Ersin Tasatan
Ersin Tasatan has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Ozkan Kose
Antalya Eğitim ve Araştırma Hastanesi
6 shared publications - Albert Cakar
Department of Orthopedics and Traumatology, Istanbul Training and Research Hospital, Istanbul, Turkey
5 shared publications - Bulent Karslioglu
Hakkari Military Hospital Hakkari, Turkey
4 shared publications - Hakan Gürbüz
Department of Orthopedic and Traumatology, Prof. Dr. Cemil Taşcıoğlu City Hospital, Istanbul, Turkey
4 shared publications - Ali Çağrı Tekin
Department of Orthopedics and Traumatology, Prof. Dr. Cemil Taşçıoğlu City Hospital, İstanbul, Türkiye
3 shared publications - Esra Akdaş Tekin
Department of Anesthesiology and Reanimation, Prof. Dr. Cemil Taşcıoğlu City Hospital, Istanbul, Türkiye
3 shared publications
Latest Publications
- Open Access
- 20 April 2026
- Published by MDPI AG in Healthcare
- Vol. 14 (8) , 1095
Profiling Culturally Responsive Care: Intercultural Communication and Empathy in the Nursing Workforce
Background/Objectives: Culturally responsive care requires both intercultural communication competence (ICC) and empathy; however, these constructs are often examined separately in nursing research. This study aimed to (i) describe nurses’ ICC and empathy levels, (ii) test the association between ICC and empathy, and (iii) examine group differences by selected demographic and professional variables. Methods: A quantitative, cross-sectional correlational design was conducted with 300 nurses recruited from state and private hospitals. ICC was measured using the Arasaratnam Intercultural Communication Competence Scale (cognitive, affective, and total), and empathy was assessed using the 18-item Jefferson Scale of Empathy (compassionate care, perspective taking, standing in the patient’s shoes, and total). Data were analyzed with descriptive statistics, Pearson correlations, independent-samples t-tests, and one-way ANOVAs with Scheffé post hoc tests (α = 0.05). Results: Both ICC and empathy were above the scale midpoint. Cognitive ICC (M = 4.71, SD = 1.42) exceeded affective ICC (M = 4.35, SD = 1.34), and total empathy was high (M = 4.50, SD = 0.90), with compassionate care as the highest subscale (M = 4.60, SD = 1.10). ICC total was moderately correlated with total empathy (r = 0.607, p < 0.05); affective ICC correlated with compassionate care (r = 0.455) and perspective taking (r = 0.493). Male nurses reported higher ICC than female nurses (p < 0.05), while empathy did not differ by gender. Younger nurses (20–29) scored higher in ICC and empathy than older groups, and nurses with ≥28 years of experience also showed elevated levels. Nurses who willingly chose nursing had higher ICC and empathy across dimensions (all p < 0.001). Hospital type showed minimal differences except for “standing in the patient’s shoes” (private > state, p = 0.04). Conclusions: ICC and empathy were generally high and interrelated among nurses, with meaningful variation across workforce characteristics. Training should emphasize experiential and reflective approaches to strengthen affective ICC and perspective taking, while organizational strategies should foster intrinsic motivation and support professional development across career stages.
