Abstract
This paper presents a simple and effective method to extract the identification quantity of transient pulse waveform produced by the overhead transmission line short-circuit fault. This method employs the second-order time harmonic equation of the power frequency component to convert the fault full-wave data. After the conversion, only the identification quantity remains. This method can amplify high-frequency spectral content by the times of the square of the angular frequency, and hence improve the sensitivity of identifying fault transient. Using the identification quantity, one can clearly observe the arrival time and relative intensity of fault transient. A three-phase half wavelength transmission line of 50Hz/3000km is simulated with PSCAD to illuminate the effectiveness of this method. The effects of fault type, soil resistivity, fault resistance, power frequency fluctuation, sampling rate, transposition length,fault inception angle and white noise are analyzed. Calculated results show that this method can distinguish different fault type and can work effectively at low sampling rate down to 10kHz. This method is helpful for improving the performance of the traveling-wave based fault location method.Keywords
Funding Information
- Science and technology Project of State Grid Corporation of China (5100-201955404A-0-0-00)
This publication has 31 references indexed in Scilit:
- Transient Electromagnetic Disturbance Induced on the Ports of Intelligent Component of Electronic Instrument Transformer Due to Switching Operations in 500 kV GIS SubstationsIEEE Access, 2017
- Fault investigation methods on power transmission line: A comparative study2016
- Characteristics of Electromagnetic Disturbance for Intelligent Component Due to Switching Operations via a 1100 kV AC GIS Test CircuitIEEE Transactions on Power Delivery, 2016
- Fault detection, classification and location for transmission lines and distribution systems: a review on the methodsHigh Voltage, 2016
- Maximum Limit of Allowable Ground Potential Rise of Substation Grounding SystemIEEE Transactions on Industry Applications, 2015
- Influence of Potential Difference Within Large Grounding Grid on Fault Current Division FactorIEEE Transactions on Power Delivery, 2013
- Impact of seasonal variation of soil resistivity on safety of substation grounding system2013
- Comparison of simulated and recorded transients for travelling wave fault location2004
- Nonuniform three-phase power lines: resonance effects due to conductor transpositionInternational Journal of Electrical Power & Energy Systems, 2004
- Application of clarke's transformation to the modal analysis of asymmetrical single‐circuit three‐phase line configurationsEuropean Transactions on Electrical Power, 2000