GRGerard Rovira

Gerard Rovira

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Gerard Rovira has a total of 181 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Direct Experiments of Neutron Capture on Stable and Unstable Isotopes for Stellar Nucleosynthesis Studies

    by Jorge Lerendegui-Marco, Javier Balibrea-Correa, Victor Babiano-Suarez, César Domingo-Pardo, Gabriel de la Fuente-Rosales, Bernardo Gameiro, Ion Ladarescu, Ariel Tarifeño-Saldivia, Pablo Torres-Sánchez, Oliver Aberle, et al.

    Neutron capture reactions provide essential nuclear physics input for modeling the synthesis of heavy elements in stars. The growing precision of stellar spectroscopy and isotopic measurements in presolar SiC grains now demands cross sections with improved accuracy over the full energy range, and access to unstable nuclei relevant to slow (s-) process branchings and the intermediate (i-) process. This article reviews recent progress in direct neutron capture measurements, focusing on time-of-flight (TOF) experiments at CERN n_TOF and complementary activation techniques. Substantial advances have been achieved for stable s-only and bottleneck isotopes, significantly improving constraints on s-process models. In parallel, the combination of high instantaneous neutron fluxes and advanced detector systems has facilitated first-time neutron capture measurements on several radioactive branching-point nuclei. Feasibility studies, however, reveal current limitations related to sample availability, background conditions, and restricted energy coverage. In this context, the complementarity between TOF and activation emerges as a central strategy. Future developments, including high-flux facilities and novel inverse kinematics experiments in ion storage rings, are expected to extend the boundaries of neutron capture measurements, overcoming current limitations and helping unlock new frontiers in our understanding of stellar nucleosynthesis.

  • Neutron total and capture cross-section measurement and resolved resonance analysis of Er

    by Gerard Rovira, Atsushi Kimura, Shoji Nakamura, Shunsuke Endo, Osamu Iwamoto, Nobuyuki Iwamoto, Tatsuya Katabuchi

  • Neutron capture cross section measurement of $^{129}$I and $^{127}$I using the NaI(Tl) spectrometer of the ANNRI beamline at J-PARC

    by Gerard Rovira, Atsushi Kimura, Shoji Nakamura, Shunsuke Endo, Osamu Iwamoto, Nobuyuki Iwamoto, Yosuke Toh, Mariko Segawa, Makoto Maeda, Tatsuya Katabuchi


  • Open Access

    Neutron Filtering System for Neutron Capture Cross Section Measurement at the ANNRI beamline of MLF/J-PARC

    by Gerard Rovira, Atsushi Kimura, Shoji Nakamura, Shunsuke Endo, Osamu Iwamoto, Nobuyuki Iwamoto, Tatsuya Katabuchi, Yu Kodama, Hideto Nakano, Jun-Ichi Hori, et al.

    A neutron filtering system has been designed and implemented in the Accurate Neutron-Nucleus Reaction Measurement Instrument (ANNRI) beamline in the Materials and Life Science (MLF) facility of the Japan Proton Accelerator Research Complex (J-PARC) to bypass the effect of the double-bunch mode of JPARC by molding the incident neutron flux into quasi-monoenergetic neutron beams. Filter assemblies using Fe, Si and Cr as filter materials were analyzed by means of experimental analysis, together with Monte Carlo simulations. The characteristics of the filtered neutron beam are presented and discussed alongside its viability in future applications for neutron cross-section measurements in the keV neutron region.

  • Neutron total and capture cross-section measurements of 155Gd and 157Gd in the thermal energy region with the Li-glass detectors and NaI(Tl) spectrometer installed in J-PARC·MLF·ANNRI

    by Atsushi Kimura, Shoji Nakamura, Shunsuke Endo, Gerard Rovira, Osamu Iwamoto, Nobuyuki Iwamoto, Hideo Harada, Tatsuya Katabuchi, Kazushi Terada, Jun-Ichi Hori, et al.

    Neutron total and capture cross–section measurements of 155Gd and 157Gd were performed with Li-glass detectors and a NaI(Tl) spectrometer in the ANNRI at the MLF of the J-PARC. The neutron total cross sections were determined in the energy region from 5 to 100 meV, and those at the thermal neutron energy were obtained to be 59.4 ± 1.7 and 251.9 ± 4.6 kilobarn for 155Gd and 157Gd, respectively. The neutron capture cross sections were determined in the energy region from 3.5 to 100 meV with an innovative method, and those at the thermal energy were obtained as 59.0 ± 2.5 and 247.4 ± 3.9 kilobarn for 155Gd and 157Gd, respectively. The present total and capture cross sections agree well within the standard deviations. The results for 155Gd were found to be consistent with the values in JENDL-4.0 and the experimental data given by Møller et al., Mastromarco et al. and Leinweber et al. Those for 157Gd agreed with the evaluated data in JENDL-4.0 and the experimental data by Møller et al. and Mastromarco et al. However, they disagree (11% larger) with the experimental result by Leinweber et al.