- 20 April 2026
- Published by MDPI AG in Healthcare
- Vol. 14 (8) , 1095
Open AccessProfiling Culturally Responsive Care: Intercultural Communication and Empathy in the Nursing Workforce
Background/Objectives: Culturally responsive care requires both intercultural communication competence (ICC) and empathy; however, these constructs are often examined separately in nursing research. This study aimed to (i) describe nurses’ ICC and empathy levels, (ii) test the association between ICC and empathy, and (iii) examine group differences by selected demographic and professional variables. Methods: A quantitative, cross-sectional correlational design was conducted with 300 nurses recruited from state and private hospitals. ICC was measured using the Arasaratnam Intercultural Communication Competence Scale (cognitive, affective, and total), and empathy was assessed using the 18-item Jefferson Scale of Empathy (compassionate care, perspective taking, standing in the patient’s shoes, and total). Data were analyzed with descriptive statistics, Pearson correlations, independent-samples t-tests, and one-way ANOVAs with Scheffé post hoc tests (α = 0.05). Results: Both ICC and empathy were above the scale midpoint. Cognitive ICC (M = 4.71, SD = 1.42) exceeded affective ICC (M = 4.35, SD = 1.34), and total empathy was high (M = 4.50, SD = 0.90), with compassionate care as the highest subscale (M = 4.60, SD = 1.10). ICC total was moderately correlated with total empathy (r = 0.607, p < 0.05); affective ICC correlated with compassionate care (r = 0.455) and perspective taking (r = 0.493). Male nurses reported higher ICC than female nurses (p < 0.05), while empathy did not differ by gender. Younger nurses (20–29) scored higher in ICC and empathy than older groups, and nurses with ≥28 years of experience also showed elevated levels. Nurses who willingly chose nursing had higher ICC and empathy across dimensions (all p < 0.001). Hospital type showed minimal differences except for “standing in the patient’s shoes” (private > state, p = 0.04). Conclusions: ICC and empathy were generally high and interrelated among nurses, with meaningful variation across workforce characteristics. Training should emphasize experiential and reflective approaches to strengthen affective ICC and perspective taking, while organizational strategies should foster intrinsic motivation and support professional development across career stages.
- 25 September 2023
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 34 (2) , 853-862
Surface morphology of osteochondral grafts harvested from femoral condyles with free-hand technique: a cadaveric study
Purpose The purpose of this cadaver study was to examine the surface morphology of the osteochondral grafts harvested from the femoral condyles using the free-hand graft harvesting technique. Materials and methods One hundred osteochondral grafts were harvested with 6.5 mm chisels at ten different donor sites using the free-hand technique in five paired knee specimens (Mean age: 56.4 years). The cartilage and subchondral bone surface angles were measured through multiplanar reconstruction computerized tomography examination. The cartilage thickness was measured with a MicroScribe G2X digitizer with an accuracy of 0.02 mm. An acceptable congruity could be obtained when these plugs were transferred to a perpendicular socket (articular step-off of less than 1 mm and 0.5 mm) was evaluated. Results Four plugs were damaged or broken during harvesting due to technical difficulties; thus remaining 96 plugs were analyzed. The cartilage thickness varied between 1.36 mm and 3.26 mm across the donor sites. The cartilage was the thinnest in the medial intercondylar notch and thickest in the lateral supracondylar notch. Twenty of ninety-six plugs (20.8%) had unacceptable cartilage surface inclination according to the > 0.5 mm protrusion criteria. Of these plugs, 14 were harvested from the lateral intercondylar notch, whereas five of 96 plugs (5.2%) had unacceptable cartilage surface inclination according to the > 1 mm protrusion criteria. Of these plugs, all were harvested from the lateral intercondylar notch. Conclusions High rates of unacceptable plugs (up to 100%) might be harvested from the lateral intercondylar notch. In large chondral lesions that require multiple plugs, lateral and medial supracondylar ridges were the best donor sites for perpendicular plug harvesting, whereas lateral intercondylar notch should be avoided.
