Varsha Siju
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Varsha Siju has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
J. Ghosh
Institute for Plasma Research, Bhat, Gandhinagar – 382 428
3 shared publicationsS. K. Pathak
Inst Plasma Res, Gandhinagar 382428, India
3 shared publicationsK. Tahiliani
Inst Plasma Res, Gandhinagar 382428, India
2 shared publicationsR. Kumar
Institute for Plasma Research, Bhat, Gandhinagar – 382 428
2 shared publicationsR. L. Tanna
Inst Plasma Res, Gandhinagar 382428, India
2 shared publicationsR.L. Tanna
Institute for Plasma Research, Bhat, Gandhinagar – 382 428
2 shared publications
Latest Publications
- 1 November 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (11) , P11008
Performance evaluation of a D-band (130–170 GHz) heterodyne receiver front-end for radiometric applications
The performance of a millimeter-wave radiometer is strongly influenced by the characteristics of its radio-frequency (RF) front-end, making comprehensive experimental characterization essential prior to system deployment. This work presents the characterization methodology and performance evaluation of a commercially available D-band heterodyne receiver front-end operating over the 130–170 GHz frequency range. The study investigates the performance of the principal passive and active microwave components, including IMPATT local oscillators, balanced mixers, high-pass filters, cavity band-pass filters, isolators, directional couplers, and the calibration noise source, followed by evaluation of the integrated receiver front-end and its interface with an 8-channel intermediate-frequency (IF) receiver covering 1–20 GHz. The 130 GHz and 150 GHz IMPATT oscillators were characterized in terms of output power, phase noise, frequency stability, and short-term frequency drift. The balanced mixers exhibited an average conversion loss of approximately 9 dB while providing down-conversion from the 130–170 GHz RF band to a 1–20 GHz IF. Passive microwave components were evaluated through measurements of insertion loss, isolation, coupling characteristics, and transmission response, while a calibrated noise source with manufacturer-specified excess noise ratio (ENR) values was used as part of the receiver characterisation procedure.The complete receiver chain was subsequently validated through RF-to-IF measurements using an 8-channel IF receiver. The experimental results establish the performance of the individual receiver components as well as the integrated front-end architecture, demonstrating its suitability for high-sensitivity millimeter-wave radiometry and electron cyclotron emission diagnostic applications. The characterization methodology presented in this work also provides a practical framework for the evaluation and integration of D-band heterodyne receiver systems.
- 1 November 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (11) , P11008
Performance evaluation of a D-band (130–170 GHz) heterodyne receiver front-end for radiometric applications
The performance of a millimeter-wave radiometer is strongly influenced by the characteristics of its radio-frequency (RF) front-end, making comprehensive experimental characterization essential prior to system deployment. This work presents the characterization methodology and performance evaluation of a commercially available D-band heterodyne receiver front-end operating over the 130–170 GHz frequency range. The study investigates the performance of the principal passive and active microwave components, including IMPATT local oscillators, balanced mixers, high-pass filters, cavity band-pass filters, isolators, directional couplers, and the calibration noise source, followed by evaluation of the integrated receiver front-end and its interface with an 8-channel intermediate-frequency (IF) receiver covering 1–20 GHz. The 130 GHz and 150 GHz IMPATT oscillators were characterized in terms of output power, phase noise, frequency stability, and short-term frequency drift. The balanced mixers exhibited an average conversion loss of approximately 9 dB while providing down-conversion from the 130–170 GHz RF band to a 1–20 GHz IF. Passive microwave components were evaluated through measurements of insertion loss, isolation, coupling characteristics, and transmission response, while a calibrated noise source with manufacturer-specified excess noise ratio (ENR) values was used as part of the receiver characterisation procedure.The complete receiver chain was subsequently validated through RF-to-IF measurements using an 8-channel IF receiver. The experimental results establish the performance of the individual receiver components as well as the integrated front-end architecture, demonstrating its suitability for high-sensitivity millimeter-wave radiometry and electron cyclotron emission diagnostic applications. The characterization methodology presented in this work also provides a practical framework for the evaluation and integration of D-band heterodyne receiver systems.
