Abstract
Junction temperature (Tj) monitoring using thermal sensitive electrical parameters (TSEPs) has been widely investigated. However, most TSEPs are susceptible to aging effects, making the decoupling of Tj and aging a critical challenge for the online condition monitoring of power modules. Based on the chip structural characteristics of MOSFETs, this letter proposes a novel TSEP to achieve decoupling of Tj and bond-wire aging. To this end, a dual-sampling and modulation strategy synchronized with the zero-vector is presented to achieve non-intrusive online measurement. The proposed decoupling method features a clear physical interpretation and an analytical model. Experimental results demonstrate that, for Tj monitoring, the proposed method is insensitive to bond-wire aging and achieves higher accuracy over the full operating range. For aging assessment, it enables converter-level online identification of bond-wire aging states.
Funding Information
  • National Key R&D Program of China (2021YFB2500600)
  • china state railway group co., ltd. (L2025J002)

This publication has 8 references indexed in Scilit: