100 Zendura FLX thermoplastic sheets (0.76 mm) were thermoformed in five independent sessions, each comprising 20 consecutive cycles, using a Drufomat Scan pressure-forming unit initiated from a cold-start condition. Heating was manually terminated at a standardized sheet deflection of 16 mm, based on preliminary pilot testing, monitored using a parallel laser guidance system. Heating duration was recorded for each cycle. Data were analyzed using a linear mixed-effects model with Bonferroni-adjusted post hoc comparisons. Thermal stabilization was defined as the earliest cycle at which no significant difference in heating time was observed between consecutive cycles ( p > 0.05). Linear regression analysis was applied to characterize heating-time reduction before stabilization. Results: Heating duration ranged from 60.2 to 111.6 s across all cycles. Heating time decreased markedly during the first five cycles and stabilized from the sixth cycle onward ( p > 0.05). During the steady-state phase, the mean heating time was 64.41 ± 3.06 s, remaining significantly longer than the manufacturer-recommended value of 50 s ( p < 0.0001). Linear regression showed a significant reduction in heating time during the pre-stabilization phase (8.56 s/cycle; R 2 = 0.77). Conclusion: Thermoforming time decreased during early fabrication cycles due to cumulative heat retention within the thermoforming unit. Even after thermal stabilization, heating durations exceeded manufacturer-recommended values. These findings indicate that preset heating times should be regarded as reference values and experimentally adjusted according to material and machine-specific behavior.
- 4 August 2026
- Published by Scientific Scholar in APOS Trends in Orthodontics
- Vol. 16, 260-266
Open AccessThermoforming time variability in clear aligner fabrication: A pilot in vitro study
Objectives: Thermoforming time is a key process parameter in the fabrication of clear orthodontic aligners. Manufacturer-recommended heating durations, however, may not reflect changes in heating time during consecutive thermoforming cycles. This study investigated variations in thermoforming time across repeated forming cycles to support optimization of in-house clear aligner fabrication protocols. Material and Methods: In this in vitro study, 100 Zendura FLX thermoplastic sheets (0.76 mm) were thermoformed in five independent sessions, each comprising 20 consecutive cycles, using a Drufomat Scan pressure-forming unit initiated from a cold-start condition. Heating was manually terminated at a standardized sheet deflection of 16 mm, based on preliminary pilot testing, monitored using a parallel laser guidance system. Heating duration was recorded for each cycle. Data were analyzed using a linear mixed-effects model with Bonferroni-adjusted post hoc comparisons. Thermal stabilization was defined as the earliest cycle at which no significant difference in heating time was observed between consecutive cycles ( p > 0.05). Linear regression analysis was applied to characterize heating-time reduction before stabilization. Results: Heating duration ranged from 60.2 to 111.6 s across all cycles. Heating time decreased markedly during the first five cycles and stabilized from the sixth cycle onward ( p > 0.05). During the steady-state phase, the mean heating time was 64.41 ± 3.06 s, remaining significantly longer than the manufacturer-recommended value of 50 s ( p < 0.0001). Linear regression showed a significant reduction in heating time during the pre-stabilization phase (8.56 s/cycle; R 2 = 0.77). Conclusion: Thermoforming time decreased during early fabrication cycles due to cumulative heat retention within the thermoforming unit. Even after thermal stabilization, heating durations exceeded manufacturer-recommended values. These findings indicate that preset heating times should be regarded as reference values and experimentally adjusted according to material and machine-specific behavior.
- Open Access
- 8 July 2026
- Published by Frontiers Media SA in Frontiers in Oral Health
- Vol. 7, 1881161
Retentive force of thermoformed and direct 3D-printed clear aligners with different margin designs and attachments: an in vitro study
Introduction: Clear aligner retention is essential for maintaining appliance stability, intimate aligner fit, and effective orthodontic force delivery. With the increasing interest in direct 3D-printed aligners (DPA), comparative evidence on their retention behavior relative to conventional thermoformed aligners (TFA) under different design conditions remains limited. Objective: This in vitro study aimed to compare the retentive force of TFA and DPA under different margin designs and attachment conditions. Methods: A total of 72 aligners were fabricated using two Methods: thermoforming with Zendura VIVA, 0.89 mm, and direct 3D printing with Tera Harz TC-85DAC, designed thickness 0.50 mm. Specimens were assigned to 12 groups according to fabrication method, attachment condition (NA or YA), and margin design: Straight 2 mm, Straight 0 mm, or Scalloped 0 mm. Retentive force was measured using a universal testing machine at a crosshead speed of 5 mm/min. Each aligner was tested five times. Group comparisons were performed using the Mann–Whitney U -test and Kruskal–Wallis test, with significance set at p < 0.05. Results: TFA generally demonstrated higher retentive force than DPA, but lower retentive force in the Scalloped 0 mm design without attachments. The Straight 2 mm design produced the highest retentive force across groups, whereas the Scalloped 0 mm design showed the lowest values. The highest mean retentive force was observed in the TFA-YA Straight 2 mm group (26.18 ± 1.67 N), and the lowest in the TFA-NA Scalloped 0 mm group (3.25 ± 0.94 N). Attachments increased retentive force in most conditions, with a pronounced effect in the Scalloped 0 mm design. Conclusion: Clear aligner retention varied according to fabrication method, margin design, attachment condition, and material-related characteristics. Individualized aligner design may help optimize retention and improve biomechanical performance in clear aligner therapy.
