Heat-actuated valve implementation in a point-of-care, paper-based microfluidic device for infectious disease detection
Open Access
- 15 April 2026
- journal article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (4) , e0344750
Abstract
Paper-based microfluid devices have great potential to perform complex assays like nucleic acid amplification tests (NAATs) in point-of-care (POC) and low resource settings, but have not often succeeded because there is frequently need for affordable and simple solutions to address complex fluidics and sample delivery without risk of contamination. These issues are exacerbated when multiple sample processing procedures must be automated by valve integration in the absence of advanced supportive instrumentation or trained personnel. For NAAT application in remote or home environments, valving within a POC device must facilitate precise fluidic movement and physically separate each chemical processing step. Ideally, the valve should also be affordable, easy to manufacture, robust in varying climate environments, reliable when stored under ambient conditions, affordable, and non-reactive with chemical reagents or samples. Here, we report the design and integration of two adaptable thermally-actuated valves for application in a point-of-care, paper-based rapid analysis device. Both valves are designed to facilitate the fluidic movement and control necessary to enable reverse-transcriptase loop-mediated isothermal amplification (RT-LAMP) reactions in a paper-based device. Each valve could be used independently or alongside the other valve to control fluidic movement at specific locations along the paper fluidic pathway. The valves differ in their material composition, fabrication, and mechanisms for fluidic control, but both are affordable, durable, and simple to use. We demonstrated that each valve could be used to enable RT-LAMP reactions in a paper-based device for detecting either RNA or DNA biomarkers for respiratory infectious diseases (COVID and Flu A) from human nasal swabs.Keywords
Funding Information
- Mercatus Center, George Mason University (Emergent Ventures Fast Grant)
- National Institute of Allergy and Infectious Diseases (FA215700/A177358)
This publication has 43 references indexed in Scilit:
- An electrochemical paper-based hydrogel immunosensor to monitor serum cytokine for predicting the severity of COVID-19 patientsBiosensors and Bioelectronics, 2022
- Paper‐based Wearable Electrochemical Sensors: A New Generation of Analytical DevicesElectroanalysis, 2022
- A thermoresponsive valve to control fluid flow in microfluidic paper-based devicesMicrofluidics and Nanofluidics, 2022
- Recent Advances and Applications in Paper-Based Devices for Point-of-Care TestingJournal of Analysis and Testing, 2022
- Recent advances in microfluidic paper-based assay devices for diagnosis of human diseases using saliva, tears and sweat samplesSensors and Actuators B: Chemical, 2021
- Recent developments in flow modeling and fluid control for paper-based microfluidic biosensorsBiosensors and Bioelectronics, 2021
- Electrochemical paper-based analytical device for multiplexed, point-of-care detection of cardiovascular disease biomarkersSensors and Actuators B: Chemical, 2021
- Two-Fluorophore Mobile Phone Imaging of Biplexed Real-Time NAATs Overcomes Optical Artifacts in Highly Scattering Porous MediaAnalytical Chemistry, 2020
- A low-cost nanomaterial-based electrochemical immunosensor on paper for high-sensitivity early detection of pancreatic cancerSensors and Actuators B: Chemical, 2019
- Evaluation of reverse transcription loop‐mediated isothermal amplification assays for rapid diagnosis of pandemic influenza A/H1N1 2009 virusJournal of Medical Virology, 2010