- 1 July 2026
- Published by AIP Publishing in Physics of Plasmas
- Vol. 33 (7)
Lower hybrid wave-driven non-thermal electron-generated hard x rays from ADITYA-U tokamak: Measurement and modeling study through synthetic diagnostics
Lower hybrid (LH) power at 3.7 GHz was injected into the ADITYA-U tokamak marking the first implementation of the LH current drive on this device using a newly installed passive-active multi-junction launcher. Initial experiments achieved 80–100 kW of LH power coupling, leading to the formation of a high-energy tail in the plasma's electron energy distribution that shows a clear signature of suprathermal electrons driven by the LH waves. Bremsstrahlung emission is identified as a primary diagnostic tool for measuring these non-thermal electrons. Integrated ray tracing and Fokker–Planck simulations using the GENRAY and CQL3D has been applied to interpret the LH current drive experiments on ADITYA-U for the first time. The parametric variation of density, temperature, effective ion charge, and the coefficient of radial diffusion has been performed numerically to study the effect on the energy spectrum of bremsstrahlung emission due to the LH-driven suprathermal or fast electrons. These simulations incorporate experimentally measured parameters to model the LH wave propagation (in GENRAY) and wave–particle interactions (in CQL3D). The Fokker–Planck solver quantifies the momentum transfer from LH waves to electrons, resolving the equilibrium electron distribution function shaped by quasi-linear diffusion and collisional effects. A synthetic diagnostic module calculates the resulting bremsstrahlung emission and the pulse-height hard x-ray (HXR) spectrum as measured by a single-channel detection system. A detailed comparison between the simulated HXR spectrum and measurements from a cadmium telluride detector, shows reasonable agreement. These results provide a validated framework for interpreting the LH-driven fast electron dynamics in ADITYA-U and support future experimental and modeling studies.
- 1 July 2026
- Published by AIP Publishing in Physics of Plasmas
- Vol. 33 (7)
Lower hybrid wave-driven non-thermal electron-generated hard x rays from ADITYA-U tokamak: Measurement and modeling study through synthetic diagnostics
Lower hybrid (LH) power at 3.7 GHz was injected into the ADITYA-U tokamak marking the first implementation of the LH current drive on this device using a newly installed passive-active multi-junction launcher. Initial experiments achieved 80–100 kW of LH power coupling, leading to the formation of a high-energy tail in the plasma's electron energy distribution that shows a clear signature of suprathermal electrons driven by the LH waves. Bremsstrahlung emission is identified as a primary diagnostic tool for measuring these non-thermal electrons. Integrated ray tracing and Fokker–Planck simulations using the GENRAY and CQL3D has been applied to interpret the LH current drive experiments on ADITYA-U for the first time. The parametric variation of density, temperature, effective ion charge, and the coefficient of radial diffusion has been performed numerically to study the effect on the energy spectrum of bremsstrahlung emission due to the LH-driven suprathermal or fast electrons. These simulations incorporate experimentally measured parameters to model the LH wave propagation (in GENRAY) and wave–particle interactions (in CQL3D). The Fokker–Planck solver quantifies the momentum transfer from LH waves to electrons, resolving the equilibrium electron distribution function shaped by quasi-linear diffusion and collisional effects. A synthetic diagnostic module calculates the resulting bremsstrahlung emission and the pulse-height hard x-ray (HXR) spectrum as measured by a single-channel detection system. A detailed comparison between the simulated HXR spectrum and measurements from a cadmium telluride detector, shows reasonable agreement. These results provide a validated framework for interpreting the LH-driven fast electron dynamics in ADITYA-U and support future experimental and modeling studies.