- 25 September 2023
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 34 (2) , 853-862
Surface morphology of osteochondral grafts harvested from femoral condyles with free-hand technique: a cadaveric study
Purpose The purpose of this cadaver study was to examine the surface morphology of the osteochondral grafts harvested from the femoral condyles using the free-hand graft harvesting technique. Materials and methods One hundred osteochondral grafts were harvested with 6.5 mm chisels at ten different donor sites using the free-hand technique in five paired knee specimens (Mean age: 56.4 years). The cartilage and subchondral bone surface angles were measured through multiplanar reconstruction computerized tomography examination. The cartilage thickness was measured with a MicroScribe G2X digitizer with an accuracy of 0.02 mm. An acceptable congruity could be obtained when these plugs were transferred to a perpendicular socket (articular step-off of less than 1 mm and 0.5 mm) was evaluated. Results Four plugs were damaged or broken during harvesting due to technical difficulties; thus remaining 96 plugs were analyzed. The cartilage thickness varied between 1.36 mm and 3.26 mm across the donor sites. The cartilage was the thinnest in the medial intercondylar notch and thickest in the lateral supracondylar notch. Twenty of ninety-six plugs (20.8%) had unacceptable cartilage surface inclination according to the > 0.5 mm protrusion criteria. Of these plugs, 14 were harvested from the lateral intercondylar notch, whereas five of 96 plugs (5.2%) had unacceptable cartilage surface inclination according to the > 1 mm protrusion criteria. Of these plugs, all were harvested from the lateral intercondylar notch. Conclusions High rates of unacceptable plugs (up to 100%) might be harvested from the lateral intercondylar notch. In large chondral lesions that require multiple plugs, lateral and medial supracondylar ridges were the best donor sites for perpendicular plug harvesting, whereas lateral intercondylar notch should be avoided.
- 15 July 2023
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 143 (11) , 6675-6684
Complications of peroneus longus tendon harvesting: a retrospective review of 82 cases
Objective Peroneus longus tendon (PLT) has become a reliable autologous graft option for various ligament reconstructions. But there are potential risks and complications associated with its use as a graft. This retrospective study aimed to examine the complications and donor site morbidity following PLT harvesting. Patients and methods A retrospective review was performed on an institutional digital patient database, and all patients who underwent ligament reconstruction using PLT autograft were identified. Intraoperative, early, and late complications were reviewed using digital patient notes and patients underwent a complete physical examination during their final follow-up. Ankle function was assessed using the AOFAS score, and manual ankle muscle testing was performed on both sides. Sural nerve iatrogenic injury was evaluated with a dermatomal light touch examination. Cosmetic satisfaction due to incision scar and footwear complaints were also assessed. Results 82 patients (74 male, eight female) with a mean age of 31.9 ± 10.4 years (range, 16–66) were included in the final analysis. The mean follow-up time was 46.6 ± 30.3 months (range, 6–109). The mean AOFAS score for the donor side was 98.7 ± 3.3 (range, 87–100), and the contralateral side score was 100, with manual muscle testing graded as 5 in all movements and similar to the contralateral side. Fifteen patients (18.3%) had hypoesthesia over the dorsolateral aspect of the foot distal to the incision scar, two patients (2.4%) had hyperalgesia over the distal incision scar, and one patient (1.2%) had mild ankle instability. There were two cases (2.4%) of compartment syndrome, both of which were treated with fasciotomy and had complete regression of symptoms after 5 days. One patient (1.2%) had a transient peroneal nerve injury and foot drop that resolved in the sixth month. Conclusions The results of this retrospective study suggest that harvesting the PLT is associated with a high rate of complications and donor site morbidity. The most common complication was hypoesthesia around the lateral side of the foot, although the ankle functions were not affected significantly. Two cases of compartment syndrome and one transient peroneal nerve injury were observed. Care should be taken while harvesting PLT autograft, and it should be kept in mind that peroneal nerve injury might occur. Level of evidence Level IV, retrospective case series.