- 8 July 2026
- Published by Frontiers Media SA in Frontiers in Oral Health
- Vol. 7, 1881161
Open AccessRetentive force of thermoformed and direct 3D-printed clear aligners with different margin designs and attachments: an in vitro study
Introduction: Clear aligner retention is essential for maintaining appliance stability, intimate aligner fit, and effective orthodontic force delivery. With the increasing interest in direct 3D-printed aligners (DPA), comparative evidence on their retention behavior relative to conventional thermoformed aligners (TFA) under different design conditions remains limited. Objective: This in vitro study aimed to compare the retentive force of TFA and DPA under different margin designs and attachment conditions. Methods: A total of 72 aligners were fabricated using two Methods: thermoforming with Zendura VIVA, 0.89 mm, and direct 3D printing with Tera Harz TC-85DAC, designed thickness 0.50 mm. Specimens were assigned to 12 groups according to fabrication method, attachment condition (NA or YA), and margin design: Straight 2 mm, Straight 0 mm, or Scalloped 0 mm. Retentive force was measured using a universal testing machine at a crosshead speed of 5 mm/min. Each aligner was tested five times. Group comparisons were performed using the Mann–Whitney U -test and Kruskal–Wallis test, with significance set at p < 0.05. Results: TFA generally demonstrated higher retentive force than DPA, but lower retentive force in the Scalloped 0 mm design without attachments. The Straight 2 mm design produced the highest retentive force across groups, whereas the Scalloped 0 mm design showed the lowest values. The highest mean retentive force was observed in the TFA-YA Straight 2 mm group (26.18 ± 1.67 N), and the lowest in the TFA-NA Scalloped 0 mm group (3.25 ± 0.94 N). Attachments increased retentive force in most conditions, with a pronounced effect in the Scalloped 0 mm design. Conclusion: Clear aligner retention varied according to fabrication method, margin design, attachment condition, and material-related characteristics. Individualized aligner design may help optimize retention and improve biomechanical performance in clear aligner therapy.
- Open Access
- 1 June 2026
- Published by Frontiers Media SA in Frontiers in Dental Medicine
- Vol. 7, 1863922
Thickness distribution and site-specific variability of thermoformed multilayer clear aligners: an in vitro study
Introduction: Thermoforming is a critical step in the fabrication of clear aligners and is associated with non-uniform deformation of thermoplastic materials, resulting in non-uniform thickness distribution. Because aligner thickness directly influences stiffness and force delivery, such variability may affect the accuracy and predictability of orthodontic treatment. Aim: This study aimed to evaluate the thickness distribution of thermoformed clear aligners across different tooth regions and anatomical sites, with a focus on identifying patterns of non-uniform material thinning. Methods: Ten thermoformed aligners fabricated from 760 µm multilayer thermoplastic sheets (Zendura FLX) were analyzed in vitro . Thickness measurements were obtained using a calibrated digital caliper at standardized anatomical reference points across anterior, canine, premolar, and molar regions. Generalized estimating equations (GEE) with robust standard errors were used to account for repeated measurements within the same aligner, and pairwise comparisons were adjusted using the Bonferroni correction. Results: Significant differences in thickness were observed among tooth regions ( p < 0.001), with the lowest values in anterior teeth (404.0 ± 5.9 µm) and the highest in molars (481.6 ± 6.0 µm). Thickness reduction ranged from approximately 36% to 47% relative to the original material. Site-specific analysis demonstrated that the facial regions generally exhibited lower thickness values than corresponding palatal regions, indicating non-uniform thermoforming-induced deformation patterns. These findings demonstrated that anatomical location was a major determinant of thickness variability. Conclusion: Thermoformed clear aligners exhibit pronounced and systematic non-uniform thickness distribution strongly influenced by tooth morphology and local geometry characteristics. This non-uniform thickness distribution may contribute to variations in force delivery and should be considered in aligner design and clinical application.
