Novel rotatable tabletop for total-body irradiation using a linac-based VMAT technique
Open Access
- 30 December 2019
- journal article
- research article
- Published by Springer Nature in Radiation Oncology
- Vol. 14 (1) , 1-10
Abstract
Background: Volumetric Modulated Arc Therapy (VMAT) techniques have recently been implemented in clinical practice for total-body irradiation (TBI). To date, most techniques still use special couches, translational tables, or other self-made immobilization devices for dose delivery. Aim of the present study was to report the first results of a newly developed rotatable tabletop designed for VMAT-TBI.Methods: The VMAT-TBI technique theoretically allows the use of any standard positioning device at the linear accelerator. Nevertheless, the main problem is that patients taller than 120 cm cannot be treated in one position due to the limited cranial-caudal couch shift capacities of the linac. Therefore, patients are usually turned from a head-first supine position (HFS) to a feet-first supine position (FFS) to overcome this limitation. The newly developed rotatable tabletop consists completely of carbon fiber, including the ball bearing within the base plate of the rotation unit. The patient can be turned 180° from a HFS to a FFS position within a few seconds, without the need of repositioning.Results: The first 20 patients had a median age of 47 years, and received TBI before bone marrow transplantation for acute myeloid leukemia. Most patients (13/20) received a TBI dose of 4 Gy in 2 fractions, twice daily. The mean number of applied monitor units (MU) was 6476 MU using a multi-arcs and multi-isocenter VMAT-TBI technique.The tabletop has been successfully used in daily clinical practice and helped to keep the treatment times at an acceptable level. During the first treatment fraction, the mean overall treatment time (OTT) was 57 min. Since no additional image guidance was used in fraction 2 of the same day, the OTT was reduced to mean 38 min.Conclusions: The easy and reproducible rotation of the patient on the treatment couch using the rotatable tabletop, is time-efficient and overcomes the need of repositioning the patient after turning from a HFS to a FFS position during VMAT TBI. Furthermore, it prevents couch-gantry collisions, incorrect isocenter shifts and beam mix-up due to predicted absolute table coordinates, which are recorded to the R + V system with the corresponding beams.Keywords
Funding Information
- IT-V (na)
This publication has 29 references indexed in Scilit:
- Intensity-modulated Total Body Irradiation (TBI) with TomoDirect™Radiation Oncology, 2015
- The use of positron emission tomography/computed tomography imaging in radiation therapy: a phantom study for setting internal target volume of biological target volumeRadiation Oncology, 2015
- Extreme heterogeneity of myeloablative total body irradiation techniques in clinical practice: A survey of the Acute Leukemia Working Party of the European Group for Blood and Marrow TransplantationCancer, 2014
- Arc therapy for total body irradiation – A robust novel treatment technique for standard treatment roomsRadiotherapy and Oncology, 2014
- Interplay effects between dose distribution quality and positioning accuracy in total marrow irradiation with volumetric modulated arc therapyMedical Physics, 2013
- Total Body Irradiation (TBI) using Helical Tomotherapy in children and young adults undergoing stem cell transplantationRadiation Oncology, 2013
- Radiotherapy in marginal zone lymphomaRadiation Oncology, 2013
- Inverse‐planned modulated‐arc total‐body irradiationMedical Physics, 2012
- Aperture modulated, translating bed total body irradiationMedical Physics, 2011
- Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithmMedical Physics, 1999