Surface morphology of osteochondral grafts harvested from femoral condyles with free-hand technique: a cadaveric study
- 25 September 2023
- journal article
- research article
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 34 (2) , 853-862
Abstract
Purpose The purpose of this cadaver study was to examine the surface morphology of the osteochondral grafts harvested from the femoral condyles using the free-hand graft harvesting technique. Materials and methods One hundred osteochondral grafts were harvested with 6.5 mm chisels at ten different donor sites using the free-hand technique in five paired knee specimens (Mean age: 56.4 years). The cartilage and subchondral bone surface angles were measured through multiplanar reconstruction computerized tomography examination. The cartilage thickness was measured with a MicroScribe G2X digitizer with an accuracy of 0.02 mm. An acceptable congruity could be obtained when these plugs were transferred to a perpendicular socket (articular step-off of less than 1 mm and 0.5 mm) was evaluated. Results Four plugs were damaged or broken during harvesting due to technical difficulties; thus remaining 96 plugs were analyzed. The cartilage thickness varied between 1.36 mm and 3.26 mm across the donor sites. The cartilage was the thinnest in the medial intercondylar notch and thickest in the lateral supracondylar notch. Twenty of ninety-six plugs (20.8%) had unacceptable cartilage surface inclination according to the > 0.5 mm protrusion criteria. Of these plugs, 14 were harvested from the lateral intercondylar notch, whereas five of 96 plugs (5.2%) had unacceptable cartilage surface inclination according to the > 1 mm protrusion criteria. Of these plugs, all were harvested from the lateral intercondylar notch. Conclusions High rates of unacceptable plugs (up to 100%) might be harvested from the lateral intercondylar notch. In large chondral lesions that require multiple plugs, lateral and medial supracondylar ridges were the best donor sites for perpendicular plug harvesting, whereas lateral intercondylar notch should be avoided.Keywords
This publication has 28 references indexed in Scilit:
- Image-Guided Techniques Improve the Short-Term Outcome of Autologous Osteochondral Cartilage Repair SurgeriesCARTILAGE, 2013
- Comparison of Mini‐Open Versus Arthroscopic Harvesting of Osteochondral Autografts in the Knee: A Cadaveric StudyArthroscopy, 2012
- Effect of Graft Height Mismatch on Contact Pressures With Osteochondral Grafting of the TalusThe American Journal of Sports Medicine, 2011
- A comparison of open versus arthroscopic harvesting of osteochondral autograftsThe Knee, 2009
- Comparative Study of Navigated versus Freehand Osteochondral Graft Transplantation of the KneeThe American Journal of Sports Medicine, 2009
- Oblique osteochondral plugs transplantation technique for osteochondritis dissecans of the elbow jointKnee Surgery, Sports Traumatology, Arthroscopy, 2008
- A cadaveric analysis of contact stress restoration after osteochondral transplantation of a cylindrical cartilage defectKnee Surgery, Sports Traumatology, Arthroscopy, 2008
- Articular cartilage defects: Study of 25,124 knee arthroscopiesThe Knee, 2007
- The Effect of Angled Osteochondral Grafting on Contact PressureThe American Journal of Sports Medicine, 2006
- Arthroscopic autogenous osteochondral mosaicplasty for the treatment of femoral condylar articular defectsKnee Surgery, Sports Traumatology, Arthroscopy, 1997