Monitoring of the Analytical Performance of Four Different Blood Glucose Monitoring Systems: A Post-market Performance Follow-Up Study
Authors:
Open Access
- 28 October 2024
- journal article
- research article
- Published by Springer Nature in Diabetes Therapy
- Vol. 15 (12) , 2525-2535
Abstract
Introduction A sizeable minority of commercially available blood glucose monitoring (BGM) systems fail to satisfy regulatory accuracy requirements, such as ISO 15197:2013, after approval. This study assessed whether the BGMs tested could consistently meet these ISO requirements by investigating their accuracy in a non-standardized setting. Methods In this 18-month post-market performance study, using the ISO criteria, healthcare professionals tested the accuracy of four CE-marked BGM systems (Roche Diabetes Care, Mannheim, Germany) on European adults with diabetes mellitus. ISO criteria included 95% of blood glucose (BG) values being within ± 15 mg/dl of a reference measurement for BG < 100 mg/dl or ± 15% for BG ≥ 100 mg/dl and, in the Parkes Consensus Error grid for type 1 diabetes comparing capillary BGM measurements versus reference method, 99% of BG values falling within zone A (no effect on clinical action or outcome) and zone B (altered clinical action with little or no effect on clinical outcome). Results BGM readings were obtained from 1650 participants, and the number of readings per BGM system was between 1712 and 2376. The percentage of BGM readings that fell within ISO 15197:2013 limits ranged from 99.4 to 99.9%. For all meter types, 100% of data points fell within zone A or zone B, and most data points for each meter (≥ 99.9%) were in zone A. Conclusion All four CE-marked BGM models showed results within the accuracy limits defined by ISO 15197 in a non-standardized setting and thus consistently met regulatory accuracy requirements.Keywords
Funding Information
- Roche Diabetes Care
This publication has 16 references indexed in Scilit:
- Self-Monitoring of Blood Glucose as an Integral Part in the Management of People with Type 2 Diabetes MellitusDiabetes Therapy, 2022
- System accuracy evaluation of 18 CE-marked current-generation blood glucose monitoring systems based on EN ISO 15197:2015BMJ Open Diabetes Research & Care, 2020
- A Review of Blood Glucose Monitor AccuracyDiabetes Technology & Therapeutics, 2018
- System Accuracy Evaluation of Different Blood Glucose Monitoring Systems Following ISO 15197:2013 by Using Two Different Comparison MethodsDiabetes Technology & Therapeutics, 2015
- Accuracy of Blood Glucose Meters for Self-Monitoring Affects Glucose Control and Hypoglycemia Rate in Children and Adolescents with Type 1 DiabetesDiabetes Technology & Therapeutics, 2015
- System Accuracy of Blood Glucose Monitoring Systems: Impact of Use by Patients and Ambient ConditionsDiabetes Technology & Therapeutics, 2013
- Clinical Implications and Economic Impact of Accuracy Differences among Commercially Available Blood Glucose Monitoring SystemsJournal of Diabetes Science and Technology, 2013
- Factors Affecting Blood Glucose Monitoring: Sources of Errors in MeasurementJournal of Diabetes Science and Technology, 2009
- Instruments for Self-Monitoring of Blood Glucose: Comparisons of Testing Quality Achieved by Patients and a TechnicianClinical Chemistry, 2002
- The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes MellitusThe New England journal of medicine, 1993