Xuhui Wen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Xuhui Wen has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Tao Fan
University of Chinese Academy of Sciences
3 shared publications - Dan Zheng
Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing, China
2 shared publications - Dong Zhang
Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing, China
2 shared publications Hongyang Li
Chinese Academy of Sciences
2 shared publications- Puqi Ning
School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, China
2 shared publications Chengxu Sun
Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing, China
1 shared publication
Latest Publications
- 4 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. PP (08858993) , 1-5
Decoupling Method for Simultaneous Online Tj and Bond-Wire Aging Monitoring of SiC MOSFETs
Junction temperature (Tj) monitoring using thermal sensitive electrical parameters (TSEPs) has been widely investigated. However, most TSEPs are susceptible to aging effects, making the decoupling of Tj and aging a critical challenge for the online condition monitoring of power modules. Based on the chip structural characteristics of MOSFETs, this letter proposes a novel TSEP to achieve decoupling of Tj and bond-wire aging. To this end, a dual-sampling and modulation strategy synchronized with the zero-vector is presented to achieve non-intrusive online measurement. The proposed decoupling method features a clear physical interpretation and an analytical model. Experimental results demonstrate that, for Tj monitoring, the proposed method is insensitive to bond-wire aging and achieves higher accuracy over the full operating range. For aging assessment, it enables converter-level online identification of bond-wire aging states.
- 4 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. PP (08858993) , 1-5
Decoupling Method for Simultaneous Online Tj and Bond-Wire Aging Monitoring of SiC MOSFETs
Junction temperature (Tj) monitoring using thermal sensitive electrical parameters (TSEPs) has been widely investigated. However, most TSEPs are susceptible to aging effects, making the decoupling of Tj and aging a critical challenge for the online condition monitoring of power modules. Based on the chip structural characteristics of MOSFETs, this letter proposes a novel TSEP to achieve decoupling of Tj and bond-wire aging. To this end, a dual-sampling and modulation strategy synchronized with the zero-vector is presented to achieve non-intrusive online measurement. The proposed decoupling method features a clear physical interpretation and an analytical model. Experimental results demonstrate that, for Tj monitoring, the proposed method is insensitive to bond-wire aging and achieves higher accuracy over the full operating range. For aging assessment, it enables converter-level online identification of bond-wire aging states.
- 2 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP (21686777) , 1
A 400-kW Integrated Modular Machine Drive for Electrified Transportation: Architecture, Thermal Management, and EMI Filtering
The rapid electrification of transportation demands motor drive systems with high power density, high efficiency, and exceptional reliability. In this paper, the design and experimental validation of an 18-phase, 400-kW Integrated Modular Machine Drive (IMMD) system is presented. The architecture features deep integration of an open-end winding motor with single-phase full-bridge Silicon Carbide (SiC) inverters, forming 18 structurally and electrically decoupled modules that enable independent control, fault isolation, and rapid maintenance. Key innovations include a custom 1200-V/160-A stacked direct-bonded-copper (DBC) SiC power module with reduced parasitic inductance, and an ultra-conducting copper winding conductor incorporating an in-situ 3D graphene network to simultaneously enhance electrical conductivity, thermal conductivity, and mechanical strength. Both inverter and motor modules employ PINFIN-based direct liquid cooling, with thermal simulations confirming that hotspot temperatures remain below material limits under rated operation. A hybrid feedforward–feedback active EMI filter is proposed to suppress low-frequency common-mode (CM) interference, achieving significant attenuation in the 20 kHz–500 kHz band. Experimental results from single-module full-load and three-phase coordinated tests validate the design feasibility and performance predictions. The developed IMMD system demonstrates a viable pathway toward highly reliable, compact, and serviceable electric drive systems for next-generation electrified transportation.
- 2 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP (21686777) , 1
A 400-kW Integrated Modular Machine Drive for Electrified Transportation: Architecture, Thermal Management, and EMI Filtering
The rapid electrification of transportation demands motor drive systems with high power density, high efficiency, and exceptional reliability. In this paper, the design and experimental validation of an 18-phase, 400-kW Integrated Modular Machine Drive (IMMD) system is presented. The architecture features deep integration of an open-end winding motor with single-phase full-bridge Silicon Carbide (SiC) inverters, forming 18 structurally and electrically decoupled modules that enable independent control, fault isolation, and rapid maintenance. Key innovations include a custom 1200-V/160-A stacked direct-bonded-copper (DBC) SiC power module with reduced parasitic inductance, and an ultra-conducting copper winding conductor incorporating an in-situ 3D graphene network to simultaneously enhance electrical conductivity, thermal conductivity, and mechanical strength. Both inverter and motor modules employ PINFIN-based direct liquid cooling, with thermal simulations confirming that hotspot temperatures remain below material limits under rated operation. A hybrid feedforward–feedback active EMI filter is proposed to suppress low-frequency common-mode (CM) interference, achieving significant attenuation in the 20 kHz–500 kHz band. Experimental results from single-module full-load and three-phase coordinated tests validate the design feasibility and performance predictions. The developed IMMD system demonstrates a viable pathway toward highly reliable, compact, and serviceable electric drive systems for next-generation electrified transportation.
- 24 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
An Improved Method for Inverter-Fed Motor Insulation Online Condition Monitoring by High-Frequency Leakage Current Analysis
Insulation degradation is an important cause of inverter-fed motor failures. In order to improve the safety of electric motor systems and to avoid sudden failures, timely monitoring of motor insulation degradation is necessary. The high-frequency common-mode leakage current flowing through the groundwall insulation reflects the degradation of the groundwall insulation, especially that of the first few turns. In this paper, an insulation condition monitoring method based on leakage current is proposed. An improved common-mode model of the winding suitable for leakage current analysis is proposed, based on the characteristics of the common-mode impedance curve of the motor. By analyzing the mathematical relationship between high-frequency leakage current and insulation degradation in the first few turns, the insulation condition indicators are proposed, and it is validated by the experimental results. Based on this method, a suite of hardware for pre-processing leakage current waveforms is designed, thus providing a cost-effective insulation monitoring method that minimises both hardware and software requirements.
- 24 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
An Improved Method for Inverter-Fed Motor Insulation Online Condition Monitoring by High-Frequency Leakage Current Analysis
Insulation degradation is an important cause of inverter-fed motor failures. In order to improve the safety of electric motor systems and to avoid sudden failures, timely monitoring of motor insulation degradation is necessary. The high-frequency common-mode leakage current flowing through the groundwall insulation reflects the degradation of the groundwall insulation, especially that of the first few turns. In this paper, an insulation condition monitoring method based on leakage current is proposed. An improved common-mode model of the winding suitable for leakage current analysis is proposed, based on the characteristics of the common-mode impedance curve of the motor. By analyzing the mathematical relationship between high-frequency leakage current and insulation degradation in the first few turns, the insulation condition indicators are proposed, and it is validated by the experimental results. Based on this method, a suite of hardware for pre-processing leakage current waveforms is designed, thus providing a cost-effective insulation monitoring method that minimises both hardware and software requirements.