A. Ferrario
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
A. Ferrario has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Pautasso
Orthopaedic and Traumatology Department, ASST Sette Laghi – Circolo Hospital and Macchi Foundation in Varese - University Hospital, Varese, Italy
1 shared publication - Enrico Bellato
Department of Surgical Sciences, University of Turin, Turin, Italy
1 shared publication - Enrico Pira
Department of Public Health and Pediatrics, University of Turin, P.zza Polonia 94, 10126 Turin, Italy
1 shared publication - F. Castoldi
University of Turin, Turin, Italy
1 shared publication - Ilaria Zorzolo
Department of Orthopaedics and Traumatology, Maria Vittoria Hospital, Turin, Italy, Turin, Italy
1 shared publication - Pietro Pellegrino
S.C. Orthopedic Oncological Surgery, AOU Città della Salute e della Scienza, Torino, Italy
1 shared publication
Latest Publications
- Open Access
- 1 November 2021
- Published by Springer Nature in MUSCULOSKELETAL SURGERY
- Vol. 107 (1) , 55-68
Allergic reaction and metal hypersensitivity after shoulder joint replacement
Purpose: Metal ion release may cause local and systemic effects and induce hypersensitivity reactions. The aim of our study is first to determine if implant-related hypersensitivity correlates to patient symptoms or not; second, to assess the rate of hypersensitivity and allergies in shoulder arthroplasty. Methods: Forty patients with shoulder replacements performed between 2015 and 2017 were studied with minimum 2-year follow-up; no patient had prior metal implants. Each patient underwent radiographic and clinical evaluation using the Constant-Murley Score (CMS), 22 metal and cement haptens patch testing, serum and urine tests to evaluate 12 metals concentration, and a personal occupational medicine interview. Results: At follow-up (average 45 ± 10.7 months), the mean CMS was 76 ± 15.9; no clinical complications or radiographic signs of loosening were detected; two nickel sulfate (5%), 1 benzoyl peroxide (2.5%) and 1 potassium dichromate (2.5%) positive findings were found, but all these patients were asymptomatic. There was an increase in serum aluminum, urinary aluminum and urinary chromium levels of 1.74, 3.40 and 1.83 times the baseline, respectively. No significant difference in metal ion concentrations were found when patients were stratified according to gender, date of surgery, type of surgery, and type of implant. Conclusions: Shoulder arthroplasty is a source of metal ion release and might act as a sensitizing exposure. However, patch test positivity does not seem to correlate to hypersensitivity cutaneous manifestations or poor clinical results. Laboratory data showed small constant ion release over time, regardless of gender, type of shoulder replacement and implant used. Levels of evidence: Level II.
- 1 November 2021
- Published by Springer Nature in MUSCULOSKELETAL SURGERY
- Vol. 107 (1) , 55-68
Open AccessAllergic reaction and metal hypersensitivity after shoulder joint replacement
Purpose: Metal ion release may cause local and systemic effects and induce hypersensitivity reactions. The aim of our study is first to determine if implant-related hypersensitivity correlates to patient symptoms or not; second, to assess the rate of hypersensitivity and allergies in shoulder arthroplasty. Methods: Forty patients with shoulder replacements performed between 2015 and 2017 were studied with minimum 2-year follow-up; no patient had prior metal implants. Each patient underwent radiographic and clinical evaluation using the Constant-Murley Score (CMS), 22 metal and cement haptens patch testing, serum and urine tests to evaluate 12 metals concentration, and a personal occupational medicine interview. Results: At follow-up (average 45 ± 10.7 months), the mean CMS was 76 ± 15.9; no clinical complications or radiographic signs of loosening were detected; two nickel sulfate (5%), 1 benzoyl peroxide (2.5%) and 1 potassium dichromate (2.5%) positive findings were found, but all these patients were asymptomatic. There was an increase in serum aluminum, urinary aluminum and urinary chromium levels of 1.74, 3.40 and 1.83 times the baseline, respectively. No significant difference in metal ion concentrations were found when patients were stratified according to gender, date of surgery, type of surgery, and type of implant. Conclusions: Shoulder arthroplasty is a source of metal ion release and might act as a sensitizing exposure. However, patch test positivity does not seem to correlate to hypersensitivity cutaneous manifestations or poor clinical results. Laboratory data showed small constant ion release over time, regardless of gender, type of shoulder replacement and implant used. Levels of evidence: Level II.