CBChiara Bergamino

Chiara Bergamino

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Chiara Bergamino has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Hypertensive nonobstructive hydrocephalus as main magnetic resonance imaging feature in a dog with disseminated choroid plexus carcinomatosis

    by Lea Carisch, Lorenzo Golini, Lea Schurna, Chiara Bergamino, Katrin M. Beckmann, Monika Hilbe, Thanaporn Asawapattanakul, Wolfgang Baumgärtner, Christina Puff, Adriano Wang-Leandro

    Obstructive or nonobstructive hypertensive hydrocephalus is reported in choroid plexus tumors. Choroid plexus tumors typically present as T2-weighted hyperintense intraventricular masses with occasional cerebrospinal fluid-drop metastasis. Acquired neoplastic nonobstructive hydrocephalus without visible mass lesion in magnetic resonance imaging is not reported in dogs. A 4.5-year-old Rhodesian Ridgeback presented with reduced mental status, unilaterally absent pupillary light reflex, and neck pain. Magnetic resonance imaging revealed a nonobstructive hydrocephalus and widened lumbar subarachnoid space with no evidence of a primary mass lesion. Postmortem examination confirmed a disseminated choroid plexus tumor affecting the ependyma and choroid plexi of all ventricles and the cerebral and lumbar subarachnoid space. Disseminated choroid plexus carcinomatosis should be considered as a possible cause of hypertensive hydrocephalus even in absence of a primary mass.


  • Open Access

    Comparison of T1wFLAIR and T1wTSE sequences in imaging the brain of small animals using high-field MRI

    by Chiara Bergamino, Séamus Hoey, Kenneth Waller, Cliona Skelly

    T1w turbo spin echo (TSE) represents a fundamental sequence in magnetic resonance imaging (MRI) protocols investigating the brain. Recent human literature has reported T1w Fluid Attenuated Inversion Recovery’s (FLAIR’s), superiority to T1wTSE in relation to tissue contrast for grey-to-white matter (GM-WM) and lesion-to-WM, although conflicting results are reported concerning lesion detection. To the author’s knowledge, T1wFLAIR has not been investigated in veterinary medicine. The aim of this prospective study was to determine quantitatively and qualitatively which sequence provides better overall better image quality both pre- and post-gadolinium. Twenty-eight animals underwent MRI of the brain with T1wTSE and T1wFLAIR sequences performed with equivalent mean acquisition times. Quantitative assessment of the sequences was undertaken using contrast-to-noise (CNR) and signal-to-noise (SNR) ratios from predefined locations. T1wFLAIR provided a better CNR compared to T1wTSE, while T1wTSE provided better SNR due to the higher noise levels of T1wFLAIR images. Qualitative assessment of the sequences was performed using Visual Grading Analysis Scoring (VGAS) for a number of criteria by three observers on two separate occasions. T1wFLAIR performed better for cerebrospinal fluid (CSF) suppression, white-to-grey matter (WM-GM) and white matter-to-CSF (WM-to-CSF) definition in both pre- and post-contrast images whereas the T1wTSE sequence was less affected by noise levels. The individual parameter for overall image quality found no significant difference between the two sequences. However, the composite VGAS favored T1wFLAIR as the preferred sequence. Although case numbers were insufficient for statistical analysis, comparison of the sequences indicates that lesion definition and margination was better in T1wFLAIR pre-contrast images, however post-contrast lesion detection was almost equivalent between sequences with slightly better margination in the T1wTSE sequence. T1wFLAIR provides better CNR with better WM-GM and WM-CSF definition both pre- and post-contrast compared to T1wTSE albeit with a higher degree of noise; this was confirmed both quantitatively and qualitatively. Our results also suggest that T1wFLAIR is better for lesion detection and margination pre-contrast administration and sequences are relatively equivocal post-gadolinium administration although further research is required to determine the benefit that inversion recovery sequences make when investigating brain lesions in small animal MRI.


  • Improved visualization of the lumbar spine nerve roots in dogs using water excitation (ProSet) as opposed to short tau inversion recovery: A retrospective study of two fat suppression MRI sequences

    by Chiara Bergamino, Séamus E. Hoey, Marie de Swarte, Cliona Skelly

    Magnetic resonance imaging fat suppression techniques are commonly used for diagnosis of canine spinal disease, however, studies comparing different techniques are currently lacking. This retrospective, methods comparison study aimed to evaluate water excitation and STIR MRI pulse sequences for visualization of canine lumbar spinal nerve roots. For inclusion, all dogs had to have dorsal planar MRI studies of the lumbar spine using both sequences. Visual grading analysis was used for scoring the following five criteria: degree of fat suppression; nerve root visualization; subjective tissue contrast; presence of noise; and overall better image quality. Scores were independently recorded by three board‐certified veterinary radiologists on two separate occasions, 3‐6 weeks apart. A total of 90 dogs were sampled. A two‐tailedt‐test showed that there were significant differences in all scored parameters (P < 0.00001), with the exception of noise (P = 0.47343), and that the water excitation sequence scored higher in all cases excluding noise. A Gwets AC kappa for intraobserver and interobserver reliability showed “almost perfect” agreement for the nerve roots in both tests (intra:k = 0.88; inter:k = 0.90). Intraobserver agreement was “substantial” for the degree of fat suppression (k = 0.68), subjective tissue contrast (k = 0.75), and overall better image quality (k = 0.76) and it was “fair” for the noise (k = 0.46). Interobserver agreement was “moderate” for the degree of fat suppression (k = 0.53), subjective tissue contrast (k = 0.63), and overall better image quality (k = 0.66) and “slight” for noise (k = 0.25). These findings supported using the water excitation pulse sequence for fat‐suppressed MRI of canine lumbar spinal nerve roots.