- 1 June 2026
- Published by Frontiers Media SA in Frontiers in Dental Medicine
- Vol. 7, 1863922
Open AccessThickness distribution and site-specific variability of thermoformed multilayer clear aligners: an in vitro study
Introduction: Thermoforming is a critical step in the fabrication of clear aligners and is associated with non-uniform deformation of thermoplastic materials, resulting in non-uniform thickness distribution. Because aligner thickness directly influences stiffness and force delivery, such variability may affect the accuracy and predictability of orthodontic treatment. Aim: This study aimed to evaluate the thickness distribution of thermoformed clear aligners across different tooth regions and anatomical sites, with a focus on identifying patterns of non-uniform material thinning. Methods: Ten thermoformed aligners fabricated from 760 µm multilayer thermoplastic sheets (Zendura FLX) were analyzed in vitro . Thickness measurements were obtained using a calibrated digital caliper at standardized anatomical reference points across anterior, canine, premolar, and molar regions. Generalized estimating equations (GEE) with robust standard errors were used to account for repeated measurements within the same aligner, and pairwise comparisons were adjusted using the Bonferroni correction. Results: Significant differences in thickness were observed among tooth regions ( p < 0.001), with the lowest values in anterior teeth (404.0 ± 5.9 µm) and the highest in molars (481.6 ± 6.0 µm). Thickness reduction ranged from approximately 36% to 47% relative to the original material. Site-specific analysis demonstrated that the facial regions generally exhibited lower thickness values than corresponding palatal regions, indicating non-uniform thermoforming-induced deformation patterns. These findings demonstrated that anatomical location was a major determinant of thickness variability. Conclusion: Thermoformed clear aligners exhibit pronounced and systematic non-uniform thickness distribution strongly influenced by tooth morphology and local geometry characteristics. This non-uniform thickness distribution may contribute to variations in force delivery and should be considered in aligner design and clinical application.
- Open Access
- 25 May 2026
- Published by Frontiers Media SA in Frontiers in Dental Medicine
- Vol. 7, 1839221
A reproducible optical–microscopic framework for evaluating electronic apex locator performance in different irrigants using 3D-printed transparent resin teeth
This study presents a standardized experimental framework for assessing the different modes of locating the apical foramen in EAL-integrated endodontic motors using 3D-printed transparent resin teeth in two electrolyte solutions. Ten extracted human premolars were scanned using cone-beam computed tomography and replicated to produce 100 transparent resin tooth models. Root canal length determination was performed under static and dynamic conditions using two EAL-integrated endodontic motors in sodium chloride and chlorhexidine solutions. A dual optical microscope system enabled micron-level positional recording of the file tip relative to the apical terminus, independent of the electronic readout. Extracted human teeth served as reference specimens for validation. High agreement was observed among different operating modes of the endodontic motors, with no significant differences between irrigation solutions. Measurements demonstrated high repeatability and consistency across static and dynamic conditions. The proposed framework enables direct, objective, and reproducible evaluation of EAL performance by combining anatomical standardization with high-precision optical measurement. Transparent resin teeth allow continuous visualization of file behavior, facilitating assessment of dynamic motor functions that are difficult to quantify using conventional approaches. This framework provides a scalable platform for preclinical device evaluation, methodological validation, and simulation-based endodontic education.
- 25 May 2026
- Published by Frontiers Media SA in Frontiers in Dental Medicine
- Vol. 7, 1839221
Open AccessA reproducible optical–microscopic framework for evaluating electronic apex locator performance in different irrigants using 3D-printed transparent resin teeth
This study presents a standardized experimental framework for assessing the different modes of locating the apical foramen in EAL-integrated endodontic motors using 3D-printed transparent resin teeth in two electrolyte solutions. Ten extracted human premolars were scanned using cone-beam computed tomography and replicated to produce 100 transparent resin tooth models. Root canal length determination was performed under static and dynamic conditions using two EAL-integrated endodontic motors in sodium chloride and chlorhexidine solutions. A dual optical microscope system enabled micron-level positional recording of the file tip relative to the apical terminus, independent of the electronic readout. Extracted human teeth served as reference specimens for validation. High agreement was observed among different operating modes of the endodontic motors, with no significant differences between irrigation solutions. Measurements demonstrated high repeatability and consistency across static and dynamic conditions. The proposed framework enables direct, objective, and reproducible evaluation of EAL performance by combining anatomical standardization with high-precision optical measurement. Transparent resin teeth allow continuous visualization of file behavior, facilitating assessment of dynamic motor functions that are difficult to quantify using conventional approaches. This framework provides a scalable platform for preclinical device evaluation, methodological validation, and simulation-based endodontic education.
