WHWen C. Hsi

Wen C. Hsi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Wen C. Hsi has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • In vivo verification of proton beam path by using post‐treatment PET/CT imaging

    by Wen C. Hsi, Daniel J. Indelicato, Carlos Vargas, Srividya Duvvuri, Zuofeng Li, Jatinder Palta

    Purpose: The purpose of this study is to establish the in vivo verification of proton beam path by using proton‐activated positron emission distributions.Methods: A total of 50 PET/CT imaging studies were performed on ten prostate cancer patients immediately after daily proton therapy treatment through a single lateral portal. The PET/CT and planning CT were registered by matching the pelvic bones, and the beam path of delivered protons was defined in vivo by the positron emission distribution seen only within the pelvic bones, referred to as the PET‐defined beam path. Because of the patient position correction at each fraction, the marker‐defined beam path, determined by the centroid of implanted markers seen in the post‐treatment (post‐Tx) CT, is used for the planned beam path. The angular variation and discordance between the PET‐ and marker‐defined paths were derived to investigate the intrafraction prostate motion. For studies with large discordance, the relative location between the centroid and pelvic bones seen in the post‐Tx CT was examined. The PET/CT studies are categorized for distinguishing the prostate motion that occurred before or after beam delivery. The post‐PET CT was acquired after PET imaging to investigate prostate motion due to physiological changes during the extended PET acquisition.Results: The less than 2° of angular variation indicates that the patient roll was minimal within the immobilization device. Thirty of the 50 studies with small discordance, referred as good cases, show a consistent alignment between the field edges and the positron emission distributions from the entrance to the distal edge. For those good cases, average displacements are 0.6 and 1.3 mm along the anterior‐posterior and superior‐inferior directions, respectively, with 1.6 mm standard deviations in both directions. For the remaining 20 studies demonstrating a large discordance (more than 6 mm in either or ), 13 studies, referred as motion‐after‐Tx cases, also show large misalignment between the field edge and the positron emission distribution in lipomatous tissues around the prostate. These motion‐after‐Tx cases correspond to patients with large changes in volume of rectal gas between the post‐Tx and the post‐PET CTs. The standard deviations for and are 5.0 and 3.0 mm, respectively, for these motion‐after‐Tx cases. The final seven studies, referred to as position‐error cases, which had a large discordance but no misalignment, were found to have deviations of 4.6 and 3.6 mm in and , respectively. The position‐error cases correspond to a large discrepancy on the relative location between the centroid and pelvic bones seen in post‐Tx CT and recorded x‐ray radiographs.Conclusions: Systematic analyses of proton‐activated positron emission distributions provide patient‐specific information on prostate motion () and patient position variability () during daily proton beam delivery. The less than 2 mm of displacement variations in the good cases indicates that population‐based values of and used in margin algorithms for treatment planning at the authors’ institution are valid for the majority of cases. However, a small fraction of PET/CT studies (approximately 14%) with displacement variations may require different margins. Such data are useful in establishing patient‐specific planning target volume margins.


  • Energy spectrum control for modulated proton beams

    by Wen C. Hsi, Michael F. Moyers, Dmitri Nichiporov, Vladimir Anferov, Mark Wolanski, Chris E. Allgower, Jonathan B. Farr, Anthony E. Mascia, Andries N. Schreuder

    In proton therapy delivered with range modulated beams, the energy spectrum of protons entering the delivery nozzle can affect the dose uniformity within the target region and the dose gradient around its periphery. For a cyclotron with a fixed extraction energy, a rangeshifter is used to change the energy but this produces increasing energy spreads for decreasing energies. This study investigated the magnitude of the effects of different energy spreads on dose uniformity and distal edge dose gradient and determined the limits for controlling the incident spectrum. A multilayer Faraday cup (MLFC) was calibrated against depth dose curves measured in water for nonmodulated beams with various incident spectra. Depth dose curves were measured in a water phantom and in a multilayer ionization chamber detector for modulated beams using different incident energy spreads. Some nozzle entrance energy spectra can produce unacceptable dose nonuniformities of up to over the modulated region. For modulated beams and small beam ranges, the width of the distal penumbra can vary by a factor of 2.5. When the energy spread was controlled within the defined limits, the dose nonuniformity was less than . To facilitate understanding of the results, the data were compared to the measured and Monte Carlo calculated data from a variable extraction energy synchrotron which has a narrow spectrum for all energies. Dose uniformity is only maintained within prescription limits when the energy spread is controlled. At low energies, a large spread can be beneficial for extending the energy range at which a single range modulator device can be used. An MLFC can be used as part of a feedback to provide specified energy spreads for different energies.