  • 241Am Neutron Capture Cross Section in the keV region using Si and Fe-filtered neutron beams

    by Gerard Rovira, Atsushi Kimura, Shoji Nakamura, Shunsuke Endo, Osamu Iwamoto, Nobuyuki Iwamoto, Tatsuya Katabuchi, Yu Kodama, Hideto Nakano

    The neutron capture cross-section of 241Am was measured in the keV neutron range using the recently implemented neutron filtering system of the Accurate Neutron-Nucleus Reaction Measurement Instrument (ANNRI) beamline in the materials and life science (MLF) facility of the Japan Proton Accelerator Research Complex (J-PARC). Filter arrays consisting of 20 cm of natFe and natSi were employed in separate measurements to provide filtered neutron beams with averaged neutron energies of 23.5 (Fe), 51.5 and 127.7 (Si) keV. The present 241Am results were obtained relative to the 197Au neutron capture yield by applying the total energy detection principle together with the pulse-height weighting technique. The 241Am neutron capture cross-section was determined as 2.72(29) b at 23.5 keV, 2.14(26) b at 51.5 keV and 1.32(10) b at 127.7 keV with total uncertainties in the range of 8 to 12%, much lower in comparison to the latest time-of-flight experimental data available. Graphical Abstract


  • Development of a neutron beam monitor with a thin plastic scintillator for nuclear data measurement using spallation neutron source

    by Hideto Nakano, Tatsuya Katabuchi, Gerard Rovira, Yu Kodama, Kazushi Terada, Atsushi Kimura, Shoji Nakamura, Shunshuke Endo

    A neutron monitoring detection system was developed for neutron capture cross-section measurement using a spallation neutron source. A combination of a plastic scintillator and a thin 6 LiF foil was adopted for the detector. The detector system was tested to study the feasibility of the system. Neutron irradiation experiments were conducted with the Accurate Neutron-Nucleus Reaction Measurement Instrument in the Materials and Life Science facility of the Japan Proton Accelerator Research Complex. A neutron time-of-flight spectrum was successfully measured without significant count loss or detector paralysis. GRAPHICAL ABSTRACT


  • KeV-neutron capture cross-section measurement of 197 Au with a Cr-filtered neutron beam at the ANNRI beamline of MLF/J-PARC

    by Gerard Rovira, Atsushi Kimura, Shoji Nakamura, Shunsuke Endo, Osamu Iwamoto, Nobuyuki Iwamoto, Tatsuya Katabuchi, Yu Kodama, Hideto Nakano, Yaoki Sato, et al.

    Cr-filtered keV-neutron experiments were performed in the Accurate Neutron-Nucleus Reaction Measurement Instrument (ANNRI) beamline in the Materials and Life Science (MLF) facility of the Japan Proton Accelerator Research Complex (J-PARC) to measure the neutron capture cross-section of 197Au. The energy range of the neutron filtering system at ANNRI was extended through the use of 15 cm of natCr as filter material to tailor quasi-monochromatic neutron peaks with averaged neutron energies of 133.4 and 45.0 keV. The performance of the natCr filter assembly was evaluated by means of experimental capture and transmission analyses, together with the use of Monte-Carlo simulations. The present 197Au neutron capture cross-section results provide agreement within uncertainties with the JENDL-4.0 evaluated library and the IAEA standard data library further demonstrating the capabilities of the neutron filtering system at ANNRI.


  • Neutron capture and total cross-section measurements and resonance parameter analysis of niobium-93 below 400 eV

    by Shunsuke Endo, Atsushi Kimura, Shoji Nakamura, Osamu Iwamoto, Nobuyuki Iwamoto, Gerard Rovira, Kazushi Terada, Shin-Ichiro Meigo, Yosuke Toh, Mariko Segawa, et al.

    Neutron capture yields and transmission ratios of 93Nb were measured by applying the time-of-flight method using the Accurate Neutron-Nucleus Reaction measurement Instrument of the Materials and Life Science Experimental Facility at the Japan Proton Accelerator Research Complex. Nb metal foils were used as samples. Germanium gamma-ray and Li-glass neutron detectors were used for capture yields and transmission ratio measurements, respectively. The pulse height weighting technique was applied to deduce the capture cross-sections from 0.01 to 400 eV, and the thermal-neutron capture cross-section was determined to be 0.97 ± 0.11 b. The total cross-sections were derived from transmission ratios ranging from 0.2 to 400 eV. The resonance parameters of 93Nb below 400 eV were determined based on the obtained capture cross-sections and transmission ratios using the resonance analysis code, REFIT, and compared with the parameters given by past measurements and the evaluated nuclear data library, JENDL-4.0.


  • KeV-region analysis of the neutron capture cross-section of 237 Np

    by Gerard Rovira, Tatsuya Katabuchi, Kenichi Tosaka, Shota Matsuura, Yu Kodama, H. Nakano, Osamu Iwamoto, Atsushi Kimura, Shoji Nakamura, Nobuyuki Iwamoto

    Neutron capture cross-section measurements for  237Np have been conducted with the Accurate Neutron Nucleus Reaction Measurement Instrument (ANNRI) at the Materials and Life Science Facility (MLF) of the Japan Proton Accelerator Research Complex (J-PARC) using neutrons with energy ranging from thermal energy to 1 MeV. A time-of-flight (TOF) method using a NaI(Tl) detector was employed and the data were analyzed based on the pulse-height weighting technique in order to derive the neutron capture cross-section. The absolute capture cross-section was determined using the first resonance from JENDL-4.0 together with the total neutron flux derived from a  197Au sample measurement in which the first resonance was completely saturated. Both normalization techniques present agreement within 1 %. The present results are also compared evaluated data libraries. There is a discrepancy of 10–25 % discrepancy from 0.5 to 20 keV with JENDL-4.0. Nonetheless, above this energy JENDL-4.0 seems to reproduce the present data better as the results agree within uncertainties up to 500 keV. The cross-section results contain uncertainties below 4 % from 0.5 to 30 keV. However, the total uncertainty increases to over 8 % above 30 keV. Along with the cross-section measurement, theoretical calculations with the CCONE code were performed to reproduce the present results.