A method of dose reconstruction for moving targets compatible with dynamic treatments
Authors:
- Per Rugaard PoulsenPPPer Rugaard Poulsen
- Mai Lykkegaard SchmidtMSMai Lykkegaard Schmidt
- Paul KeallPKPaul Keall
- Esben Schjødt WormEWEsben Schjødt Worm
- Walther FledeliusWFWalther Fledelius
- Lone HoffmannLHLone Hoffmann
- 25 September 2012
- journal article
- Published by Wiley in Medical Physics
- Vol. 39 (10) , 6237-6246
Abstract
Purpose: To develop a method that allows a commercial treatment planning system (TPS) to perform accurate dose reconstruction for rigidly moving targets and to validate the method in phantom measurements for a range of treatments including intensity modulated radiation therapy (IMRT), volumetric arc therapy (VMAT), and dynamic multileaf collimator (DMLC) tracking.Methods: An in‐house computer program was developed to manipulate Dicom treatment plans exported from a TPS (Eclipse, Varian Medical Systems) such that target motion during treatment delivery was incorporated into the plans. For each treatment, a motion including plan was generated by dividing the intratreatment target motion into 1 mm position bins and construct sub‐beams that represented the parts of the treatment that were delivered, while the target was located within each position bin. For each sub‐beam, the target shift was modeled by a corresponding isocenter shift. The motion incorporating Dicom plans were reimported into the TPS, where dose calculation resulted in motion including target dose distributions. For experimental validation of the dose reconstruction a thorax phantom with a moveable lung equivalent rod with a tumor insert of solid water was first CT scanned. The tumor insert was delineated as a gross tumor volume (GTV), and a planning target volume (PTV) was formed by adding margins. A conformal plan, two IMRT plans (step‐and‐shoot and sliding windows), and a VMAT plan were generated giving minimum target doses of 95% (GTV) and 67% (PTV) of the prescription dose (3 Gy). Two conformal fields with MLC leaves perpendicular and parallel to the tumor motion, respectively, were generated for DMLC tracking. All treatment plans were delivered to the thorax phantom without tumor motion and with a sinusoidal tumor motion. The two conformal fields were delivered with and without portal image guided DMLC tracking based on an embedded gold marker. The target dose distribution was measured with a radiochromic film in the moving rod and compared with the reconstructed doses using gamma tests.Results: Considerable interplay effects between machine motion and target motion were observed for the treatments without tracking. For nontracking experiments, the mean 2 mm/2% gamma pass rate over all investigated scenarios was 99.6% between calculated and measured doses. For tracking experiments, the mean gamma pass rate was 99.4%.Conclusions: A method for accurate dose reconstruction for moving targets with dynamic treatments was developed and experimentally validated in a variety of delivery scenarios. The method is suitable for integration into TPSs, e.g., for reconstruction of the dose delivered to moving tumors or calculation of target doses delivered with DMLC tracking.Keywords
This publication has 24 references indexed in Scilit:
- Megavoltage Image-Based Dynamic Multileaf Collimator Tracking of a NiTi Stent in Porcine Lungs on a Linear AcceleratorInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Characterization and optimization of EBT2 radiochromic films dosimetry system for precise measurements of output factors in small fields used in radiotherapyRadiation Measurements, 2012
- Motion-compensated estimation of delivered dose during external beam radiation therapy: Implementation in Philips’ Pinnacle3treatment planning systemMedical Physics, 2011
- Dosimetric Effect of Intrafraction Motion and Residual Setup Error for Hypofractionated Prostate Intensity-Modulated Radiotherapy With Online Cone Beam Computed Tomography Image GuidanceInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- Dosimetric validation of the Acuros XB Advanced Dose Calculation algorithm: fundamental characterization in waterPhysics in Medicine & Biology, 2011
- A computational method for estimating the dosimetric effect of intra-fraction motion on step-and-shoot IMRT and compensator plansPhysics in Medicine & Biology, 2010
- Dosimetric validation of the anisotropic analytical algorithm for photon dose calculation: fundamental characterization in waterPhysics in Medicine & Biology, 2006
- Effects of motion on the total dose distributionSeminars in Radiation Oncology, 2004
- Verification of dynamic and segmental IMRT delivery by dynamic log file analysisJournal of Applied Clinical Medical Physics, 2002
- A method for incorporating organ motion due to breathing into 3D dose calculationsMedical Physics, 1999