Review of non-invasive intracranial pressure measurement techniques for ophthalmology applications
- 8 November 2019
- journal article
- review article
- Published by BMJ in British Journal of Ophthalmology
- Vol. 104 (7) , 887-892
Abstract
Assessment and monitoring of intracranial pressure (ICP) are important in the management of traumatic brain injury and other cerebral pathologies. In the eye, ICP elevation and depression both correlate with optic neuropathies, the former because of papilledema and the latter related to glaucoma. While the relationship between ICP elevation and papilledema is well established, the relationship between low ICP and glaucoma is still poorly understood. So far, ICP monitoring is performed invasively, but this entails risks including infection, spurring the study of non-invasive alternatives. We review 11 methods of non-invasive estimation of ICP including correlation to optic nerve sheath diameter, intraocular pressure, ophthalmodynamometry and two-depth transcranial Doppler of the ophthalmic artery. While none of these methods can fully replace invasive techniques, certain measures show great potential for specific applications. Although only used in small studies to date, a MRI based method known as MR-ICP, appears to be the best non-invasive technique for estimating ICP, with two-depth transcranial ultrasound and ophthalmodynamometry showing potential as well.Keywords
Funding Information
- The contribution of the author Dr. Alice C. Verticchio Vercellin was supported by Fondazione Roma and by the Italian Ministry of Health
This publication has 63 references indexed in Scilit:
- Normal-Tension Glaucoma Has Normal Intracranial PressureOphthalmology, 2018
- Optic nerve sheath diameter measurement: a means of detecting raised ICP in adult traumatic and non-traumatic neurosurgical patientsThe American Journal of Emergency Medicine, 2017
- Neuroretinal rim area and ocular haemodynamic parameters in patients with normal-tension glaucoma with differing intracranial pressuresBritish Journal of Ophthalmology, 2015
- Ultrasonographic measured optic nerve sheath diameter as an accurate and quick monitor for changes in intracranial pressureJournal of Neurosurgery, 2015
- Optic Neuropathy Induced by Experimentally Reduced Cerebrospinal Fluid Pressure in MonkeysInvestigative Ophthalmology & Visual Science, 2014
- Revised diagnostic criteria for the pseudotumor cerebri syndrome in adults and childrenNeurology, 2013
- Use of the sonographic diameter of optic nerve sheath to estimate intracranial pressureThe American Journal of Emergency Medicine, 2013
- External Ventricular Drainage for Intraventricular HemorrhageCurrent Neurology and Neuroscience Reports, 2011
- Cerebrospinal Fluid Pressure in GlaucomaOphthalmology, 2010
- Cerebrospinal Fluid Pressure Is Decreased in Primary Open-angle GlaucomaOphthalmology, 2008