JRJulia Roetschke

Julia Roetschke

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Julia Roetschke has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Glucagon-like Peptide-1-Based Therapies Do Not Interfere With Blood Glucose Monitoring Systems

    by Julia K. Mader, Brian Huffman, Robert Sharon, Gabriela Bucklar, Julia Roetschke

  • Open Access

    Monitoring of the Analytical Performance of Four Different Blood Glucose Monitoring Systems: A Post-market Performance Follow-Up Study

    by Julia K. Mader, Annette Baumstark, Johannes Tüting, Günter Sokol, Ruth Schuebel, Yuhong Tong, Julia Roetschke, Robbert J. Slingerland

    Introduction A sizeable minority of commercially available blood glucose monitoring (BGM) systems fail to satisfy regulatory accuracy requirements, such as ISO 15197:2013, after approval. This study assessed whether the BGMs tested could consistently meet these ISO requirements by investigating their accuracy in a non-standardized setting. Methods In this 18-month post-market performance study, using the ISO criteria, healthcare professionals tested the accuracy of four CE-marked BGM systems (Roche Diabetes Care, Mannheim, Germany) on European adults with diabetes mellitus. ISO criteria included 95% of blood glucose (BG) values being within ± 15 mg/dl of a reference measurement for BG < 100 mg/dl or ± 15% for BG ≥ 100 mg/dl and, in the Parkes Consensus Error grid for type 1 diabetes comparing capillary BGM measurements versus reference method, 99% of BG values falling within zone A (no effect on clinical action or outcome) and zone B (altered clinical action with little or no effect on clinical outcome). Results BGM readings were obtained from 1650 participants, and the number of readings per BGM system was between 1712 and 2376. The percentage of BGM readings that fell within ISO 15197:2013 limits ranged from 99.4 to 99.9%. For all meter types, 100% of data points fell within zone A or zone B, and most data points for each meter (≥ 99.9%) were in zone A. Conclusion All four CE-marked BGM models showed results within the accuracy limits defined by ISO 15197 in a non-standardized setting and thus consistently met regulatory accuracy requirements.


  • Open Access

    Pragmatic Study Design to Assess the Effect of a mHealth Application on Empowerment of Noninsulin Treated Type 2 Diabetes People in a Low- and Middle-income Setup

    by Kesavadev Jothydev, Ehrmann Dominic, Bloethner Sandra, Wagner Katja, Gala Vishal, Roetschke Julia

    Background: In low- and middle-income countries (LMICs), such as India, self-monitoring of blood glucose (SMBG) for people living with type 2 diabetes mellitus (T2DM) faces many barriers. mHealth applications that combine blood glucose (BG) assessment and the provision of actionable information can help overcome current challenges. Pragmatic study protocols assessing the medical value of mobile SMBG applications to deal with LMIC-specific challenges are missing. Aims and Objectives: This study will assess the impact of a mHealth application on diabetes empowerment using the Diabetes Empowerment Scale-Short Form questionnaire in noninsulin-treated people with T2DM in India. Methods: An observational, single-arm, prospective study will be conducted among adults (n = 100) with T2DM who have not been using a BG meter before and were on diet, exercise, or noninsulin antidiabetic therapy. After enrollment (baseline) and an 8-week control phase, the people participating in the study will receive the mobile phone-based BG assessment devices and will receive a training for the application. During the observational period of 12 weeks (20 weeks after baseline), the subjects will monitor their BG ranges with the devices and the mobile application. At baseline and weeks 8, 14, and 20, diabetes empowerment will be assessed as primary outcome. Health literacy, diabetes treatment satisfaction, and user experience, among others, will be examined as secondary outcomes. Discussion: Mobile applications have the potential to improve diabetes care due to their higher reach, but pragmatic study designs are needed to evaluate the effectiveness. Conclusions: The results of this pragmatic study will provide more patient-reported insights on the impact of mobile applications on diabetes self-management in LMIC.

  • Open Access

    Evaluation of Patient-facing Health Application Features to Support Self-management of People Living with Prediabetes or Type 2 Diabetes Mellitus – A Health-care Professional Perspective

    by Jothydev Kesavadev, Vishal Gala, Julia Roetschke

    Background: Diabetes mellitus (DM) remains a significant chronic disease worldwide. Effective self-management is essential for optimal glycemic control and preventing long-term complications in people with DM (PWD). In recent years, e-health applications have emerged to support the self-management of individuals with type 2 DM (T2DM) in particular regarding the evaluation of blood glucose (BG) levels. However, numerous challenges still exist. Aims and Objectives: This questionnaire-based study aimed to understand the knowledge, attitude, and practice regarding a novel e-health application to monitor BG levels using a smartphone camera that is designed for individuals with prediabetes or T2DM in low- and middle-income countries. Materials and Methods: An open-ended questionnaire guide was used to investigate the PWD’s needs from a health-care professional’s (HCP) perspective and the challenges that could be addressed by new features of the health application. Responses were graded on a 5-point ordinal scale and evaluated to identify advantages, disadvantages, and suggestions to improve the proposed features. Results: The HCPs highlighted the application’s simplicity and convenience of use, the mobile device-based measurement of BG ranges, the step-by-step guided features, and lifestyle advice. They suggested improvements such as a one-step handling approach and quantitative versus qualitative BG level assessment. Conclusion: It is expected that younger and technologically proficient individuals with T2DM will benefit the most from this application. However, further research is necessary to assess how the proposed features affect individuals’ empowerment in managing diabetes and the distress associated with the burden of self-management.