Allergic reaction and metal hypersensitivity after shoulder joint replacement
Open Access
- 1 November 2021
- journal article
- research article
- Published by Springer Nature in MUSCULOSKELETAL SURGERY
- Vol. 107 (1) , 55-68
Abstract
Purpose: Metal ion release may cause local and systemic effects and induce hypersensitivity reactions. The aim of our study is first to determine if implant-related hypersensitivity correlates to patient symptoms or not; second, to assess the rate of hypersensitivity and allergies in shoulder arthroplasty. Methods: Forty patients with shoulder replacements performed between 2015 and 2017 were studied with minimum 2-year follow-up; no patient had prior metal implants. Each patient underwent radiographic and clinical evaluation using the Constant-Murley Score (CMS), 22 metal and cement haptens patch testing, serum and urine tests to evaluate 12 metals concentration, and a personal occupational medicine interview. Results: At follow-up (average 45 ± 10.7 months), the mean CMS was 76 ± 15.9; no clinical complications or radiographic signs of loosening were detected; two nickel sulfate (5%), 1 benzoyl peroxide (2.5%) and 1 potassium dichromate (2.5%) positive findings were found, but all these patients were asymptomatic. There was an increase in serum aluminum, urinary aluminum and urinary chromium levels of 1.74, 3.40 and 1.83 times the baseline, respectively. No significant difference in metal ion concentrations were found when patients were stratified according to gender, date of surgery, type of surgery, and type of implant. Conclusions: Shoulder arthroplasty is a source of metal ion release and might act as a sensitizing exposure. However, patch test positivity does not seem to correlate to hypersensitivity cutaneous manifestations or poor clinical results. Laboratory data showed small constant ion release over time, regardless of gender, type of shoulder replacement and implant used. Levels of evidence: Level II.Keywords
Funding Information
- Università degli Studi di Torino
This publication has 48 references indexed in Scilit:
- Allergic complications from orthopaedic joint implants: the role of delayed hypersensitivity to benzoyl peroxide in bone cementContact Dermatitis, 2011
- The potential role of metal ion release as a marker of loosening in patients with total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2010
- The association between metal allergy, total hip arthroplasty, and revisionActa Orthopaedica, 2009
- Problems and progresses in speciation of Al in human serum: An overviewJournal of Inorganic Biochemistry, 2009
- Patch testing with benzoyl peroxide: reaction profile and interpretation of positive patch test reactionsContact Dermatitis, 2009
- Serum ion levels after ceramic‐on‐ceramic and metal‐on‐metal total hip arthroplasty: 8‐year minimum follow‐upJournal of Orthopaedic Research, 2008
- Benzoyl peroxide: is it a relevant bone cement allergen in patients with orthopaedic implants?Contact Dermatitis, 2007
- Serum aluminium and cobalt levels after ceramic-on-ceramic and metal-on-metal total hip replacementThe Journal of Bone and Joint Surgery. British volume, 2006
- Sensitivity to implant materials in patients undergoing total hip replacementJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2005
- An allergic reaction after internal fixation of a fracture using a Vitallium plateJournal of Allergy and Clinical Immunology, 1973