Comparison of T1wFLAIR and T1wTSE sequences in imaging the brain of small animals using high-field MRI
Open Access
- 6 July 2019
- journal article
- research article
- Published by Springer Nature in Irish Veterinary Journal
- Vol. 72 (1) , 1-10
Abstract
T1w turbo spin echo (TSE) represents a fundamental sequence in magnetic resonance imaging (MRI) protocols investigating the brain. Recent human literature has reported T1w Fluid Attenuated Inversion Recovery’s (FLAIR’s), superiority to T1wTSE in relation to tissue contrast for grey-to-white matter (GM-WM) and lesion-to-WM, although conflicting results are reported concerning lesion detection. To the author’s knowledge, T1wFLAIR has not been investigated in veterinary medicine. The aim of this prospective study was to determine quantitatively and qualitatively which sequence provides better overall better image quality both pre- and post-gadolinium. Twenty-eight animals underwent MRI of the brain with T1wTSE and T1wFLAIR sequences performed with equivalent mean acquisition times. Quantitative assessment of the sequences was undertaken using contrast-to-noise (CNR) and signal-to-noise (SNR) ratios from predefined locations. T1wFLAIR provided a better CNR compared to T1wTSE, while T1wTSE provided better SNR due to the higher noise levels of T1wFLAIR images. Qualitative assessment of the sequences was performed using Visual Grading Analysis Scoring (VGAS) for a number of criteria by three observers on two separate occasions. T1wFLAIR performed better for cerebrospinal fluid (CSF) suppression, white-to-grey matter (WM-GM) and white matter-to-CSF (WM-to-CSF) definition in both pre- and post-contrast images whereas the T1wTSE sequence was less affected by noise levels. The individual parameter for overall image quality found no significant difference between the two sequences. However, the composite VGAS favored T1wFLAIR as the preferred sequence. Although case numbers were insufficient for statistical analysis, comparison of the sequences indicates that lesion definition and margination was better in T1wFLAIR pre-contrast images, however post-contrast lesion detection was almost equivalent between sequences with slightly better margination in the T1wTSE sequence. T1wFLAIR provides better CNR with better WM-GM and WM-CSF definition both pre- and post-contrast compared to T1wTSE albeit with a higher degree of noise; this was confirmed both quantitatively and qualitatively. Our results also suggest that T1wFLAIR is better for lesion detection and margination pre-contrast administration and sequences are relatively equivocal post-gadolinium administration although further research is required to determine the benefit that inversion recovery sequences make when investigating brain lesions in small animal MRI.Keywords
This publication has 23 references indexed in Scilit:
- CLINICAL AUDIT OF IMAGE QUALITY IN RADIOLOGY USING VISUAL GRADING CHARACTERISTICS ANALYSISRadiation Protection Dosimetry, 2015
- Diagnostic imaging – evaluating image quality using visual grading characteristic (VGC) analysisVeterinary Research Communications, 2010
- Evaluating imaging systems: practical applicationsRadiation Protection Dosimetry, 2010
- Fat and water magnetic resonance imagingJournal of Magnetic Resonance Imaging, 2009
- CONTRAST‐ENHANCED FLUID‐ATTENUATED INVERSION RECOVERY VS. CONTRAST‐ENHANCED SPIN ECHO T1‐WEIGHTED BRAIN IMAGINGVeterinary Radiology & Ultrasound, 2008
- Usefulness of T1-weighted image with fast inversion recovery technique in intracranial lesions: comparison with T1-weighted spin echo image.Clinical Imaging, 2000
- Methods for the Evaluation of Image Quality: A ReviewRadiation Protection Dosimetry, 2000
- T1‐Weighted MR imaging of the brain using a fast inversion recovery pulse sequenceJournal of Magnetic Resonance Imaging, 1996
- The intrinsic signal‐to‐noise ratio in NMR imagingMagnetic Resonance in Medicine, 1986
- MR ImagingJournal of Computer Assisted Tomography, 1985