- Open Access
- 6 April 2026
- Published by Vietnam Medical Journal, Vietnam Medical Association in Tạp chí Y học Việt Nam
- Vol. 560 (2)
ẢNH HƯỞNG CỦA YẾU TỐ CHIỀU ĐỨNG XƯƠNG HÀM, SỌ MẶT ĐẾN TƯƠNG QUAN R6 HẠNG II: NGHIÊN CỨU DỌC TỪ BỘ RĂNG SỮA ĐẾN BỘ RĂNG VĨNH VIỄN
Đặt vấn đề: Theo phân loại Angle, tương quan răng cối lớn thứ nhất gồm ba dạng, trong đó hạng I được xem là bình thường và hạng II và III được xem là bất thường. Sai khớp cắn hạng II là dạng có tỷ lệ hiện mắc cao, liên quan các yếu tố răng, cung răng, xương hàm, sọ mặt và sự tăng trưởng. Nhiều tác giả ghi nhận hạng II không chỉ là sai lệch theo chiều trước – sau mà còn liên quan đến yếu tố chiều đứng của xương hàm và sọ mặt. Tuy nhiên, các nghiên cứu dọc về vai trò những yếu tố này đối với sự hình thành tương quan R6 hạng II ở bộ răng vĩnh viễn còn hạn chế; tại Việt Nam chưa có nghiên cứu trên người Việt. Do đó, chúng tôi thực hiện nghiên cứu dọc từ bộ răng sữa đến bộ răng vĩnh viễn nhằm đánh giá ảnh hưởng của yếu tố chiều đứng xương hàm, sọ mặt đến sự hình thành tương quan R6 hạng II. Mục tiêu: Đánh giá các thông số chiều cao mặt và tỉ lệ giữa chiều cao các tầng mặt ở từng giai đoạn bộ răng sữa (T1), bộ răng hỗn hợp (T2) và bộ răng vĩnh viễn (T3) và sự tăng trưởng của các yếu tố này từ T1 đến T2 và từ T2 đến T3 ở nhóm có tương quan R6 hạng II so với nhóm có tương quan R6 hạng I ở bộ răng vĩnh viễn. Đối tượng và phương pháp: Đối tượng nghiên cứu gồm 25 trẻ (50 phần hàm) được theo dõi dọc hồi cứu từ giai đoạn T1 đến T2 và T3, mỗi trẻ có 3 cặp mẫu hàm ở T1, T2, T3 và 3 phim sọ nghiêng cùng giai đoạn với mẫu hàm. Nghiên cứu đánh giá 20 biến số về chiều cao toàn bộ tầng mặt (CCM), chiều cao tầng mặt giữa (TMG), tầng mặt dưới (TMD), tỉ lệ chiều cao tầng mặt giữa với tầng mặt dưới (TMG/TMD) ở từng giai đoạn T1, T2, T3 và sự tăng trưởng của các yếu tố này từ T1 đến T2 và từ T2 đến T3. Nghiên cứu đánh giá ảnh hưởng của các yếu tố này đến tương quan R6 hạng II ở bộ răng vĩnh viễn. Kết quả: Nhóm sai khớp cắn hạng II có tầng mặt giữa lớn hơn, tầng mặt dưới nhỏ hơn làm cho tỉ lệ giữa chiều cao tầng mặt giữa và tầng mặt dưới lớn hơn ở T2 và T3 và tỉ lệ này tăng nhiều từ T2-T3 so với nhóm có tương quan khớp cắn hạng I bình thường.
- 6 April 2026
- Published by Vietnam Medical Journal, Vietnam Medical Association in Tạp chí Y học Việt Nam
- Vol. 560 (2)
Open AccessẢNH HƯỞNG CỦA YẾU TỐ CHIỀU ĐỨNG XƯƠNG HÀM, SỌ MẶT ĐẾN TƯƠNG QUAN R6 HẠNG II: NGHIÊN CỨU DỌC TỪ BỘ RĂNG SỮA ĐẾN BỘ RĂNG VĨNH VIỄN
Đặt vấn đề: Theo phân loại Angle, tương quan răng cối lớn thứ nhất gồm ba dạng, trong đó hạng I được xem là bình thường và hạng II và III được xem là bất thường. Sai khớp cắn hạng II là dạng có tỷ lệ hiện mắc cao, liên quan các yếu tố răng, cung răng, xương hàm, sọ mặt và sự tăng trưởng. Nhiều tác giả ghi nhận hạng II không chỉ là sai lệch theo chiều trước – sau mà còn liên quan đến yếu tố chiều đứng của xương hàm và sọ mặt. Tuy nhiên, các nghiên cứu dọc về vai trò những yếu tố này đối với sự hình thành tương quan R6 hạng II ở bộ răng vĩnh viễn còn hạn chế; tại Việt