Abstract
In the emerging field of robot-assisted spine surgery, the radiographic evaluation of pedicle screw accuracy in clinical application is an area of high interest. This study describes the pedicle screw accuracy of the first 56 consecutive cases in which navigated robotic assistance was used in a private practice clinical setting. A retrospective, Institutional Review Board-exempt review of the first 56 navigated robot-assisted spine surgery cases was performed. Pedicle screw malposition, reposition, and return to operating room (OR) rates were collected. A CT-based Gertzbein and Robbins system (GRS) was used to classify pedicle screw accuracy. In the first 56 robotic cases, 356 total pedicle screws were placed. Eight screws were placed without the robot due to surgeon discretion. Of the 348 pedicle screws inserted by navigated robotic guidance, only 2.6% (9/348) were repositioned, resulting in a 97.4% (339/348) successful screw placement rate. The average age was 64, and 48% were female. Average body mass index was 31 kg/m2. Based on the GRS CT-based grading, 97.7% (340/348) were graded A or B, 1.7% (6/348) screws were graded C, and only 0.6% (2/348) of screws were graded D. Two complications, explantation of interbody and vacuum-assisted wound closure, were reported as requiring a return to the OR, but these were not related to robotic guidance or pedicle screws. This study demonstrated a high level of accuracy (97.7%) in the first 56 cases using navigated, robot-assisted surgery based on the GRS. There were two non-screw-related complications requiring return to the operating room.Keywords
This publication has 20 references indexed in Scilit:
- The Arrival of Robotics in Spine SurgerySpine, 2018
- Computer navigation versus fluoroscopy-guided navigation for thoracic pedicle screw placement: a meta-analysisNeurosurgical Review, 2015
- Pelvic Fixation in Adult and Pediatric Spine Surgery: Historical Perspective, Indications, and TechniquesJournal of Bone and Joint Surgery, 2015
- A Prospective Multicenter Registry on the Accuracy of Pedicle Screw Placement in the Thoracic, Lumbar, and Sacral Levels With the Use of the O-arm Imaging System and StealthStation NavigationSpine, 2012
- Pedicle screw navigation: a systematic review and meta-analysis of perforation risk for computer-navigated versus freehand insertionJournal of Neurosurgery: Spine, 2012
- Pediatric Pedicle Screws: Comparative Effectiveness and SafetyJournal of Bone and Joint Surgery, 2011
- Accuracy of Free-Hand Pedicle Screws in the Thoracic and Lumbar Spine: Analysis of 6816 Consecutive ScrewsNeurosurgery, 2011
- Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studiesEuropean Spine Journal, 2010
- Complications of Pedicle Screw Fixation in Scoliosis SurgerySpine, 2010
- Free Hand Pedicle Screw Placement in the Thoracic Spine: Is it Safe?Spine, 2004