- 15 July 2023
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 143 (11) , 6675-6684
Complications of peroneus longus tendon harvesting: a retrospective review of 82 cases
Objective Peroneus longus tendon (PLT) has become a reliable autologous graft option for various ligament reconstructions. But there are potential risks and complications associated with its use as a graft. This retrospective study aimed to examine the complications and donor site morbidity following PLT harvesting. Patients and methods A retrospective review was performed on an institutional digital patient database, and all patients who underwent ligament reconstruction using PLT autograft were identified. Intraoperative, early, and late complications were reviewed using digital patient notes and patients underwent a complete physical examination during their final follow-up. Ankle function was assessed using the AOFAS score, and manual ankle muscle testing was performed on both sides. Sural nerve iatrogenic injury was evaluated with a dermatomal light touch examination. Cosmetic satisfaction due to incision scar and footwear complaints were also assessed. Results 82 patients (74 male, eight female) with a mean age of 31.9 ± 10.4 years (range, 16–66) were included in the final analysis. The mean follow-up time was 46.6 ± 30.3 months (range, 6–109). The mean AOFAS score for the donor side was 98.7 ± 3.3 (range, 87–100), and the contralateral side score was 100, with manual muscle testing graded as 5 in all movements and similar to the contralateral side. Fifteen patients (18.3%) had hypoesthesia over the dorsolateral aspect of the foot distal to the incision scar, two patients (2.4%) had hyperalgesia over the distal incision scar, and one patient (1.2%) had mild ankle instability. There were two cases (2.4%) of compartment syndrome, both of which were treated with fasciotomy and had complete regression of symptoms after 5 days. One patient (1.2%) had a transient peroneal nerve injury and foot drop that resolved in the sixth month. Conclusions The results of this retrospective study suggest that harvesting the PLT is associated with a high rate of complications and donor site morbidity. The most common complication was hypoesthesia around the lateral side of the foot, although the ankle functions were not affected significantly. Two cases of compartment syndrome and one transient peroneal nerve injury were observed. Care should be taken while harvesting PLT autograft, and it should be kept in mind that peroneal nerve injury might occur. Level of evidence Level IV, retrospective case series.
- Open Access
- 26 June 2023
- Published by Springer Nature in Journal of Orthopaedics and Traumatology
- Vol. 24 (1) , 1-13
Comparison of four different screw configurations for the fixation of Fulkerson osteotomy: a finite element analysis
Background: Conventionally, two 4.5 mm cortical screws inserted toward the posterior tibial cortex are usually advocated for the fixation of Fulkerson osteotomy. This finite element analysis aimed to compare the biomechanical behavior of four different screw configurations to fix the Fulkerson osteotomy. Materials and methods: Fulkerson osteotomy was modeled using computerized tomography (CT) data of a patient with patellofemoral instability and fixed with four different screw configurations using two 4.5 mm cortical screws in the axial plane. The configurations were as follows: (1) two screws perpendicular to the osteotomy plane, (2) two screws perpendicular to the posterior cortex of the tibia, (3) the upper screw perpendicular to the osteotomy plane, but the lower screw is perpendicular to the posterior cortex of the tibia, and (4) the reverse position of the screw configuration in the third scenario. Gap formation, sliding, displacement, frictional stress, and deformation of the components were calculated and reported. Results: The osteotomy fragment moved superiorly after loading the models with 1654 N patellar tendon traction force. Since the proximal cut is sloped (bevel-cut osteotomy), the osteotomy fragment slid and rested on the upper tibial surface. Afterward, the upper surface of the osteotomy fragment acted as a fulcrum, and the distal part of the fragment began to separate from the tibia while the screws resisted the displacement. The resultant total displacement was 0.319 mm, 0.307 mm, 0.333 mm, and 0.245 mm from the first scenario to the fourth scenario, respectively. The minimum displacement was detected in the fourth scenario (upper screw perpendicular to the osteotomy plane and lower screw perpendicular to the posterior tibial cortex). Maximum frictional stress and maximum pressure between components on both surfaces were highest in the first scenario (both screws perpendicular to the osteotomy plane). Conclusions: A divergent screw configuration in which the upper screw is inserted perpendicular to the osteotomy plane and the lower screw is inserted perpendicular to the posterior tibial cortex might be a better option for the fixation of Fulkerson osteotomy. Level of evidence Level V, mechanism-based reasoning.
