KeV-region analysis of the neutron capture cross-section of 237 Np
Authors:
- 30 August 2021
- journal article
- research article
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 59 (1) , 110-122
Abstract
Neutron capture cross-section measurements for Np have been conducted with the Accurate Neutron Nucleus Reaction Measurement Instrument (ANNRI) at the Materials and Life Science Facility (MLF) of the Japan Proton Accelerator Research Complex (J-PARC) using neutrons with energy ranging from thermal energy to 1 MeV. A time-of-flight (TOF) method using a NaI(Tl) detector was employed and the data were analyzed based on the pulse-height weighting technique in order to derive the neutron capture cross-section. The absolute capture cross-section was determined using the first resonance from JENDL-4.0 together with the total neutron flux derived from a Au sample measurement in which the first resonance was completely saturated. Both normalization techniques present agreement within 1 . The present results are also compared evaluated data libraries. There is a discrepancy of 10–25 discrepancy from 0.5 to 20 keV with JENDL-4.0. Nonetheless, above this energy JENDL-4.0 seems to reproduce the present data better as the results agree within uncertainties up to 500 keV. The cross-section results contain uncertainties below 4 from 0.5 to 30 keV. However, the total uncertainty increases to over 8 above 30 keV. Along with the cross-section measurement, theoretical calculations with the CCONE code were performed to reproduce the present results.
Keywords
This publication has 24 references indexed in Scilit:
- Correction of the thermal neutron capture cross section of 241Am obtained by the Westcott conventionJournal of Nuclear Science and Technology, 2016
- Pulse-width analysis for neutron capture cross-section measurement using an NaI(Tl) detectorNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014
- Cross-section measurement of237Np (n,????) from 10 meV to 1 keV at Japan Proton Accelerator Research ComplexJournal of Nuclear Science and Technology, 2013
- Measurement of thermal neutron capture cross sections of 237Np and 242Pu using prompt gamma neutron activationJournal of Radioanalytical and Nuclear Chemistry, 2012
- 1-MW Pulsed Spallation Neutron Source (JSNS) at J-PARCNeutron News, 2011
- JENDL-4.0: A New Library for Nuclear Science and EngineeringJournal of Nuclear Science and Technology, 2011
- ENDF/B-VII.0: Next Generation Evaluated Nuclear Data Library for Nuclear Science and TechnologyNuclear Data Sheets, 2006
- Emission Probabilities of Gamma Rays from the Decay of233Pa and238Np, and the Thermal Neutron Capture Cross Section of237NpJournal of Nuclear Science and Technology, 2006
- Measurements of Thermal Neutron Cross Section and Resonance Integral for237Np(n, γ)238Np ReactionJournal of Nuclear Science and Technology, 1994
- Capture-Cross-Section Studies for 30—220-keV Neutrons Using a New TechniquePhysical Review B, 1967