- Open Access
- 15 November 2024
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 313, 03002
Recent Results from Electron Cyclotron Emission (ECE) Radiometer diagnostics in the presence of Electron Cyclotron Resonance Heating (ECRH)
Besides furnishing localized spatial and temporal electron temperature measurements, Electron Cyclotron Emission (ECE) diagnostics are routinely employed across various tokamaks for diverse physics investigations, encompassing MHD localizations, transport studies, and fluctuation measurements. Variations in the bulk of the electron distribution function manifest as alterations in ECE signatures, often attributable to the presence of fast electrons induced by auxiliary heating mechanisms such as Electron Cyclotron Resonance Heating (ECRH). This manuscript delves into the scrutiny of such interactions on ECE spectra leveraging a newly devised 16-channel ECE radiometer diagnostic. The manuscript delineates the impact of ECRH application, including pre-ionization and heating, resulting in ECE signal saturation and an expected rise in electron temperature (Te) respectively. Furthermore, the discourse explores instabilities potentially induced by high-energy electrons stemming from ECRH, focusing initial observations on runaway discharges characterized by relaxation oscillations in ECE, Soft X-ray (SXR), CIII, and Hα emissions. The backdrop of weakly ionized plasma with low electron density (ne) and temperature (Te), coupled with ECRH, fosters the generation of runaway electrons and corresponding relaxation oscillations in bulk plasma parameters. Additionally, a distinct surge in the ECE signature emerges upon cessation of the ECRH pulse, with no discernible variation in other bulk plasma parameters. Given that ECE signatures are susceptible to changes in both energy and pitch angle, this abrupt amplitude rise likely arises from Pitch Angle Scattering (PAS), potentially prompted by the sudden de-acceleration of fast electrons engendered by the ECRH pulse.
- 15 November 2024
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 313, 03002
Open AccessRecent Results from Electron Cyclotron Emission (ECE) Radiometer diagnostics in the presence of Electron Cyclotron Resonance Heating (ECRH)
Besides furnishing localized spatial and temporal electron temperature measurements, Electron Cyclotron Emission (ECE) diagnostics are routinely employed across various tokamaks for diverse physics investigations, encompassing MHD localizations, transport studies, and fluctuation measurements. Variations in the bulk of the electron distribution function manifest as alterations in ECE signatures, often attributable to the presence of fast electrons induced by auxiliary heating mechanisms such as Electron Cyclotron Resonance Heating (ECRH). This manuscript delves into the scrutiny of such interactions on ECE spectra leveraging a newly devised 16-channel ECE radiometer diagnostic. The manuscript delineates the impact of ECRH application, including pre-ionization and heating, resulting in ECE signal saturation and an expected rise in electron temperature (Te) respectively. Furthermore, the discourse explores instabilities potentially induced by high-energy electrons stemming from ECRH, focusing initial observations on runaway discharges characterized by relaxation oscillations in ECE, Soft X-ray (SXR), CIII, and Hα emissions. The backdrop of weakly ionized plasma with low electron density (ne) and temperature (Te), coupled with ECRH, fosters the generation of runaway electrons and corresponding relaxation oscillations in bulk plasma parameters. Additionally, a distinct surge in the ECE signature emerges upon cessation of the ECRH pulse, with no discernible variation in other bulk plasma parameters. Given that ECE signatures are susceptible to changes in both energy and pitch angle, this abrupt amplitude rise likely arises from Pitch Angle Scattering (PAS), potentially prompted by the sudden de-acceleration of fast electrons engendered by the ECRH pulse.
- 1 November 2024
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 26 (11) , 115101
Investigating the occurrence and predictability of pitch angle scattering events at ADITYA-Upgrade tokamak with the electron cyclotron emission radiometer
This paper describes the experimental analysis and preliminary investigation of the predictability of pitch angle scattering (PAS) events through the electron cyclotron emission (ECE) radiometer signals at the ADITYA-Upgrade (ADITYA-U) tokamak. For low-density discharges at ADITYA-U, a sudden abnormal rise is observed in the ECE signature while other plasma parameters are unchanged. Investigations are done to understand this abrupt rise that is expected to occur due to PAS. The rise time is as fast as 100 μs with a single step and/or multiple step rise in ECE radiometer measurements. This event is known to limit the on-axis energy of runaway electrons. Being a repetitive event, the conditions of its repetitive occurrence can be investigated, thereby exploring the possibility of it being triggered and surveyed as an alternate runaway electron mitigation plan. Functional parameterization of such events with other discharge parameters is obtained and the possibility to trigger these events is discussed. PREDICT code is used to investigate the possible interpretations for the PAS occurrence through modeling and supporting the ECE observations. The trigger values so obtained experimentally are set as input criteria for PAS occurrence. Preliminary modeling investigations provide reliable consistency with the findings.