- 26 June 2023
- Published by Springer Nature in Journal of Orthopaedics and Traumatology
- Vol. 24 (1) , 1-13
Open AccessComparison of four different screw configurations for the fixation of Fulkerson osteotomy: a finite element analysis
Background: Conventionally, two 4.5 mm cortical screws inserted toward the posterior tibial cortex are usually advocated for the fixation of Fulkerson osteotomy. This finite element analysis aimed to compare the biomechanical behavior of four different screw configurations to fix the Fulkerson osteotomy. Materials and methods: Fulkerson osteotomy was modeled using computerized tomography (CT) data of a patient with patellofemoral instability and fixed with four different screw configurations using two 4.5 mm cortical screws in the axial plane. The configurations were as follows: (1) two screws perpendicular to the osteotomy plane, (2) two screws perpendicular to the posterior cortex of the tibia, (3) the upper screw perpendicular to the osteotomy plane, but the lower screw is perpendicular to the posterior cortex of the tibia, and (4) the reverse position of the screw configuration in the third scenario. Gap formation, sliding, displacement, frictional stress, and deformation of the components were calculated and reported. Results: The osteotomy fragment moved superiorly after loading the models with 1654 N patellar tendon traction force. Since the proximal cut is sloped (bevel-cut osteotomy), the osteotomy fragment slid and rested on the upper tibial surface. Afterward, the upper surface of the osteotomy fragment acted as a fulcrum, and the distal part of the fragment began to separate from the tibia while the screws resisted the displacement. The resultant total displacement was 0.319 mm, 0.307 mm, 0.333 mm, and 0.245 mm from the first scenario to the fourth scenario, respectively. The minimum displacement was detected in the fourth scenario (upper screw perpendicular to the osteotomy plane and lower screw perpendicular to the posterior tibial cortex). Maximum frictional stress and maximum pressure between components on both surfaces were highest in the first scenario (both screws perpendicular to the osteotomy plane). Conclusions: A divergent screw configuration in which the upper screw is inserted perpendicular to the osteotomy plane and the lower screw is inserted perpendicular to the posterior tibial cortex might be a better option for the fixation of Fulkerson osteotomy. Level of evidence Level V, mechanism-based reasoning.
- 8 June 2023
- Published by Galenos Yayinevi in Gulhane Medical Journal
- Vol. 65 (2) , 72-78
Adult proximal humerus locking plate for fixation of paediatric intertrochanteric femoral fractures
- 8 June 2023
- Published by Galenos Yayinevi in Gulhane Medical Journal
- Vol. 65 (2) , 72-78
Adult proximal humerus locking plate for fixation of paediatric intertrochanteric femoral fractures
- 15 April 2023
- Published by Elsevier in Fuß & Sprunggelenk
- Vol. 21 (4) , 323-332
The relationship between hallux valgus and the first metatarsal length; a case-control study
- 15 April 2023
- Published by Elsevier in Fuß & Sprunggelenk
- Vol. 21 (4) , 323-332
The relationship between hallux valgus and the first metatarsal length; a case-control study
- 30 March 2023
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 57 (6) , 838-846
Is the Akagi Line a Reliable Landmark for Adjusting the Rotational Axis of the Tibial Component in Patients with Patellofemoral Instability?
Purpose This study aimed to investigate whether the Akagi line is a reliable anatomic landmark for adjusting the rotational axis of the tibial component in patients with patellofemoral (PF) malalignment. Materials and methods This retrospective case–control study included 86 patients with PF instability and 129 controls. On the superimposed axial CT images, TT-TG, TT-PCL, nTT-TG, nTT-PCL, knee joint rotation, and the angle between the Akagi line and surgical transepicondylar axis (Akagi/sTEA angle) were measured. In addition, a modified Akagi line, drawn 1 cm medial to the patellar tendon attachment, was defined, and the angle between the new Akagi line and sTEA (mAkagi/sTEA angle) was also measured and compared between groups. Results There were 86 patients (47 females, 39 males) in the case group and 129 patients (56 females, 73 males) in the control group with a mean age of 35.7 ± 17.9 years and 41.1 ± 18.8 years, respectively (p < 0.001). Radiologic variables of PF alignment (TT-TG, TT-PCL, nTT-TG, nTT-PCL, and knee joint rotation) were significantly abnormal in the case group (p < 0.001 for all variables). The Akagi/sTEA angle was significantly higher in the case group, resulting in 89.5% external malrotation of the tibial component (> 10°). However, the tibial component was 96.5% aligned correctly (between 10° external and 3° internal rotation) in the control group. Using the modified Akagi line significantly improved the rotational alignment, and normal tibial rotation increased to 93.3% of the case group. The Akagi/sTEA angle strongly correlated with the knee rotation (rho: 0.735, p: 0.001), TT-TG (rho: 0.715, p: 0.001) and nTT-TG (rho: 0.783, p: 0.001). But the TT-PCL (rho: 0.459, p: 0.001) and nTT-PCL (rho: 0.589, p: 0.001) had a medium correlation. Conclusions The Akagi line might cause unacceptable external rotation of the tibial component in patients with PF malalignment. The use of the modified Akagi line described in this study may be a solution for the rotational mismatch between femoral and tibial components in TKA. Level of evidence Level III, retrospective case–control study.
