PYPaul Yager

Paul Yager

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Paul Yager has a total of 86 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Heat-actuated valve implementation in a point-of-care, paper-based microfluidic device for infectious disease detection

    by Kevin P. Jiang, Steven Bennett, Paul Yager

    Paper-based microfluid devices have great potential to perform complex assays like nucleic acid amplification tests (NAATs) in point-of-care (POC) and low resource settings, but have not often succeeded because there is frequently need for affordable and simple solutions to address complex fluidics and sample delivery without risk of contamination. These issues are exacerbated when multiple sample processing procedures must be automated by valve integration in the absence of advanced supportive instrumentation or trained personnel. For NAAT application in remote or home environments, valving within a POC device must facilitate precise fluidic movement and physically separate each chemical processing step. Ideally, the valve should also be affordable, easy to manufacture, robust in varying climate environments, reliable when stored under ambient conditions, affordable, and non-reactive with chemical reagents or samples. Here, we report the design and integration of two adaptable thermally-actuated valves for application in a point-of-care, paper-based rapid analysis device. Both valves are designed to facilitate the fluidic movement and control necessary to enable reverse-transcriptase loop-mediated isothermal amplification (RT-LAMP) reactions in a paper-based device. Each valve could be used independently or alongside the other valve to control fluidic movement at specific locations along the paper fluidic pathway. The valves differ in their material composition, fabrication, and mechanisms for fluidic control, but both are affordable, durable, and simple to use. We demonstrated that each valve could be used to enable RT-LAMP reactions in a paper-based device for detecting either RNA or DNA biomarkers for respiratory infectious diseases (COVID and Flu A) from human nasal swabs.

  • Open Access

    High-sensitivity detection of Mycobacterium tuberculosis DNA in tongue swab samples

    by Alaina M. Olson, Rachel C. Wood, Kris M. Weigel, Alexander J. Yan, Katherine A. Lochner, Rane B. Dragovich, Angelique K. Luabeya, Paul Yager, Mark Hatherill, Gerard A. Cangelosi

    Tongue swab (TS) sampling combined with qPCR to detect Mycobacterium tuberculosis (MTB) DNA is a promising alternative to sputum testing for tuberculosis (TB) diagnosis. In prior studies, the sensitivity of tongue swabbing has usually been lower than sputum. In this study, we evaluated two strategies to improve sensitivity. In one, centrifugation was used to concentrate tongue dorsum bacteria from 2-mL suspensions eluted from high-capacity foam swab samples. The pellets were resuspended as 500-µL suspensions, and then mechanically lysed prior to dual-target qPCR to detect MTB insertion elements IS 6110 and IS 1081 . Fractionation experiments demonstrated that most of the MTB DNA signal in clinical swab samples (99.22% ± 1.46%) was present in the sedimentable fraction. When applied to archived foam swabs collected from 124 South Africans with presumptive TB, this strategy exhibited 83% sensitivity (71/86) and 100% specificity (38/38) relative to sputum MRS (microbiological reference standard; sputum culture and/or Xpert® Ultra). The second strategy used sequence- specific magnetic capture (SSMaC) to concentrate DNA released from MTB cells. This protocol was evaluated on archived Copan FLOQSwabs® flocked swab samples collected from 128 South African participants with presumptive TB. Material eluted into 500 µL buffer was mechanically lysed. The suspensions were digested by proteinase K, hybridized to biotinylated dual-target oligonucleotide probes, and then concentrated ∼20-fold using magnetic separation. Upon dual-target qPCR testing of concentrates, this strategy exhibited 90% sensitivity (83/92) and 97% specificity (35/36) relative to sputum MRS. These results point the way toward automatable, high-sensitivity methods for detecting MTB DNA in TS. Importance: Improved testing for tuberculosis (TB) is needed. Using a more accessible sample type than sputum may enable the detection of more cases, but it is critical that alternative samples be tested appropriately. Here, we describe two new, highly accurate methods for testing tongue swabs for TB DNA.


  • Two-Fluorophore Mobile Phone Imaging of Biplexed Real-Time NAATs Overcomes Optical Artifacts in Highly Scattering Porous Media

    by Kamal G. Shah, Sujatha Kumar, Vidhi Singh, Louise L Hansen, Erin Heiniger, Joshua Davis Bishop, Barry Lutz, Paul Yager

    Nucleic acid amplification tests (NAATs) are common in laboratory and clinical settings due to their low time to result and exquisite sensitivity and specificity. Laboratory NAATs include onboard positive controls to reduce false negatives and specialized hardware to enable real-time fluorescence detection. Recent efforts to translate NAATs into at-home tests sacrifice one or more of the benefits of laboratory NAATs, such as sensitivity, internal amplification controls (IACs), or time to result. In this manuscript, we describe a mobile-phone-based strategy for real-time imaging of biplexed NAATs in paper. The strategy consisted of 1) using mobile phones with multipass excitation and emission filters on the flash and camera to image the signal from distinct fluorophore-labeled probe types in a duplexed NAAT in a glass fiber membrane; and 2) analyzing the differential fluorescence signal between the red and green color channels of phone images to overcome a strong evaporation-induced optical artifact in heated glass fiber pads due to changes in refractive index. We demonstrated that the differential fluorescence imaging enabled low limits of detection (316 copies of methicillin-resistant Staphylococcus aureus DNA) in our lab’s MD NAAT platform, even in biplexed isothermal strand displacement amplification (iSDA) reactions containing 100k copies of co-amplifying IAC DNA template. These results suggest that two-fluorophore mobile phone imaging may enable translating the benefits of extant laboratory-based, real-time NAATs to the point of care.


