Abstract
Quantitative flow measurements with volumetric coverage and three directional flow encoding are technically feasible with magnetic resonance imaging yet prohibitively long in clinical settings. Data reconstruction from three dimensional angular undersampled MR acquisitions allows for dramatic reductions in scan time with tolerable imaging artifacts in many clinical applications. This approach provides high spatial resolution suitable for hemodynamic analysis in smaller vessels such as the renal artery, thereby providing additional crucial diagnostic information in a non invasive fashion. In an animal model, transstenotic pressure gradient measurements obtained with the novel acquisition scheme compared favorably with invasive intra arterial measurements (r = 3D 0.977; 95% CI: 0.931-0.998; p < 0.001). In addition, human studies demonstrate the suitability of the technique for lumen measurements as an alternative for contrast enhanced MR angiography and the associated risks with the use of an external contrast agent in certain patient populations.Keywords
This publication has 9 references indexed in Scilit:
- Improved 3D phase contrast MRI with off‐resonance corrected dual echo VIPRMagnetic Resonance in Medicine, 2008
- Is there a causal relation between the administration of gadolinium based contrast media and the development of nephrogenic systemic fibrosis (NSF)?Clinical Radiology, 2006
- Generation and visualization of four-dimensional MR angiography data using an undersampled 3-D projection trajectoryIEEE Transactions on Medical Imaging, 2006
- Fast measurement of intracardiac pressure differences with 2D breath‐hold phase‐contrast MRIMagnetic Resonance in Medicine, 2003
- Cardiovascular Flow Measurement with Phase-Contrast MR Imaging: Basic Facts and ImplementationRadioGraphics, 2002
- Three-dimensional, time-resolved (4D) relative pressure mapping using magnetic resonance imagingJournal of Magnetic Resonance Imaging, 2000
- Temporally resolved 3D phase‐contrast imagingMagnetic Resonance in Medicine, 1996
- Selection of a convolution function for Fourier inversion using gridding (computerised tomography application)IEEE Transactions on Medical Imaging, 1991