- 30 March 2023
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 57 (6) , 838-846
Is the Akagi Line a Reliable Landmark for Adjusting the Rotational Axis of the Tibial Component in Patients with Patellofemoral Instability?
Purpose This study aimed to investigate whether the Akagi line is a reliable anatomic landmark for adjusting the rotational axis of the tibial component in patients with patellofemoral (PF) malalignment. Materials and methods This retrospective case–control study included 86 patients with PF instability and 129 controls. On the superimposed axial CT images, TT-TG, TT-PCL, nTT-TG, nTT-PCL, knee joint rotation, and the angle between the Akagi line and surgical transepicondylar axis (Akagi/sTEA angle) were measured. In addition, a modified Akagi line, drawn 1 cm medial to the patellar tendon attachment, was defined, and the angle between the new Akagi line and sTEA (mAkagi/sTEA angle) was also measured and compared between groups. Results There were 86 patients (47 females, 39 males) in the case group and 129 patients (56 females, 73 males) in the control group with a mean age of 35.7 ± 17.9 years and 41.1 ± 18.8 years, respectively (p < 0.001). Radiologic variables of PF alignment (TT-TG, TT-PCL, nTT-TG, nTT-PCL, and knee joint rotation) were significantly abnormal in the case group (p < 0.001 for all variables). The Akagi/sTEA angle was significantly higher in the case group, resulting in 89.5% external malrotation of the tibial component (> 10°). However, the tibial component was 96.5% aligned correctly (between 10° external and 3° internal rotation) in the control group. Using the modified Akagi line significantly improved the rotational alignment, and normal tibial rotation increased to 93.3% of the case group. The Akagi/sTEA angle strongly correlated with the knee rotation (rho: 0.735, p: 0.001), TT-TG (rho: 0.715, p: 0.001) and nTT-TG (rho: 0.783, p: 0.001). But the TT-PCL (rho: 0.459, p: 0.001) and nTT-PCL (rho: 0.589, p: 0.001) had a medium correlation. Conclusions The Akagi line might cause unacceptable external rotation of the tibial component in patients with PF malalignment. The use of the modified Akagi line described in this study may be a solution for the rotational mismatch between femoral and tibial components in TKA. Level of evidence Level III, retrospective case–control study.
