Abstract
Purpose: The purpose of this work is to develop machine and deep learning‐based models to predict output and MU based on measured patient quality assurance (QA) data in uniform scanning proton therapy (USPT).Methods: This study involves 4,231 patient QA measurements conducted over the last 6 years. In the current approach, output and MU are predicted by an empirical model (EM) based on patient treatment plan parameters. In this study, two MATLAB‐based machine and deep learning algorithms — Gaussian process regression (GPR) and shallow neural network (SNN) — were developed. The four parameters from patient QA (range, modulation, field size, and measured output factor) were used to train these algorithms. The data were randomized with a training set containing 90% and a testing set containing remaining 10% of the data. The model performance during training was accessed using root mean square error (RMSE) and R‐squared values. The trained model was used to predict output based on the three input parameters: range, modulation, and field size. The percent difference was calculated between the predicted and measured output factors. The number of data sets required to make prediction accuracy of GPR and SNN models' invariable was also evaluated.Results: The prediction accuracy of machine and deep learning algorithms is higher than the EM. The output predictions with [GPR, SNN, and EM] within ± 2% and ± 3% difference were [97.16%, 97.64%, and 92.95%] and [99.76%, 99.29%, and 97.18%], respectively. The GPR model outperformed the SNN with a smaller number of training data sets.Conclusion: The GPR and SNN models outperformed the EM in terms of prediction accuracy. Machine and deep learning algorithms predicted the output factor and MU for USPT with higher predictive accuracy than EM. In our clinic, these models have been adopted as a secondary check of MU or output factors.Keywords
This publication has 19 references indexed in Scilit:
- Machine Learning in Radiation Oncology: Opportunities, Requirements, and NeedsFrontiers in Oncology, 2018
- A machine learning approach to the accurate prediction of monitor units for a compact proton machineMedical Physics, 2018
- Comparability of three output prediction models for a compact passively double‐scattered proton therapy systemJournal of Applied Clinical Medical Physics, 2017
- Dosimetric advantages of proton therapy over conventional radiotherapy with photons in young patients and adults with low-grade gliomaStrahlentherapie und Onkologie, 2016
- Proton Therapy vs. VMAT for Prostate Cancer: A Treatment Planning StudyInternational Journal of Particle Therapy, 2014
- Machine learning-based patient specific prompt-gamma dose monitoring in proton therapyPhysics in Medicine & Biology, 2013
- A sector-integration method for dose/MU calculation in a uniform scanning proton beamPhysics in Medicine & Biology, 2010
- A procedure for calculation of monitor units for passively scattered proton radiotherapy beamsMedical Physics, 2008
- The prediction of output factors for spread-out proton Bragg peak fields in clinical practicePhysics in Medicine & Biology, 2005
- Monitor unit calculations for range-modulated spread-out Bragg peak fieldsPhysics in Medicine & Biology, 2003