Preliminary Results from Electron Cyclotron Measurements at SST-1
Authors:
Open Access
- 19 April 2017
- conference paper
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 823 (1) , 012057
Abstract
An 8-channel heterodyne radiometer system is developed and installed for the measurements of second harmonic electron cyclotron emission (ECE) at magnetic field of 1.5 T at SST-1. This system covers a spectral range of 75.4 to 84.5 GHz at a spatial resolution of less than 1 cm, sensitivity of 9.51 x 106 V/W. The calculated noise temperature of the system is 1.66 eV. The system is calibrated using Hot/cold technique. This paper presents the preliminary observations of the heterodyne radiometer system at SST-1 and the measured radiation temperature.Keywords