Nonlesional Sources of Contrast Enhancement on Postgadolinium “Black-Blood” 3D T1-SPACE Images in Patients with Multiple Sclerosis
Authors:
- L. DanieliLDL. Danieli
- L. RoccatagliataLRL. Roccatagliata
- D. DistefanoDDD. Distefano
- E. ProdiEPE. Prodi
- G.C. RiccitelliG.C. Riccitelli
- A. DiociasiADA. Diociasi
- L. CarmiscianoLCL. Carmisciano
- A. CianfoniACA. Cianfoni
- T. BartalenaTBT. Bartalena
- A. Kaelin-LangAKA. Kaelin-Lang
- C. GobbiCGC. Gobbi
- C. ZeccaCZC. Zecca
- 26 May 2022
- journal article
- research article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 43 (6) , 872-880
Abstract
BACKGROUND AND PURPOSE: We hypothesized that 3D T1-TSE “black-blood” images may carry an increased risk of contrast-enhancing lesion misdiagnosis in patients with MS because of the misinterpretation of intraparenchymal vein enhancement. Thus, the occurrence of true-positive and false-positive findings was compared between standard MPRAGE and volumetric interpolated brain examination techniques. MATERIALS AND METHODS: Sampling perfection with application-optimized contrasts by using different flip-angle evolution (SPACE) images obtained from 232 patients with MS, clinically isolated syndrome, or radiologically isolated syndrome were compared with standard MPRAGE and volumetric interpolated brain examination images. The intraparenchymal vein contrast-to-noise ratio was estimated at the level of the thalami. Contrast-enhancing lesions were blindly detected by 2 expert readers and 1 beginner reader. True- and false-positives were determined by senior readers' consensus. True-positive and false-positive frequency differences and patient-level diagnosis probability were tested with the McNemar test and OR. The contrast-to-noise ratio and morphology were compared using the Mann-Whitney U and χ2 tests. RESULTS: The intraparenchymal vein contrast-to-noise ratio was higher in SPACE than in MPRAGE and volumetric interpolated brain examination images (P < .001, both). There were 66 true-positives and 74 false-positives overall. SPACE detected more true-positive and false-positive results (P range < .001–.07) but did not increase the patient's true-positive likelihood (OR = 1 1.29, P = .478–1). However, the false-positive likelihood was increased (OR = 3.03–3.55, P = .008–.027). Venous-origin false-positives (n = 59) with contrast-to-noise ratio and morphology features similar to small-sized (≤14 mm3 P = .544) true-positives occurred more frequently in SPACE images (P < .001). CONCLUSIONS: Small intraparenchymal veins may confound the diagnosis of enhancing lesions on postgadolinium black-blood SPACE images.Keywords
Funding Information
- Scientific Research Advisory Board of the Ente Ospedaliero Cantonale (107.99501)
This publication has 37 references indexed in Scilit:
- Defining the clinical course of multiple sclerosisNeurology, 2014
- Accuracy of Postcontrast 3D Turbo Spin-Echo MR Sequence for the Detection of Enhanced Inflammatory Lesions in Patients with Multiple SclerosisAmerican Journal of Neuroradiology, 2013
- Predictors of long‐term outcome in multiple sclerosis patients treated with interferon betaAnnals of Neurology, 2013
- Radiologically isolated syndrome – incidental magnetic resonance imaging findings suggestive of multiple sclerosis, a systematic reviewMultiple Sclerosis Journal, 2012
- Association between pathological and MRI findings in multiple sclerosisThe Lancet Neurology, 2012
- Susceptibility-Weighted MR Imaging for Diagnosis of Capillary Telangiectasia of the BrainAmerican Journal of Neuroradiology, 2011
- Diagnostic criteria for multiple sclerosis: 2010 Revisions to the McDonald criteriaAnnals of Neurology, 2011
- Usefulness of Contrast-Enhanced T1-Weighted Sampling Perfection with Application-Optimized Contrasts by Using Different Flip Angle Evolutions in Detection of Small Brain Metastasis at 3T MR Imaging: Comparison with Magnetization-Prepared Rapid Acquisition of Gradient Echo ImagingAmerican Journal of Neuroradiology, 2009
- Brain Parenchymal Signal Abnormalities Associated with Developmental Venous Anomalies: Detailed MR Imaging AssessmentAmerican Journal of Neuroradiology, 2008
- Automatic delineation of Gd enhancements on magnetic resonance images in multiple sclerosisMedical Physics, 2002