- 1 November 2024
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 26 (11) , 115101
Investigating the occurrence and predictability of pitch angle scattering events at ADITYA-Upgrade tokamak with the electron cyclotron emission radiometer
This paper describes the experimental analysis and preliminary investigation of the predictability of pitch angle scattering (PAS) events through the electron cyclotron emission (ECE) radiometer signals at the ADITYA-Upgrade (ADITYA-U) tokamak. For low-density discharges at ADITYA-U, a sudden abnormal rise is observed in the ECE signature while other plasma parameters are unchanged. Investigations are done to understand this abrupt rise that is expected to occur due to PAS. The rise time is as fast as 100 μs with a single step and/or multiple step rise in ECE radiometer measurements. This event is known to limit the on-axis energy of runaway electrons. Being a repetitive event, the conditions of its repetitive occurrence can be investigated, thereby exploring the possibility of it being triggered and surveyed as an alternate runaway electron mitigation plan. Functional parameterization of such events with other discharge parameters is obtained and the possibility to trigger these events is discussed. PREDICT code is used to investigate the possible interpretations for the PAS occurrence through modeling and supporting the ECE observations. The trigger values so obtained experimentally are set as input criteria for PAS occurrence. Preliminary modeling investigations provide reliable consistency with the findings.
- 1 November 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (11) , 113529
Investigating the effect of density variation on pitch angle scattering events of runaway electrons as observed through electron cyclotron emission diagnostic at Aditya-upgrade tokamak
Nascent observations about the influence of kinetic instabilities on electron cyclotron emission (ECE) from runaway electrons (REs) have been detected and explored at the Aditya-Upgrade (Aditya-U) tokamak. The developed broadband ECE radiometer system offers wideband measurements by integrating several radio frequency units with a fixed intermediate frequency receiver with multiple channels, which is a novel approach to meet the needs of the localized measurements at various toroidal fields and extend the system dynamic range. The low density (ne ≤ 1 × 10−19 m−3) plasma discharges at Aditya-U are consistently accompanied by a 20%–40% increase in the ECE radiometer signal amplitude within 100 µs and sporadic step-like modulations. The Pitch Angle Scattering (PAS) of REs induced by kinetic instabilities is a potential candidate for their occurrence. This steep jump in the radiometer signals was detected due to its high temporal resolution of 10 µs. A “PREDICT” code that employs the relativistic test particle model validates these experimental findings of the radiometer diagnostic for the first time for Aditya-U tokamak. Preliminary observations of the ECE radiometer signals also show that additional gas puffs can be used to vary the trigger timings of such PAS events or even lead to their complete avoidance.
- 1 November 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (11) , 113529
Investigating the effect of density variation on pitch angle scattering events of runaway electrons as observed through electron cyclotron emission diagnostic at Aditya-upgrade tokamak
Nascent observations about the influence of kinetic instabilities on electron cyclotron emission (ECE) from runaway electrons (REs) have been detected and explored at the Aditya-Upgrade (Aditya-U) tokamak. The developed broadband ECE radiometer system offers wideband measurements by integrating several radio frequency units with a fixed intermediate frequency receiver with multiple channels, which is a novel approach to meet the needs of the localized measurements at various toroidal fields and extend the system dynamic range. The low density (ne ≤ 1 × 10−19 m−3) plasma discharges at Aditya-U are consistently accompanied by a 20%–40% increase in the ECE radiometer signal amplitude within 100 µs and sporadic step-like modulations. The Pitch Angle Scattering (PAS) of REs induced by kinetic instabilities is a potential candidate for their occurrence. This steep jump in the radiometer signals was detected due to its high temporal resolution of 10 µs. A “PREDICT” code that employs the relativistic test particle model validates these experimental findings of the radiometer diagnostic for the first time for Aditya-U tokamak. Preliminary observations of the ECE radiometer signals also show that additional gas puffs can be used to vary the trigger timings of such PAS events or even lead to their complete avoidance.
- 1 October 2021
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 16 (10) , P10020
Design and characterization of radiometer system for electron cyclotron measurements at Aditya-Upgrade tokamak
Instrumentation and characterization techniques have been developed for a 16-channel radiometer system to obtain localized electron cyclotron emission (ECE) measurements at Aditya-Upgrade tokamak. Inverse dependence of the EC radiation on the toroidal magnetic field constrains the hardware for measurements at a fixed radial location. This results in having costly and complex sweep systems or use of multiple receiver units dedicated to a specific toroidal magnetic field. A simple, cost effective solution to this issue could be using a fixed frequency wideband intermediate frequency (IF) receiver. This multiple channel hardware unit can do localized measurements at fixed as well as different magnetic fields thereby improving the measurement range. Designed system provides a spatial resolution of 1.2 cm and a temporal resolution of 10 μs.Noise figure of the system varies from 15–22 dB while the sensitivity is 0.1 × 106 V/W. The manuscript provides an insight over the characterization techniques followed for the design of the radiometer system. A brief overview of the calibration technique is discussed. First measurements obtained from the system are also presented.