- 1 January 2023
- Published by Kare Publishing in Eurasian Journal of Medical Investigation
- Vol. 7 (1) , 69-73
Proximal Femoral Nailing Fixation of Femoral Intertrochanteric Fractures in Parkinson's Disease
Ejmi Eurasian Journal of Medical Investigation
- 1 January 2023
- Published by Kare Publishing in Eurasian Journal of Medical Investigation
- Vol. 7 (1) , 69-73
Proximal Femoral Nailing Fixation of Femoral Intertrochanteric Fractures in Parkinson's Disease
Ejmi Eurasian Journal of Medical Investigation
- 29 September 2022
- Published by Kare Publishing in European Archives of Medical Research
- Vol. 38 (3) , 161-165
Early and Mid-term Results Following Surgery of Elbow Fractures with the Terrible Triad
- 29 September 2022
- Published by Kare Publishing in European Archives of Medical Research
- Vol. 38 (3) , 161-165
Early and Mid-term Results Following Surgery of Elbow Fractures with the Terrible Triad
- 26 August 2022
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 143 (6) , 3309-3317
Comparison of three methods for sealing of the intramedullary femoral canal during total knee arthroplasty; a randomized controlled trial
Purpose The purpose of this randomized controlled study was to examine the effect of sealing the intramedullary canal with a bone or cement plug or leaving it empty on postoperative bleeding and pain Materials and methods A total of 120 patients with knee osteoarthritis who underwent unilateral TKA participated in the trial and were assigned to one of three groups. The femoral canal was sealed with an autogenous bone plug (Group I) or cement plug (Group II), or it was left open (Group III). Estimated blood loss, Hemoglobin decline, bleeding into the drain, and postoperative pain w compared between groups. Results Six patients were excluded due to various reasons, and the remaining 114 patients were included in the final analysis. There were no significant variations in baseline clinical characteristics between the three groups (p > 0.05). Hemoglobin reduction between preoperative and 72 h after the surgery (p: 0.034) and estimated blood loss (p: 0.003) were significantly different between groups. The cement plug group showed the least bleeding. Although there was a significant difference between the cement and empty canal groups (p: 0.03 and p: 0.002, respectively), the difference between the cement and bone groups was similar regarding both hemoglobin reduction and estimated blood loss. The blood volume in the suction drain (p: 0.598) and transfusion rate (p: 0.087) were similar between the groups. VAS at the 12 h after the surgery was similarly high in each group (p: 0.676). It declined at 36 h after surgery, but no significant difference was determined between groups (p: 0.815). Conclusions This study showed that estimated blood loss and hemoglobin reduction were significantly lower in the cement plug group than in the empty canal group. But bone plug group did not show any difference with both empty canal and cement plug groups. Sealing the IM canal or leaving it open did not change the bleeding into the drain, transfusion rate, and postoperative pain between groups. Based on these findings, sealing the IM canal with a cement plug might be recommended to diminish bleeding during TKA despite similar transfusion rates. Level of evidence Level I, randomized controlled trial.
- 26 August 2022
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 143 (6) , 3309-3317
Comparison of three methods for sealing of the intramedullary femoral canal during total knee arthroplasty; a randomized controlled trial
Purpose The purpose of this randomized controlled study was to examine the effect of sealing the intramedullary canal with a bone or cement plug or leaving it empty on postoperative bleeding and pain Materials and methods A total of 120 patients with knee osteoarthritis who underwent unilateral TKA participated in the trial and were assigned to one of three groups. The femoral canal was sealed with an autogenous bone plug (Group I) or cement plug (Group II), or it was left open (Group III). Estimated blood loss, Hemoglobin decline, bleeding into the drain, and postoperative pain w compared between groups. Results Six patients were excluded due to various reasons, and the remaining 114 patients were included in the final analysis. There were no significant variations in baseline clinical characteristics between the three groups (p > 0.05). Hemoglobin reduction between preoperative and 72 h after the surgery (p: 0.034) and estimated blood loss (p: 0.003) were significantly different between groups. The cement plug group showed the least bleeding. Although there was a significant difference between the cement and empty canal groups (p: 0.03 and p: 0.002, respectively), the difference between the cement and bone groups was similar regarding both hemoglobin reduction and estimated blood loss. The blood volume in the suction drain (p: 0.598) and transfusion rate (p: 0.087) were similar between the groups. VAS at the 12 h after the surgery was similarly high in each group (p: 0.676). It declined at 36 h after surgery, but no significant difference was determined between groups (p: 0.815). Conclusions This study showed that estimated blood loss and hemoglobin reduction were significantly lower in the cement plug group than in the empty canal group. But bone plug group did not show any difference with both empty canal and cement plug groups. Sealing the IM canal or leaving it open did not change the bleeding into the drain, transfusion rate, and postoperative pain between groups. Based on these findings, sealing the IM canal with a cement plug might be recommended to diminish bleeding during TKA despite similar transfusion rates. Level of evidence Level I, randomized controlled trial.