Nam chưa có nghiên cứu trên người Việt. Do đó, chúng tôi thực hiện nghiên cứu dọc từ bộ răng sữa đến bộ răng vĩnh viễn nhằm đánh giá ảnh hưởng của yếu tố chiều đứng xương hàm, sọ mặt đến sự hình thành tương quan R6 hạng II. Mục tiêu: Đánh giá các thông số chiều cao mặt và tỉ lệ giữa chiều cao các tầng mặt ở từng giai đoạn bộ răng sữa (T1), bộ răng hỗn hợp (T2) và bộ răng vĩnh viễn (T3) và sự tăng trưởng của các yếu tố này từ T1 đến T2 và từ T2 đến T3 ở nhóm có tương quan R6 hạng II so với nhóm có tương quan R6 hạng I ở bộ răng vĩnh viễn. Đối tượng và phương pháp: Đối tượng nghiên cứu gồm 25 trẻ (50 phần hàm) được theo dõi dọc hồi cứu từ giai đoạn T1 đến T2 và T3, mỗi trẻ có 3 cặp mẫu hàm ở T1, T2, T3 và 3 phim sọ nghiêng cùng giai đoạn với mẫu hàm. Nghiên cứu đánh giá 20 biến số về chiều cao toàn bộ tầng mặt (CCM), chiều cao tầng mặt giữa (TMG), tầng mặt dưới (TMD), tỉ lệ chiều cao tầng mặt giữa với tầng mặt dưới (TMG/TMD) ở từng giai đoạn T1, T2, T3 và sự tăng trưởng của các yếu tố này từ T1 đến T2 và từ T2 đến T3. Nghiên cứu đánh giá ảnh hưởng của các yếu tố này đến tương quan R6 hạng II ở bộ răng vĩnh viễn. Kết quả: Nhóm sai khớp cắn hạng II có tầng mặt giữa lớn hơn, tầng mặt dưới nhỏ hơn làm cho tỉ lệ giữa chiều cao tầng mặt giữa và tầng mặt dưới lớn hơn ở T2 và T3 và tỉ lệ này tăng nhiều từ T2-T3 so với nhóm có tương quan khớp cắn hạng I bình thường.
- Open Access
- 29 October 2025
- Published by Vietnam Medical Journal, Vietnam Medical Association in Tạp chí Y học Việt Nam
- Vol. 555 (1)
ẢNH HƯỞNG CỦA VIỆC SỬ DỤNG KÍNH HIỂN VI ĐẾN ĐỘ CHÍNH XÁC VÀ THỜI GIAN THAO TÁC TRONG THỰC HÀNH NỘI NHA
Mục tiêu: Nghiên cứu nhằm đánh giá ảnh hưởng của kính hiển vi nha khoa đến độ chính xác và thời gian thao tác trong môi trường mô phỏng nội nha, đồng thời so sánh sự khác biệt giữa nhóm sinh viên và bác sĩ sau đại học. Đối tượng & phương pháp nghiên cứu: Nghiên cứu cắt ngang phân tích được tiến hành trên 50 đối tượng (25 sinh viên, 25 bác sĩ) chưa có kinh nghiệm sử dụng thiết bị phóng đại trong điều trị lâm sàng Tất cả được huấn luyện 6 giờ trước thử nghiệm và thực hiện thao tác đâm trâm vào các mục tiêu bố trí theo cung răng trên phantom, dưới hai điều kiện: không sử dụng và có sử dụng kính hiển vi. Độ chính xác được đánh giá theo thang điểm của Bowers (0–4) và thời gian thực hiện được ghi nhận. Kết quả: Độ chính xác thao tác tăng rõ rệt từ mắt thường đến kính hiển vi ở cả bác sĩ (2.41 ± 0.41 so với 3.50 ± 0.14) và sinh viên (2.44 ± 0.39 so với 3.49 ± 0.11), với p < 0.001. Thời gian thực hiện cũng kéo dài đáng kể từ mắt thường đến kính hiển vi (bác sĩ: 3.23 ± 0.82 phút so với 7.08 ± 1.70 phút; sinh viên: 3.08 ± 0.89 phút so với 8.10 ± 2.71 phút; p < 0.001). Không có khác biệt ý nghĩa giữa hai nhóm trong cùng điều kiện. Kết luận: Kính hiển vi cải thiện đáng kể độ chính xác thao tác nhưng đồng thời làm gia tăng thời gian thực hiện. Việc tích hợp kính hiển vi vào chương trình đào tạo tiền lâm sàng có tiềm năng nâng cao kỹ năng thao tác, hỗ trợ thực hành lâm sàng và cải thiện công thái học cho bác sĩ răng hàm mặt.