  • Disposable Autonomous Device for Swab-to-Result Diagnosis of Influenza

    by Shichu Huang, Koji Abe, Steven Bennett, Tinny Liang, Paula D. Ladd, Lindsay Yokobe, Caitlin E. Anderson, Kamal Shah, Josh Bishop, Mike Purfield, et al.

    A prototype of a self-contained, automated, disposable device for chemically amplified protein-based detection of influenza virus from nasal swab specimens was developed and evaluated in a clinical setting. The device required only simple specimen manipulation without any dedicated instrumentation or specialized training by the operator for interpretation. The device was based on a sandwich immunoassay for influenza virus nucleoprotein; it used an enzyme-labeled antibody and a chromogenic substrate to provide an amplified visible signal, in a two-dimensional paper network format. All reagents were stored within the device. Device performance was assessed at Seattle Children’s Hospital; clinical staff collected nasal swab samples from 25 patients and then operated test devices on site to detect influenza A and B in those specimens. The total test time from device initiation to result was approximately 35 min. Device performance for influenza A detection was ∼70% accurate using in-house qRT-PCR influenza A as a gold-standard comparison. The ratio of valid to total completed device runs yielded a success rate of 92%, and the negative predictive value for both the influenza A and B assay was 81%. The ability to diagnose respiratory infections rapidly and close to the patient was well received by hospital staff, inspiring further optimization of device function.


  • Enabling lateral transport of genomic DNA through porous membranes for point-of-care applications

    by Samantha A. Byrnes, Joshua D. Bishop, Paul Yager

    Simultaneous cell lysis and DNA fragmentation to allow for controllable lateral transport of DNA through commonly-used porous membranes.


  • Open Access

    Single-use paper-based hydrogen fuel cells for point-of-care diagnostic applications

    by J.P. Esquivel, J.R. Buser, C.W. Lim, C. Domínguez, S. Rojas, P. Yager, N. Sabaté


  • One-step purification and concentration of DNA in porous membranes for point-of-care applications

    by S. A. Byrnes, J. D. Bishop, L. Lafleur, J. R. Buser, B. Lutz, P. Yager

    The emergence of rapid, user-friendly, point-of-care (POC) diagnostic systems is paving the way for better disease diagnosis and control. Lately, there has been a strong emphasis on developing molecular-based diagnostics due to their potential for greatly increased sensitivity and specificity. One of the most critical steps in developing practical diagnostic systems is the ability to perform sample preparation, especially the purification of nucleic acids (NA), at the POC. As such, we have developed a simple-to-use, inexpensive, and disposable sample preparation system for in-membrane purification and concentration of NAs. This system couples lateral flow in a porous membrane with chitosan, a linear polysaccharide that captures NAs via anion exchange chromatography. The system can also substantially concentrate the NAs. The combination of these capabilities can be used on a wide range of sample types, which are prepared for use in downstream processes, such as qPCR, without further purification.


  • Open Access

    Development of a paper-based diagnostic for influenza detection

    by Carly A. Holstein, Steven Bennett, Eva-Maria Strauch, Aaron Chevalier, Elain Fu, David Baker, Paul Yager

    The development of novel paper-based diagnostic tests has surged in recent years, due to the suitability of these tests for use at the point of care. These emerging paper-based tests retain the low cost and ease of use of traditional lateral flow tests, while offering increased sophistication and capabilities that approach those of traditional microfluidic devices. Here, we report on the development of a novel paper-based test for the diagnosis of influenza, commonly known as the flu. Influenza is a ubiquitously occurring infection, affecting 5-20% of Americans and resulting in an average of 23,000 deaths in the U.S., and up to 500,000 deaths globally, each year. Despite its prevalence, the diagnosis of influenza remains unsatisfactory, especially at the point of care. In particular, lateral flow tests for influenza suffer from poor sensitivity and provide only limited information about the infecting flu virus. Point-of-care testing of influenza therefore stands to benefit substantially from improved technology. To this end, we have developed two different versions of a paper-based flu assay, both using computationally designed affinity proteins, or “binders,” that bind to the influenza hemagglutinin (HA) protein. One version of the assay utilizes an HA stem-region binder and the other an HA head-region binder. With these assays, we demonstrate the detection of clinically relevant concentrations of recombinant HA and intact influenza virus, as well as the translation of this paper-based system to a two-dimensional paper network (2DPN) folding card device.


  • The evolution of nitrocellulose as a material for bioassays

    by Gina E. Fridley, Carly A. Holstein, Shefali B. Oza, Paul Yager