Dosimetric uncertainty in prostate cancer proton radiotherapy
- 13 October 2008
- journal article
- radiation therapy-physics
- Published by Wiley in Medical Physics
- Vol. 35 (11) , 4800-4807
Abstract
Purpose: The authors we evaluate the uncertainty in proton therapy dose distribution for prostate cancer due to organ displacement, varying penumbra width of proton beams, and the amount of rectal gas inside the rectum. Methods and Materials: Proton beam treatment plans were generated for ten prostate patients with a minimum dose of 74.1 cobalt gray equivalent (CGE) to the planning target volume (PTV) while 95% of the PTV received 78 CGE. Two lateral or lateral oblique proton beams were used for each plan. The authors we investigated the uncertainty in dose to the rectal wall (RW) and the bladder wall (BW) due to organ displacement by comparing the dose‐volume histograms (DVH) calculated with the original or shifted contours. The variation between DVHs was also evaluated for patients with and without rectal gas in the rectum for five patients who had of visible rectal gas in their planning computed tomography (CT) imaging set. The uncertainty due to the varying penumbra width of the delivered protons for different beam setting options on the proton delivery system was also evaluated. Results: For a anterior shift, the relative change in the RW volume receiving 70 CGE dose was 37.9% (5.0% absolute change in 13.2% of a mean ). The relative change in the BW volume receiving 70 CGE dose was 20.9% (4.3% absolute change in 20.6% of a mean ) with a inferior shift. A penumbra difference in beam setting options on the proton delivery system resulted in the relative variations of 6.1% (0.8% absolute change) and 4.4% (0.9% absolute change) in of RW and BW, respectively. The data show that the organ displacements produce absolute DVH changes that generally shift the entire isodose line while maintaining the same shape. The overall shape of the DVH curve for each organ is determined by the penumbra and the distance of the target in beam's eye view (BEV) from the block edge. The beam setting option producing a sharper penumbra at the isocenter can reduce the magnitude of maximal doses to the RW by 2% compared to the alternate option utilizing the same block margin of . The dose to of the femoral head on the distal side of the lateral‐posterior oblique beam is increased by 25 CGE for a patient with of rectal gas. Conclusion: Variation in the rectal and bladder wall DVHs due to uncertainty in the position of the organs relative to the location of sharp dose falloff gradients should be accounted for when evaluating treatment plans. The proton beam delivery option producing a sharper penumbra reduces maximal doses to the rectal wall. Lateral‐posterior oblique beams should be avoided in patients prone to develop a large amount of rectal gas.Keywords
This publication has 26 references indexed in Scilit:
- Proton Therapy Coverage for Prostate Cancer TreatmentInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- Patient-Assessed Late Toxicity Rates and Principal Component Analysis After Image-Guided Radiation Therapy for Prostate CancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Accounting for range uncertainties in the optimization of intensity modulated proton therapyPhysics in Medicine & Biology, 2007
- Investigation of bladder dose and volume factors influencing late urinary toxicity after external beam radiotherapy for prostate cancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Incidence of late rectal bleeding in high-dose conformal radiotherapy of prostate cancer using equivalent uniform dose–based and dose–volume–based normal tissue complication probability modelsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Multi-institutional clinical experience with the Calypso System in localization and continuous, real-time monitoring of the prostate gland during external radiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Effect of anatomic motion on proton therapy dose distributions in prostate cancer treatmentInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Long-Term Outcome of High Dose Intensity Modulated Radiation Therapy for Patients With Clinically Localized Prostate CancerJournal of Urology, 2006
- A pencil beam algorithm for proton dose calculationsPhysics in Medicine & Biology, 1996
- Compensating for heterogeneities in proton radiation therapyPhysics in Medicine & Biology, 1984