- 29 October 2025
- Published by Vietnam Medical Journal, Vietnam Medical Association in Tạp chí Y học Việt Nam
- Vol. 555 (1)
Open AccessẢNH HƯỞNG CỦA VIỆC SỬ DỤNG KÍNH HIỂN VI ĐẾN ĐỘ CHÍNH XÁC VÀ THỜI GIAN THAO TÁC TRONG THỰC HÀNH NỘI NHA
Mục tiêu: Nghiên cứu nhằm đánh giá ảnh hưởng của kính hiển vi nha khoa đến độ chính xác và thời gian thao tác trong môi trường mô phỏng nội nha, đồng thời so sánh sự khác biệt giữa nhóm sinh viên và bác sĩ sau đại học. Đối tượng & phương pháp nghiên cứu: Nghiên cứu cắt ngang phân tích được tiến hành trên 50 đối tượng (25 sinh viên, 25 bác sĩ) chưa có kinh nghiệm sử dụng thiết bị phóng đại trong điều trị lâm sàng Tất cả được huấn luyện 6 giờ trước thử nghiệm và thực hiện thao tác đâm trâm vào các mục tiêu bố trí theo cung răng trên phantom, dưới hai điều kiện: không sử dụng và có sử dụng kính hiển vi. Độ chính xác được đánh giá theo thang điểm của Bowers (0–4) và thời gian thực hiện được ghi nhận. Kết quả: Độ chính xác thao tác tăng rõ rệt từ mắt thường đến kính hiển vi ở cả bác sĩ (2.41 ± 0.41 so với 3.50 ± 0.14) và sinh viên (2.44 ± 0.39 so với 3.49 ± 0.11), với p < 0.001. Thời gian thực hiện cũng kéo dài đáng kể từ mắt thường đến kính hiển vi (bác sĩ: 3.23 ± 0.82 phút so với 7.08 ± 1.70 phút; sinh viên: 3.08 ± 0.89 phút so với 8.10 ± 2.71 phút; p < 0.001). Không có khác biệt ý nghĩa giữa hai nhóm trong cùng điều kiện. Kết luận: Kính hiển vi cải thiện đáng kể độ chính xác thao tác nhưng đồng thời làm gia tăng thời gian thực hiện. Việc tích hợp kính hiển vi vào chương trình đào tạo tiền lâm sàng có tiềm năng nâng cao kỹ năng thao tác, hỗ trợ thực hành lâm sàng và cải thiện công thái học cho bác sĩ răng hàm mặt.
- Open Access
- 19 September 2025
- Published by Vietnam Medical Journal, Vietnam Medical Association in Tạp chí Y học Việt Nam
- Vol. 553 (3)
SỰ CẦN THIẾT CAN THIỆP CHỈNH NHA SỚM TRÊN TRẺ CÓ TƯƠNG QUAN RĂNG 6 DẠNG ĐỐI ĐỈNH Ở BỘ RĂNG HỖN HỢP
Mở đầu: Tương quan răng cối lớn thứ nhất dạng đối đỉnh (hạng II 50% theo Angle) là một hình thái phổ biến và được xem là bình thường ở giai đoạn bộ răng hỗn hợp. Tuy nhiên, dạng này có thể diễn tiến thành tương quan bất thường ở bộ răng vĩnh viễn nếu không được theo dõi và can thiệp sớm. Tại Việt Nam, chưa có nghiên cứu dọc nào đánh giá sự thay đổi tương quan dạng này từ bộ răng hỗn hợp đến bộ răng vĩnh viễn. Mục tiêu: Đánh giá diễn tiến hình thái khớp cắn ở nhóm có tương quan R6 dạng đối đỉnh từ bộ răng hỗn hợp đến bộ răng vĩnh viễn. Phương pháp: Thiết kế nghiên cứu dọc hồi cứu trên 112 phần hàm có tương quan R6 đối đỉnh ở giai đoạn hỗn hợp sớm. Tương quan R6 được đánh giá tại hai thời điểm: T2 (bộ răng hỗn hợp) và T3 (bộ răng vĩnh viễn). Tương quan R6 được phân loại theo tiêu chí của Angle, trong đó ở T2 chỉ có dạng đối đỉnh mới được chọn vào nghiên cứu. Ở T3, tương quan R6 được phân loại thành 3 dạng: hạng I, hạng II và hạng III. Kết quả: Trong số 112 phần hàm ban đầu có tương quan R6 dạng đối đỉnh ở T2, có 84 phần hàm (75%) chuyển thành tương quan R6 hạng I và 28 phần hàm (25%) chuyển thành hạng II ở T3. Kết luận: Tương quan R6 dạng đối đỉnh ở bộ răng hỗn hợp có khả năng tự điều chỉnh thành tương quan hạng I ở đa số trường hợp. Tuy nhiên, vẫn có khoảng 25% tiến triển thành khớp cắn hạng II. Do đó, cần sàng lọc và theo dõi nhóm có nguy cơ cao để can thiệp sớm, hướng đến tương quan khớp cắn lý tưởng ở bộ răng vĩnh viễn.
