Embedded Ultrathin Cluster Electrodes for Long-Term Recordings in Deep Brain Centers
Open Access
- 9 May 2016
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (5) , e0155109
Abstract
Neural interfaces which allow long-term recordings in deep brain structures in awake freely moving animals have the potential of becoming highly valuable tools in neuroscience. However, the recording quality usually deteriorates over time, probably at least partly due to tissue reactions caused by injuries during implantation, and subsequently micro-forces due to a lack of mechanical compliance between the tissue and neural interface. To address this challenge, we developed a gelatin embedded neural interface comprising highly flexible electrodes and evaluated its long term recording properties. Bundles of ultrathin parylene C coated platinum electrodes (N = 29) were embedded in a hard gelatin based matrix shaped like a needle, and coated with Kollicoat™ to retard dissolution of gelatin during the implantation. The implantation parameters were established in an in vitro model of the brain (0.5% agarose). Following a craniotomy in the anesthetized rat, the gelatin embedded electrodes were stereotactically inserted to a pre-target position, and after gelatin dissolution the electrodes were further advanced and spread out in the area of the subthalamic nucleus (STN). The performance of the implanted electrodes was evaluated under anesthesia, during 8 weeks. Apart from an increase in the median-noise level during the first 4 weeks, the electrode impedance and signal-to-noise ratio of single-units remained stable throughout the experiment. Histological postmortem analysis confirmed implantation in the area of STN in most animals. In conclusion, by combining novel biocompatible implantation techniques and ultra-flexible electrodes, long-term neuronal recordings from deep brain structures with no significant deterioration of electrode function were achieved.Keywords
This publication has 73 references indexed in Scilit:
- The density difference between tissue and neural probes is a key factor for glial scarringScientific Reports, 2013
- Comprehensive Analysis of Tissue Preservation and Recording Quality from Chronic Multielectrode ImplantsPLOS ONE, 2011
- Implant Size and Fixation Mode Strongly Influence Tissue Reactions in the CNSPLOS ONE, 2011
- Bridging the divide between neuroprosthetic design, tissue engineering and neurobiologyFrontiers in Neuroengineering, 2010
- Improving impedance of implantable microwire multi-electrode arrays by ultrasonic electroplating of durable platinum blackFrontiers in Neuroengineering, 2010
- Insertion shuttle with carboxyl terminated self-assembled monolayer coatings for implanting flexible polymer neural probes in the brainJournal of Neuroscience Methods, 2009
- Technology Insight: neuroengineering and epilepsy—designing devices for seizure controlNature Clinical Practice Neurology, 2008
- Deep Brain Stimulation for EpilepsyNeurotherapeutics, 2008
- The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skullJournal of Biomedical Materials Research Part A, 2007
- Implantable microscale neural interfacesBiomedical Microdevices, 2007