  • Range and modulation dependencies for proton beam dose per monitor unit calculations

    by Wen C. Hsi, Andries N. Schreuder, Michael F. Moyers, Chris E. Allgower, Jonathan B. Farr, Anthony E. Mascia

    Calculations of dose per monitor unit (D∕MU) are required in addition to measurements to increase patient safety in the clinical practice of proton radiotherapy. As in conventional photon and electron therapy, the D∕MU depends on several factors. This study focused on obtaining range and modulation dependence factors used in D∕MU calculations for the double scattered proton beam line at the Midwest Proton Radiotherapy Institute. Three dependencies on range and one dependency on modulation were found. A carefully selected set of measurements was performed to discern these individual dependencies. Dependencies on range were due to: (1) the stopping power of the protons passing through the monitor chamber; (2) the reduction of proton fluence due to nuclear interactions within the patient; and (3) the variation of proton fluence passing through the monitor chamber due to different source‐to‐axis distances (SADs) for different beam ranges. Different SADs are produced by reconfigurations of beamline elements to provide different field sizes and ranges. The SAD effect on the D∕MU varies smoothly as the beam range is varied, except at the beam range for which the first scatterers are exchanged and relocated to accommodate low and high beam ranges. A geometry factor was devised to model the SAD variation effect on the D∕MU. The measured D∕MU variation as a function of range can be predicted within 1% using the three modeled dependencies on range. Investigation of modulated beams showed that an analytical formula can predict the D∕MU dependency as a function of modulation to within 1.5%. Special attention must be applied when measuring the D∕MU dependence on modulation to avoid interplay between range and SAD effects.


  • Dosimetric uncertainty in prostate cancer proton radiotherapy

    by Liyong Lin, Carlos Vargas, Wen Hsi, Daniel Indelicato, Roelf Slopsema, Zuofeng Li, Daniel Yeung, Dave Horne, Jatinder Palta

    Purpose: The authors we evaluate the uncertainty in proton therapy dose distribution for prostate cancer due to organ displacement, varying penumbra width of proton beams, and the amount of rectal gas inside the rectum. Methods and Materials: Proton beam treatment plans were generated for ten prostate patients with a minimum dose of 74.1 cobalt gray equivalent (CGE) to the planning target volume (PTV) while 95% of the PTV received 78 CGE. Two lateral or lateral oblique proton beams were used for each plan. The authors we investigated the uncertainty in dose to the rectal wall (RW) and the bladder wall (BW) due to organ displacement by comparing the dose‐volume histograms (DVH) calculated with the original or shifted contours. The variation between DVHs was also evaluated for patients with and without rectal gas in the rectum for five patients who had of visible rectal gas in their planning computed tomography (CT) imaging set. The uncertainty due to the varying penumbra width of the delivered protons for different beam setting options on the proton delivery system was also evaluated. Results: For a anterior shift, the relative change in the RW volume receiving 70 CGE dose was 37.9% (5.0% absolute change in 13.2% of a mean ). The relative change in the BW volume receiving 70 CGE dose was 20.9% (4.3% absolute change in 20.6% of a mean ) with a inferior shift. A penumbra difference in beam setting options on the proton delivery system resulted in the relative variations of 6.1% (0.8% absolute change) and 4.4% (0.9% absolute change) in of RW and BW, respectively. The data show that the organ displacements produce absolute DVH changes that generally shift the entire isodose line while maintaining the same shape. The overall shape of the DVH curve for each organ is determined by the penumbra and the distance of the target in beam's eye view (BEV) from the block edge. The beam setting option producing a sharper penumbra at the isocenter can reduce the magnitude of maximal doses to the RW by 2% compared to the alternate option utilizing the same block margin of . The dose to of the femoral head on the distal side of the lateral‐posterior oblique beam is increased by 25 CGE for a patient with of rectal gas. Conclusion: Variation in the rectal and bladder wall DVHs due to uncertainty in the position of the organs relative to the location of sharp dose falloff gradients should be accounted for when evaluating treatment plans. The proton beam delivery option producing a sharper penumbra reduces maximal doses to the rectal wall. Lateral‐posterior oblique beams should be avoided in patients prone to develop a large amount of rectal gas.


  • SU-GG-J-46: CINE-Magnetic Resonance Image Assessment of Intra-Fraction Prostate Motion

    by Wen C Hsi, Carlos Vargas, Anneyuko I Saito, James F Dempsey, Stella Flampouri, Zuofeng Li, Jatinder Palta

  • SU-EE-A2-06: Using Multi-Element Detector Arrays for Commissioning Active Wobbling and Energy-Stacking Proton Beams

    by Wen C Hsi, Dmitri Nichiporov, Chris Allgower, Jonathan Farr, Anthony Mascia, Niek Schreuder, Mark Wolanski