- 19 September 2025
- Published by Vietnam Medical Journal, Vietnam Medical Association in Tạp chí Y học Việt Nam
- Vol. 553 (3)
Open AccessSỰ CẦN THIẾT CAN THIỆP CHỈNH NHA SỚM TRÊN TRẺ CÓ TƯƠNG QUAN RĂNG 6 DẠNG ĐỐI ĐỈNH Ở BỘ RĂNG HỖN HỢP
Mở đầu: Tương quan răng cối lớn thứ nhất dạng đối đỉnh (hạng II 50% theo Angle) là một hình thái phổ biến và được xem là bình thường ở giai đoạn bộ răng hỗn hợp. Tuy nhiên, dạng này có thể diễn tiến thành tương quan bất thường ở bộ răng vĩnh viễn nếu không được theo dõi và can thiệp sớm. Tại Việt Nam, chưa có nghiên cứu dọc nào đánh giá sự thay đổi tương quan dạng này từ bộ răng hỗn hợp đến bộ răng vĩnh viễn. Mục tiêu: Đánh giá diễn tiến hình thái khớp cắn ở nhóm có tương quan R6 dạng đối đỉnh từ bộ răng hỗn hợp đến bộ răng vĩnh viễn. Phương pháp: Thiết kế nghiên cứu dọc hồi cứu trên 112 phần hàm có tương quan R6 đối đỉnh ở giai đoạn hỗn hợp sớm. Tương quan R6 được đánh giá tại hai thời điểm: T2 (bộ răng hỗn hợp) và T3 (bộ răng vĩnh viễn). Tương quan R6 được phân loại theo tiêu chí của Angle, trong đó ở T2 chỉ có dạng đối đỉnh mới được chọn vào nghiên cứu. Ở T3, tương quan R6 được phân loại thành 3 dạng: hạng I, hạng II và hạng III. Kết quả: Trong số 112 phần hàm ban đầu có tương quan R6 dạng đối đỉnh ở T2, có 84 phần hàm (75%) chuyển thành tương quan R6 hạng I và 28 phần hàm (25%) chuyển thành hạng II ở T3. Kết luận: Tương quan R6 dạng đối đỉnh ở bộ răng hỗn hợp có khả năng tự điều chỉnh thành tương quan hạng I ở đa số trường hợp. Tuy nhiên, vẫn có khoảng 25% tiến triển thành khớp cắn hạng II. Do đó, cần sàng lọc và theo dõi nhóm có nguy cơ cao để can thiệp sớm, hướng đến tương quan khớp cắn lý tưởng ở bộ răng vĩnh viễn.
- Open Access
- 19 September 2025
- Published by Vietnam Medical Journal, Vietnam Medical Association in Tạp chí Y học Việt Nam
- Vol. 553 (3)
ẢNH HƯỞNG CỦA KHOẢNG E ĐẾN TƯƠNG QUAN RĂNG CỐI LỚN THỨ NHẤT: NGHIÊN CỨU DỌC TỪ BỘ RĂNG HỖN HỢP ĐẾN VĨNH VIỄN
Giới thiệu: Tương quan theo chiều trước sau của răng cối lớn vĩnh viễn thứ nhất (R6) là yếu tố rất quan trọng trong đánh giá khớp cắn của bộ răng. Trong giai đoạn bộ răng hỗn hợp, theo y văn có hai yếu tố chính đó là sự di gần muộn vào khoảng leeway và tăng trưởng khác biệt giữa xương hàm trên và xương hàm dưới sẽ ảnh hưởng đến tương quan theo chiều trước sau của R6. Khoảng leeway (hiệu số giữa tổng kích thước gần -xa các răng 3, 4, 5 sữa và các răng 3, 4, 5 vĩnh viễn thay thế) là yếu tố đã được biết đến rộng rãi trong tương quan với khớp cắn R6 vĩnh viễn. Trong khi đó, khoảng E (hiệu số giữa kích thước gần -xa răng 5 sữa và răng 5 vĩnh viễn tương ứng) là một chỉ số mới, đơn giản, dễ đo và tính toán nhanh hơn khoảng leeway được đề xuất là chỉ số dự đoán, nhưng bằng chứng ở quần thể Việt Nam vẫn còn hạn chế. Phương pháp: Nghiên cứu hồi cứu dọc trên 112 được thực hiện. Các chiều rộng gần–xa được đo bằng thước kẹp kỹ thuật số (độ chính xác ±0,01 mm) để tính khoảng leeway và khoảng E ở cả hàm trên và hàm dưới. Tương quan R6 cuối cùng được phân loại theo tiêu chuẩn của Angle. So sánh giữa nhóm có chuyển từ tương quan R6 đối đỉnh ở bộ răng hỗn hợp thành tương quan R6 hạng I (n = 84) và nhóm thành tương quan R6 hạng II (n = 28) được phân tích bằng kiểm định t và Mann–Whitney (SPSS 22.0). Kết quả: Nghiên cứu cho thấy không có khác biệt có ý nghĩa thống kê về khoảng leeway ở cả hai hàm hoặc khoảng E hàm trên giữa hai nhóm tương quan R6 hạng I và hạng II ở bộ răng vĩnh viễn (p > 0,05). Tuy nhiên, khoảng E hàm dưới nhóm hạng I (2,6 ± 0,5 mm) lớn hơn đáng kể so với nhóm hạng II (2,4 ± 0,5 mm; p < 0,05). Thảo luận: Khoảng E hàm dưới, đơn giản hơn so với khoảng leeway, cho thấy giá trị thống kê như một yếu tố dự đoán kết quả tương quan R6 sẽ phát triển thuận lợi hay bất lợi từ giai đoạn bộ răng hỗn hợp sang bộ răng vĩnh viễn. Cần có thêm các nghiên cứu sâu về khoảng E và vai trò của nó trong sự hình thành và phát triển khớp cắn, cũng như xem xét ứng dụng chỉ số này trong thực hành chỉnh hình dự phòng và can thiệp lâm sàng. Kết luận: Khoảng E hàm dưới ảnh hưởng đáng kể đến việc đạt tương quan răng cối lớn Angle hạng I, nhấn mạnh ưu thế của nó so với khoảng leeway trong dự đoán kết quả khớp cắn trong tương lai.