- 1 October 2021
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 16 (10) , P10020
Design and characterization of radiometer system for electron cyclotron measurements at Aditya-Upgrade tokamak
Instrumentation and characterization techniques have been developed for a 16-channel radiometer system to obtain localized electron cyclotron emission (ECE) measurements at Aditya-Upgrade tokamak. Inverse dependence of the EC radiation on the toroidal magnetic field constrains the hardware for measurements at a fixed radial location. This results in having costly and complex sweep systems or use of multiple receiver units dedicated to a specific toroidal magnetic field. A simple, cost effective solution to this issue could be using a fixed frequency wideband intermediate frequency (IF) receiver. This multiple channel hardware unit can do localized measurements at fixed as well as different magnetic fields thereby improving the measurement range. Designed system provides a spatial resolution of 1.2 cm and a temporal resolution of 10 μs.Noise figure of the system varies from 15–22 dB while the sensitivity is 0.1 × 106 V/W. The manuscript provides an insight over the characterization techniques followed for the design of the radiometer system. A brief overview of the calibration technique is discussed. First measurements obtained from the system are also presented.
- 1 December 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (12) , 124703
Application of automatic gain control for radiometer diagnostic in SST-1 tokamak
This paper describes the characterisation of a negative feedback type of automatic gain control (AGC) circuit that will be an integral part of the heterodyne radiometer system operating at a frequency range of 75–86 GHz at SST-1 tokamak. The developed AGC circuit is a combination of variable gain amplifier and log amplifier which provides both gain and attenuation typically up to 15 dB and 45 dB, respectively, at a fixed set point voltage and it has been explored for the first time in tokamak radiometry application. The other important characteristics are that it exhibits a very fast response time of 390 ns to understand the fast dynamics of electron cyclotron emission and can operate at very wide input RF power dynamic range of around 60 dB that ensures signal level within the dynamic range of the detection system.
- 1 December 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (12) , 124703
Application of automatic gain control for radiometer diagnostic in SST-1 tokamak
This paper describes the characterisation of a negative feedback type of automatic gain control (AGC) circuit that will be an integral part of the heterodyne radiometer system operating at a frequency range of 75–86 GHz at SST-1 tokamak. The developed AGC circuit is a combination of variable gain amplifier and log amplifier which provides both gain and attenuation typically up to 15 dB and 45 dB, respectively, at a fixed set point voltage and it has been explored for the first time in tokamak radiometry application. The other important characteristics are that it exhibits a very fast response time of 390 ns to understand the fast dynamics of electron cyclotron emission and can operate at very wide input RF power dynamic range of around 60 dB that ensures signal level within the dynamic range of the detection system.
- Open Access
- 19 April 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 823 (1) , 012057
Preliminary Results from Electron Cyclotron Measurements at SST-1
An 8-channel heterodyne radiometer system is developed and installed for the measurements of second harmonic electron cyclotron emission (ECE) at magnetic field of 1.5 T at SST-1. This system covers a spectral range of 75.4 to 84.5 GHz at a spatial resolution of less than 1 cm, sensitivity of 9.51 x 106 V/W. The calculated noise temperature of the system is 1.66 eV. The system is calibrated using Hot/cold technique. This paper presents the preliminary observations of the heterodyne radiometer system at SST-1 and the measured radiation temperature.
- 19 April 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 823 (1) , 012057
Open AccessPreliminary Results from Electron Cyclotron Measurements at SST-1
An 8-channel heterodyne radiometer system is developed and installed for the measurements of second harmonic electron cyclotron emission (ECE) at magnetic field of 1.5 T at SST-1. This system covers a spectral range of 75.4 to 84.5 GHz at a spatial resolution of less than 1 cm, sensitivity of 9.51 x 106 V/W. The calculated noise temperature of the system is 1.66 eV. The system is calibrated using Hot/cold technique. This paper presents the preliminary observations of the heterodyne radiometer system at SST-1 and the measured radiation temperature.