Robotic-assisted pedicle screw placement achieves high accuracy and narrows the experience gap: a preclinical evaluation
Authors:
Open Access
- 1 June 2026
- journal article
- research article
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1)
Abstract
To assess a robotic-assisted system versus open manual techniques to: (1) compare pedicle screw accuracy between fellows and attendings with and without robotic assistance, and (2) evaluate executed versus planned trajectory fidelity relative to prior reports. Robotic-assisted spine systems aim to improve the accuracy, reproducibility, and safety of pedicle screw placement. Limited evidence compares outcomes across differing surgeon experience levels. A total of 255 thoracolumbar pedicle screws were placed in synthetic torsos simulating adult degenerative anatomy. Four surgeons (two fellows, two attendings) each placed half their screws using open fluoroscopy-guided techniques and half using a minimally invasive percutaneous approach with the Mako Spine system and intraoperative CT-based planning. Postoperative CT and the Gertzbein-Robbins classification were used to assess accuracy. Optimal placement (Grade A), breach rates, and positional/angular deviation from planned trajectories were recorded. The robotic cohort achieved a higher rate of clinically acceptable screw placement compared with the manual cohort, although this difference was not statistically significant (124/127, 97.6% vs. 120/128, 93.8%; P = 0.223). Fellows and attendings both achieved high clinically acceptable screw placement rates using robotics (63/64, 98.4% vs. 61/63, 96.8%). Among fellows, robotic assistance increased optimal screw placement compared with the manual technique (53/64, 82.8% vs. 41/64, 64.1%; P < 0.05). Robotic screws demonstrated low mean deviations from planned trajectories (1.4 ± 0.9 mm positional, 1.7 ± 1.1° angular). The Mako Spine system enabled precise screw placement and narrowed performance gaps for less experienced surgeons. It shows promise as both training tool and means to standardize outcomes.Keywords
All Related Versions
This publication has 24 references indexed in Scilit:
- Robotic-assisted spine surgery allows for increased pedicle screw sizes while still improving safety as indicated by elevated triggered electromyographic thresholdsJournal of Robotic Surgery, 2022
- Factors Affecting the Accuracy of Pedicle Screw Placement in Robot-Assisted SurgerySpine, 2022
- Navigated robotic assistance improves pedicle screw accuracy in minimally invasive surgery of the lumbosacral spine: 600 pedicle screws in a single institutionThe International Journal of Medical Robotics and Computer Assisted Surgery, 2019
- Navigated robot-guided pedicle screws placed successfully in single-position lateral lumbar interbody fusionJournal of Robotic Surgery, 2019
- Does the accuracy of pedicle screw placement differ between the attending surgeon and resident in navigated robotic-assisted minimally invasive spine surgery?Journal of Robotic Surgery, 2019
- Navigated robotic assistance results in improved screw accuracy and positive clinical outcomes: an evaluation of the first 54 casesJournal of Robotic Surgery, 2019
- Pedicle screw accuracy in clinical utilization of minimally invasive navigated robot-assisted spine surgeryJournal of Robotic Surgery, 2019
- Robotic-assisted navigated minimally invasive pedicle screw placement in the first 100 cases at a single institutionJournal of Robotic Surgery, 2019
- First spine surgery utilizing real-time image-guided robotic assistanceComputer Assisted Surgery, 2019
- Accuracy of Pedicular Screw Placement In VivoSpine, 1990