- 19 September 2025
- Published by Vietnam Medical Journal, Vietnam Medical Association in Tạp chí Y học Việt Nam
- Vol. 553 (3)
Open AccessẢNH HƯỞNG CỦA KHOẢNG E ĐẾN TƯƠNG QUAN RĂNG CỐI LỚN THỨ NHẤT: NGHIÊN CỨU DỌC TỪ BỘ RĂNG HỖN HỢP ĐẾN VĨNH VIỄN
Giới thiệu: Tương quan theo chiều trước sau của răng cối lớn vĩnh viễn thứ nhất (R6) là yếu tố rất quan trọng trong đánh giá khớp cắn của bộ răng. Trong giai đoạn bộ răng hỗn hợp, theo y văn có hai yếu tố chính đó là sự di gần muộn vào khoảng leeway và tăng trưởng khác biệt giữa xương hàm trên và xương hàm dưới sẽ ảnh hưởng đến tương quan theo chiều trước sau của R6. Khoảng leeway (hiệu số giữa tổng kích thước gần -xa các răng 3, 4, 5 sữa và các răng 3, 4, 5 vĩnh viễn thay thế) là yếu tố đã được biết đến rộng rãi trong tương quan với khớp cắn R6 vĩnh viễn. Trong khi đó, khoảng E (hiệu số giữa kích thước gần -xa răng 5 sữa và răng 5 vĩnh viễn tương ứng) là một chỉ số mới, đơn giản, dễ đo và tính toán nhanh hơn khoảng leeway được đề xuất là chỉ số dự đoán, nhưng bằng chứng ở quần thể Việt Nam vẫn còn hạn chế. Phương pháp: Nghiên cứu hồi cứu dọc trên 112 được thực hiện. Các chiều rộng gần–xa được đo bằng thước kẹp kỹ thuật số (độ chính xác ±0,01 mm) để tính khoảng leeway và khoảng E ở cả hàm trên và hàm dưới. Tương quan R6 cuối cùng được phân loại theo tiêu chuẩn của Angle. So sánh giữa nhóm có chuyển từ tương quan R6 đối đỉnh ở bộ răng hỗn hợp thành tương quan R6 hạng I (n = 84) và nhóm thành tương quan R6 hạng II (n = 28) được phân tích bằng kiểm định t và Mann–Whitney (SPSS 22.0). Kết quả: Nghiên cứu cho thấy không có khác biệt có ý nghĩa thống kê về khoảng leeway ở cả hai hàm hoặc khoảng E hàm trên giữa hai nhóm tương quan R6 hạng I và hạng II ở bộ răng vĩnh viễn (p > 0,05). Tuy nhiên, khoảng E hàm dưới nhóm hạng I (2,6 ± 0,5 mm) lớn hơn đáng kể so với nhóm hạng II (2,4 ± 0,5 mm; p < 0,05). Thảo luận: Khoảng E hàm dưới, đơn giản hơn so với khoảng leeway, cho thấy giá trị thống kê như một yếu tố dự đoán kết quả tương quan R6 sẽ phát triển thuận lợi hay bất lợi từ giai đoạn bộ răng hỗn hợp sang bộ răng vĩnh viễn. Cần có thêm các nghiên cứu sâu về khoảng E và vai trò của nó trong sự hình thành và phát triển khớp cắn, cũng như xem xét ứng dụng chỉ số này trong thực hành chỉnh hình dự phòng và can thiệp lâm sàng. Kết luận: Khoảng E hàm dưới ảnh hưởng đáng kể đến việc đạt tương quan răng cối lớn Angle hạng I, nhấn mạnh ưu thế của nó so với khoảng leeway trong dự đoán kết quả khớp cắn trong tương lai.