LDLucia Danieli

Lucia Danieli

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lucia Danieli has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Reply

    by E. Prodi, L. Danieli, C. Manno, A. Pagnamenta, E. Pravatà, L. Roccatagliata, C. Städler, C.W. Cereda, A. Cianfoni

  • Nonlesional Sources of Contrast Enhancement on Postgadolinium “Black-Blood” 3D T1-SPACE Images in Patients with Multiple Sclerosis

    by L. Danieli, L. Roccatagliata, D. Distefano, E. Prodi, G.C. Riccitelli, A. Diociasi, L. Carmisciano, A. Cianfoni, T. Bartalena, A. Kaelin-Lang, et al.

    BACKGROUND AND PURPOSE: We hypothesized that 3D T1-TSE “black-blood” images may carry an increased risk of contrast-enhancing lesion misdiagnosis in patients with MS because of the misinterpretation of intraparenchymal vein enhancement. Thus, the occurrence of true-positive and false-positive findings was compared between standard MPRAGE and volumetric interpolated brain examination techniques. MATERIALS AND METHODS: Sampling perfection with application-optimized contrasts by using different flip-angle evolution (SPACE) images obtained from 232 patients with MS, clinically isolated syndrome, or radiologically isolated syndrome were compared with standard MPRAGE and volumetric interpolated brain examination images. The intraparenchymal vein contrast-to-noise ratio was estimated at the level of the thalami. Contrast-enhancing lesions were blindly detected by 2 expert readers and 1 beginner reader. True- and false-positives were determined by senior readers' consensus. True-positive and false-positive frequency differences and patient-level diagnosis probability were tested with the McNemar test and OR. The contrast-to-noise ratio and morphology were compared using the Mann-Whitney U and χ2 tests. RESULTS: The intraparenchymal vein contrast-to-noise ratio was higher in SPACE than in MPRAGE and volumetric interpolated brain examination images (P < .001, both). There were 66 true-positives and 74 false-positives overall. SPACE detected more true-positive and false-positive results (P range < .001–.07) but did not increase the patient's true-positive likelihood (OR = 1 1.29, P = .478–1). However, the false-positive likelihood was increased (OR = 3.03–3.55, P = .008–.027). Venous-origin false-positives (n = 59) with contrast-to-noise ratio and morphology features similar to small-sized (≤14 mm3 P = .544) true-positives occurred more frequently in SPACE images (P < .001). CONCLUSIONS: Small intraparenchymal veins may confound the diagnosis of enhancing lesions on postgadolinium black-blood SPACE images.


  • Stroke Mimics in the Acute Setting: Role of Multimodal CT Protocol

    by E. Prodi, L. Danieli, C. Manno, A. Pagnamenta, E. Pravatà, L. Roccatagliata, C. Städler, C.W. Cereda, A. Cianfoni

    BACKGROUND AND PURPOSE: Ischemic stroke can be mimicked by nonischemic conditions. Due to emphasis on the rapid treatment of acute ischemic stroke, it is crucial to identify these conditions to avoid unnecessary therapies and potential complications. We investigated the performance of the multimodal CT protocol (unenhanced brain CT, CTA, and CTP) to discriminate stroke mimics from acute ischemic stroke. MATERIALS AND METHODS: We retrospectively selected multimodal CT studies performed for clinical suspicion of acute ischemic stroke in our center in a 24-month period, including patients with at least 1 follow-up imaging study (brain CT or MR imaging). Hemorrhagic strokes were excluded. We measured the performance of multimodal CT, comparing the original diagnostic results with the final clinical diagnosis at discharge. RESULTS: Among 401 patients, a stroke mimic condition was diagnosed in 89 (22%), including seizures (34.8%), migraine with aura attack (12.4%), conversion disorder (12.4%), infection (7.9%), brain tumor (7.9%), acute metabolic condition (6.7%), peripheral vertigo (5.6%), syncope (5.6%), transient global amnesia (3.4%), subdural hematoma (1.1%), cervical epidural hematoma (1.1%), and dural AVF (1.1%). Multimodal CT sensitivity, specificity, and accuracy were 24.7%, 99.7%, and 83%. Multimodal CT revealed peri-ictal changes in 13/31 seizures and diagnosed 7/7 brain tumors, 1/1 dural AVF, and 1/1 subdural hematoma. CT perfusion played a pivotal diagnostic role. CONCLUSIONS: Multimodal CT demonstrated low sensitivity but high specificity in the diagnosis of stroke mimics in the acute setting. The high specificity of multimodal CT allows ruling out stroke and thereby avoiding unnecessary revascularization treatment in patients with diagnosis of a stroke mimic.


  • Brain Tumor-Enhancement Visualization and Morphometric Assessment: A Comparison of MPRAGE, SPACE, and VIBE MRI Techniques

    by L. Danieli, G.C. Riccitelli, D. Distefano, E. Prodi, E. Ventura, A. Cianfoni, A. Kaelin-Lang, M. Reinert, E. Pravatà

    BACKGROUND AND PURPOSE: Postgadolinium MR imaging is crucial for brain tumor diagnosis and morphometric assessment. We compared brain tumor enhancement visualization and the “target” object morphometry obtained with the most commonly used 3D MR imaging technique, MPRAGE, with 2 other routinely available techniques: sampling perfection with application-optimized contrasts by using different flip angle evolutions (SPACE) and volumetric interpolated brain examination (VIBE). MATERIALS AND METHODS: Fifty-four contrast-enhancing tumors (38 gliomas and 16 metastases) were assessed using MPRAGE, VIBE, and SPACE techniques randomly acquired after gadolinium-based contrast agent administration on a 3T scanner. Enhancement conspicuity was assessed quantitatively by calculating the contrast rate and contrast-to-noise ratio, and qualitatively, by consensus visual comparative ratings. The total enhancing tumor volume and between-sequence discrepancy in the margin delineation were assessed on the corresponding 3D target objects contoured with a computer-assisted software for neuronavigation. The Wilcoxon signed rank and Pearson χ2 nonparametric tests were used to investigate between-sequence discrepancies in the contrast rate, contrast-to-noise ratio, visual conspicuity ratings, tumor volume, and margin delineation estimates. Differences were also tested for 1D (Response Evaluation Criteria in Solid Tumors) and 2D (Response Assessment in Neuro-Oncology) measurements. RESULTS: Compared with MPRAGE, both SPACE and VIBE obtained higher contrast rate, contrast-to-noise ratio, and visual conspicuity ratings in both gliomas and metastases (P range, <.001–.001). The between-sequence 3D target object margin discrepancy ranged between 3% and 19.9% of lesion tumor volume. Larger tumor volumes, 1D and 2D measurements were obtained with SPACE (P range, <.01–.007). CONCLUSIONS: Superior conspicuity for brain tumor enhancement can be achieved using SPACE and VIBE techniques, compared with MPRAGE. Discrepancies were also detected when assessing target object size and morphology, with SPACE providing more accurate estimates.


  • Clinically Directed Neuroimaging of Ophthalmoplegia

    by Lucia Danieli, Margherita Montali, Luca Remonda, Hanspeter E. Killer, Cesare Colosimo, Alessandro Cianfoni

    Ophthalmoplegia (OP) can have numerous etiologies and different clinical presentations. Most causes of OP can be narrowed down to specific anatomical locations based on clinical information. The aim of this study was to outline the different categories of diseases encountered in patients with OP, based on the location along the ocular motor pathways, and the most appropriate imaging modality for the given scenarios.