A personalized and optimal approach for dosing contrast material at coronary computed tomography angiography
Authors:
- 1 September 2009
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2009 (1094687X) , 3521-3524
Abstract
A method for constructing a personalized contrast medium protocol at contrast enhanced, Coronary CT Angiography (CCTA) is presented. A one compartment pharmacokinetic model is parameterized and identified with a minimal data set from a test-bolus injection. A direct-search optimization is performed to construct a protocol that achieves target enhancement in the cardiac structures. Clinical results demonstrating the method's ability to achieve prospectively chosen image enhancement levels while reducing contrast medium dose are presented.Keywords
This publication has 7 references indexed in Scilit:
- Quantitative prediction of contrast enhancement from test bolus data in cardiac MSCTEuropean Radiology, 2006
- Measurement of cardiac output from a test-bolus injection in multislice computed tomographyEuropean Radiology, 2003
- Peak Contrast Enhancement in CT and MR Angiography: When Does It Occur and Why? Pharmacokinetic Study in a Porcine ModelRadiology, 2003
- The value of mathematical modelling in understanding contrast enhancement in CT with particular reference to the detection of hypovascular liver metastasesEuropean Journal of Radiology, 2002
- Mathematical Analysis of Arterial Enhancement and Optimization of Bolus Geometry for CT Angiography Using the Discrete Fourier TransformJournal of Computer Assisted Tomography, 1999
- Aortic and hepatic contrast medium enhancement at CT. Part I. Prediction with a computer model.Radiology, 1998
- Bolus dynamics: theoretical and experimental aspects.British Journal of Radiology, 1997